STEP 3. 

WIRELESS SIREN 

 

 

 

 

 

Set the Main  Control Unit 

into  wireless  siren  auto 

test  mode  by  setting  DIP 

switches 1 and 5 to ON. 

Turn  the  external  siren 

keyswitch  to  ON  and  then 

hold  the  siren  in  the 

desired mounting position.  

 

When this mode is entered 

the strobe on the siren will 

flash every 5 seconds, and 

the main unit will beep out 

the signal strength every 5 

seconds.  Note  that  the 

siren  must  be  moved  until 

minimum

  of  3  beeps  is 

heard  from  the  main  unit. 

Reset dipswitches to off. 

 

 

 

 

Mount the siren if wireless 

siren  auto  test  was 

successful. 

 

Drill  mounting  holes, 

(7mm  diameter,  25mm 

minimum  in  depth)  into 

the  chosen  wall.  (If  brick, 

use the green star plugs & 

press  one  into  each  hole. 

Now  make  a  12

 

mm 

diameter hole and push the 

wires through the wall and 

up  into  the  ceiling  for 

power. 

 

Screw  the  top  2  siren 

screws  half  way  in  and 

place  the  unit  onto  the 

wall supporting itself from 

the  top  2  screws,  then 

screw  in  and  tighten  the 

bottom  two  mounting 

screws 

then 

finish 

tightening  the  top  two 

screws.  Run  the  power 

supply  wire  through  the 

roof  to  the  closest  power 

point, 

connect 

power 

supply and switch on.

 

 

 

STEP 4. 

OPERATION 

(Ensure main unit keyswitch is ON)

  

Press 

Button 1             

 

     

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press 

Button 2 

 

 

 

 

     

 

Press 

Buttons 1 & 2 Together 

  

 

 

     

 

 

AWAY mode 

Press  once

  to  arm  the  system  in 

normal 

AWAY  mode. 

The  internal 

screamer  will  beep  at  1-second 

intervals  for  the  30-second  exit  delay 

and  the  outside  siren  will  beep  once. 

The strobe will flash once. 

STAY mode 

Press twice within 3 seconds

 to arm 

the  system  in 

STAY  mode. 

The 

internal  screamer  will  beep  at  2-

second  intervals  for  the  30-second 

exit  delay  and  the  outside  siren  will 

give a low tone beep

 

after the second 

press.

 

Panic mode 

Press  and  hold 

(3  seconds)  to 

activate  PANIC  mode,  the  outside 

siren  will  sound  and  the  strobe  will 

flash  but  the  internal  screamer  will 

not sound. 

 

 

 

DISARMING 

Press once

 to disarm the system. The 

siren will beep twice. The strobe will 

flash for 5 seconds. 

 

 

 

 

 

 

QUIET ARMING and 

DISARMING  

(i.e. No External Siren Beeps) 

For

  quiet  AWAY 

arming  or

DISARMING 

press  both  buttons 

together, once  

For 

quiet  STAY

  arming  press  both 

buttons 

together 

simultaneously, 

twice within 3 seconds. 

STEP 5. 

SYSTEM REGISTRATION & MONITORING SET-UP 

 

Now that the physical installation is complete you will need to create a SecureNet  

Alarm Monitoring Account. 

Please visit www.watchguardalarms.com.au and click on the ‘Create Account’  

button and then follow the instructions.  

If you do not have internet access, please call 1300 653 533 to complete a phone 

registration. Once you have registered your installation is complete. 

IMPORTANT NOTE:

 

When  testing the operation of the system you will NOT 

be  contacted  by  SecureNet  if  the  alarm  is  triggered  but 

then cancelled (disarmed) within 30 seconds. 

 

OFF 