2.2.2021
Firebox M5800 Hardware Guide
https://www.watchguard.com/help/docs/help-center/en-US/Content/en-US/Hardware-Guides/firebox-m5800-hardware-guide.html
8/18
When you install the device in a rack, make sure that the amount of air flow required for safe
operation of the equipment is not compromised.
Mechanical Loading
When you mount the device in the rack, avoid hazardous conditions caused by uneven mechanical
loading.
Circuit Overloading
Make sure you connect the device to the power supply circuit in such a way that there is no
overloading of the circuits, and no impact on overcurrent protection and supply wiring.
Reliable Grounding
Make sure all rack-mounted equipment is correctly grounded. For example, make sure you use
power strips instead of direct connections to the branch circuit.
Do not use your slide/rail mounted device as a shelf or work space.
Separate the inner rails from the outer rails
Attach the inner rails and front ear brackets to the Firebox
Attach the outer rails to the rack
Install alternate screws on the rails (if needed)
Install the Firebox in the rack
Remove the Firebox from the rack
Interface Module Installation
You can install two additional interface modules in slots A and B of your Firebox. The supported interface
modules are described in detail in the
Interface modules are not hot-swappable. To avoid damage to the system, power
off the Firebox before you install or remove interface modules.
Install an Interface Module
To install an interface module:
1. Disconnect the power cables from the Firebox.
2. Loosen the two captive screws on the slot cover.
3. Remove the slot cover to expose the interface slot.
4. Insert the interface module into the slot, and push it firmly into place.
5. Tighten the two captive screws on the interface module to attach the interface to the Firebox.
6. Reconnect the power cables to the Firebox.
The Firebox starts automatically. When the Firebox starts, Fireware automatically detects all installed interfaces.
Remove an Interface Module