background image

Specifications

 

 

Software:

 

SpecWare 5.0 or greater

 

 
Compatibility:

 Compatible with all WatchDog 

dataloggers (except the WatchDog model 100 button-
type loggers) as well as the Leaf Wetness & 
Temperature Logger and Datalogging Rain Gauges. 
 

Capacity: 

Contains 128K non-volatile memory.  The 

first 96K of memory can be allocated to any 
combination of 8K (WatchDog 100 and 200 series, 
Leaf Wetness & Temperature Logger and Datalogging 
Rain Gauges), 16K (WatchDog 400 series) and 32K 
(WatchDog weather station) dataloggers.  The final 
32K of memory is reserved for one logger or weather 
station of any size.  Therefore, the shuttle can store the 
data from a total of four weather stations, seven 16K 
loggers or thirteen 8K loggers. 
 

Time Accuracy: 

Approximately ± 1minute. 

 

Speed:

 Offloads one full 8K logger in 90 seconds,  one 

full 16K logger in 200 seconds, and one full 32K 
weather station in 400 seconds.. 
 

Battery: 

1 user-replaceable CR-2032 battery.  Battery 

life is about 6 months with normal use. 
 

Interface: 

1-foot logger/shuttle interconnect cable 

Содержание Data Shuttle 3679

Страница 1: ...Data Shuttle PRODUCT MANUAL Item 3679...

Страница 2: ...ustomer support or to place an order call Spectrum Technologies Inc 800 248 8873 or 815 436 4440 between 7 30 am and 5 30 p m CST FAX at 815 436 4460 E Mail at info specmeters com www specmeters com S...

Страница 3: ...are to easily and conveniently retrieve data from your remotely located WatchDog dataloggers The WatchDog shuttle performs the following 3 functions 1 Offloads data from loggers in the field 2 Checks...

Страница 4: ...r From the Launch Options screen click on the Start button From the Launch Options screen you can also check the battery status of the shuttle It is recommended that the battery be changed when the ba...

Страница 5: ...oom for another logger the LCD screen will read FULL No further data can be transferred to the shuttle until it is downloaded and relaunched CAUTION If a logger battery is 25 the LCD screen will read...

Страница 6: ...ll new dataloggers require that you create a new Logger Location the first time the logger is read out The sequence of downloading data from the shuttle to the computer is the reverse of how it was of...

Страница 7: ...on press the green button to scroll to the shuttle position of interest Initiate the download with from the SpecWare Logger menu or with the Read WatchDog Logger button After downloading the shuttle w...

Страница 8: ...cover of the shuttle 2 Remove the back cover 3 Slide the battery out of the battery holder 4 Insert a new CR2032 battery positive side up 5 Replace shuttle cover 6 Tighten back cover screw Confirm tha...

Страница 9: ...Datalogging Rain Gauges 16K WatchDog 400 series and 32K WatchDog weather station dataloggers The final 32K of memory is reserved for one logger or weather station of any size Therefore the shuttle can...

Страница 10: ...a data extraction is necessary In this case con tact Spectrum Technologies for technical assis tance Q When I try to offload a logger in the field the shut tle s LCD reads FAIL A This indicates that...

Страница 11: ...rum will at its op tion either repair or replace products that prove to be de fective This warranty does not cover damage due to im proper installation or use lightning negligence accident or unauthor...

Страница 12: ...12360 S Industrial Dr E Plainfield IL 60585 800 248 8873 or 815 436 4440 Fax 815 436 4460 E Mail info specmeters com www specmeters com...

Отзывы: