Warm-Up 250 to 650 degrees

During catalyst temperatures in this range, your monitor displays temperatures in 50-degree increments. 
Some up-and-down readings are normal.

 At steady 500 degrees or higher,  your ceramic catalytic 

combustor can be engaged

. Close the bypass and your catalyst will give you added heat and reduce 

smoke emissions from the flue. 

If your stove or fireplace is equipped with a Condar SteelCat™ catalyst, 

engage the combustor at 400 degrees

. Display and power dot flashes every 3 seconds.

Target catalyst operating zone 700 to 1350 degrees

Efficient and safe fires are between 700 and 1350 degrees. Esthetics and heat desired from your fire 
determine where you want to be.

 Watchman informs you when your catalyst is getting hotter than 

necessary

 and is approaching overheating temperature at 1400 degrees. Many users discover they can 

burn wood longer, still achieving a pretty fire, by adjusting draft to bring temperatures down. The nice 
thing is, when your catalyst is engaged, even an apparent smoky fire is environmentally responsible, 
because the combustor takes care of transforming smoke into extra heat with the only emissions being 
minor water vapor and carbon dioxide. Display flashes every 1 minute; power dot flashes every 3 seconds.

T o   a c t i v a t e   o r   d e a c t i v a t e   t h e  

W a t c h m a n ™

,   p r e s s 

LED display operation guide:

COOL temperature display

At temperatures lower than 250 degrees, Watchman’s visual read-out says 

 and doesn’t display 

precise temperatures in normal 50-degree increments. 

This feature encourages you to accelerate fire 

warm-up quickly for catalytic operation

. Display and power dot flashes every 3 seconds.

Overheating catalyst 1400 degrees and higher

Above 1400 degrees a catalyst no longer achieves any additional catalytic benefit. At 1600 degrees adjust 
draft immediately to avoid destruction of your catalytic combustor and potential damage to stove or 
fireplace components. Display is continuous.

Содержание 9-90

Страница 1: ...st monitor with programmed audio signals Models 9 90 and 9 90AC Fahrenheit temperature display for catalytic wood burning stoves fireplaces Owner s Manual Condar Company 111 Kangaroo Drive Columbus North Carolina 28722 828 436 2102 Condar com Model 9 90 ...

Страница 2: ...tery types Two batteries operate in parallel not in series To install optional second battery push down don t remove the foam Remove insulator cap from second pair of connector wires to install a second battery 3 Where to locate the electronic monitor The 6 foot thermocouple cable allows you to locate Watchman monitor well away from stove or fireplace Don t place on any surface that will exceed 11...

Страница 3: ... of temperature readings is unnecessary and consumes battery power 9 90 Condar s programming of Watchman s LED visual read out limits the temperature display to what s necessary during normal operation In the target operating zone of 700 to 1350 degrees you ll view your current temperature briefly once per minute automatically A single press to the manual DISPLAY TEMP button at any time commands c...

Страница 4: ...nger still achieving a pretty fire by adjusting draft to bring temperatures down The nice thing is when your catalyst is engaged even an apparent smoky fire is environmentally responsible because the combustor takes care of transforming smoke into extra heat with the only emissions being minor water vapor and carbon dioxide Display flashes every 1 minute power dot flashes every 3 seconds To activa...

Страница 5: ...o out After you return your stove or fireplace to target temperature operating zone the AUDIO SIGNAL feature will resume automatically and the dot will illuminate Intermittent beep code can be muted by pressing Audio Signal CATALYST DESTRUCTION and SAFETY At 1600 degrees continuous warning beep code begins This audio warning cannot be manually shut off even by pressing the AUDIO SIGNAL button When...

Страница 6: ...es as to fitness of purpose installation by consumer purchasers or by resellers or consequential damages to other equipment or properties Catalyst Maintenance For helpful tips about maintaining inspecting and replacing a catalytic combustor visit WoodstoveCombustors com Operation_Tips html Catalyst Failure When a catalyst is engaged emissions from a chimney flue should look like white steam Dirty ...

Отзывы: