WASSELL WW10221N Скачать руководство пользователя страница 1

PART NUMBER WW10221N

6 volt negative earth DC regulator

Important

  -  please  read  these  instructions  carefully  prior  to  fi tting.  This  unit  will  be  damaged  if 

connected with reverse polarity. Before connection please check your chassis earth polarity and make 

sure you have the correct regulator for your earth polarity.

Please note the wiring instructions also require a 15 Amp fuse to be connected in the red wire. The 

regulator will cause this fuse to blow if the battery is connected backwards. If the fuse blows, re-check 

that the wiring and battery polarity are correct. Running the regulator with reverse polarity, even for a 

short duration, will damage it beyond repair. If in doubt contact an expert for advice.

1

 Disconnect the fi eld coil wire marked 1 from F and connect it to the D terminal 

2

 Disconnect fi eld wire marked 2 from earth screw and connect it to F terminal

Old confi guration for 

mechanical regulator

Revised confi guration for

negative earth solid state unit

F

D

FIELD

COIL

1

2

F

D

FIELD

COIL

1

2

1 move this fi eld wire to D terminal

2 move this fi eld wire to F terminal

Field wires must be connected as above drawing