![Waspper WR67160 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/waspper/wr67160/wr67160_operation-manuals_3488835011.webp)
11
10.
Reconnect spark plug wire.
Alternative Procedure
If you cannot perform the Optimum Winterizing Procedure, you can still protect your pressure washer from
winter-damage:
1.
Disconnect all water connections.
2.
Press trigger to bleed any remaining water in the pump.
3.
Remove the gun and hose from the pressure washer. Drain any excess water. Roll hose carefully and do not allow
hose to be kinked.
4.
Store the machine and accessories in a room that does not reach freezing temperature. Do not store near furnace or
other hot areas.
Trouble Shooting Guide
Problem Cause
Correction
Engine will not start
(see Engine Manual
for further engine
troubleshooting)
No Fuel
Low oil
Pressure builds up after two pulls on the
recoil starter or after initial use
Choke level in the “No choke” position
Spark plug wire not attached
Engine on/off switch in Off position
Choke lever in the “choke” position on a
“hot” engine or an engine that has been
exposed to thermal heat for a long period
of time.
Fuel Valve closed
Add Fuel
Add required amount of oil
Squeeze gun trigger to relieve pressure
Move choke to the “choke” position
Attach spark plug wire
Place engine ON/OFF switch in ON
position
Move choke to the “NO CHOKE”
Position
Move fuel Valve lever to the “Open”
Position