The low-pressure inlet on the pump must be fitted with the garden hose adaptor, included in the delivery. 
 
 

  

Commissioning

 

 
 

  Water supply 
 

CAUTION 

Avoid  operating the pump without  a water supply  line connected and fed from the source. The 

water resource yield must correspond with at least 12 litres per minute, at the minimum pressure of 1 bar. If the 
purity of supplied water cannot be guaranteed, the system needs a water filter placed before the pump inlet to 
avoid influx of solid contaminants inside the pump. 
Having connected the hoses, open the water tap fully to its limit position and depress the control lever on the 
high-pressure gun. To deaerate the pump hoses, keep the gun in depressed position until you observe an even 
flow of water out of the quick-coupler. Insert the adaptor quick-coupler with the high-pressure nozzle. 

If the 

pump  has  not  developed  pressure  within  30  seconds  following  its  commissioning, 
switch  the  engine  off  and  proceed  in  compliance  with  instructions  defined  in  the 
Troubleshooting  section!  Any  dry  cycling  of  the  pump  for  a  period  exceeding  30 
seconds may result in damage! 

Any material damage caused due to inobservance of this instruction renders the warranty void. 

 

  CAUTION WHEN USING SELF-PRIMING FUNCTION 
 

For  pumps  provided  with  the 

SELF-PRIMING

  function:

  The  high-pressure  washer  and  the  filling  hose  from 

Waspper s.r.o. (special accessories, catalogue number SP000-HI001) can be used for removal of surface water, 
e.g.  from  storm  water  reservoirs.  The  water  in  reservoir  must  be  clean,  free  of  any  contaminants  or  sludge. 
Contaminated water causes irreversible damage to internal components of the high-pressure pump

Fill the filling hose with water up to the rim to eliminate any air bubbles inside.  
Connect the hose to the filler neck directly (without the quick-coupler adaptor, included in the delivery). Make 
sure the sealing between the hose and the pump neck is free of any damage. 
Submerge the other end into the water reservoir. Remove the nozzle from the quick-coupler on the end of high-
pressure gun adaptor. Start the engine and depress the gun control lever to let the water flow out freely, until 
the stream comes out free of any air bubbles. Once the system has been bled, fit the nozzle and restart the 
engine again. The pump is ready for operation now. If the pump has not developed pressure with the engine 
running  for  30  seconds,  switch  the  engine  off  and  proceed  in  accordance  with  instructions  defined  in  the 
Troubleshooting section. 

CAUTION  If the pump draws air in, the whole deaerating procedure must be repeated. 
 
 

Содержание W3000HG

Страница 1: ...Operation Manual EN W3000HG Engine driven Translation of the original operation manual The picture serves for reference only and it may not represent an exact match of the device delivered...

Страница 2: ...environment where the device will not be exposed to direct splashing of contaminated water with solid particles Environmental protection The packaging materials are recyclable Packaging disposal meth...

Страница 3: ...er developed during internal circulation of water inside the pump during operation without discharge of the high pressure water Once the safety valve opens automatically some of the hot water pours ou...

Страница 4: ...uction renders the warranty void CAUTION WHEN USING SELF PRIMING FUNCTION For pumps provided with the SELF PRIMING function The high pressure washer and the filling hose from Waspper s r o special acc...

Страница 5: ...a unsealed openings When working with the engine on turn the device in such direction where the exhaust does not remain pointed at persons standing in the vicinity or any opening in nearby structures...

Страница 6: ...ery 50 hours or at the end of the season Clean the air filter Engine oil change Every 100 hours Inspection and adjustment of the ignition spark plug electrode Fuel pipeline check There may be rare cas...

Страница 7: ...t one of the authorised collection points Engine oil is hazardous waste Fill the engine with the correct amount and type of engine oil For engine oil specifications see below For specific filling volu...

Страница 8: ...or appearance of the particular object Setting the jet further from the surface of object being washed will reduce the pressure generated by water impact and alleviate the aggressive washing effect On...

Страница 9: ...age to internal components if not drained properly Excess water draining procedure Make sure the engine switch p 4 pos C is in the OFF position Disconnect the supply hoses from the pump Grasp the star...

Страница 10: ...ntre Insufficient engine performance 1 Clogged air filter 2 Old fuel 1 Clean the air filter 2 Fill the tank with a fresh fuel Use original parts only That will ensure smooth operation of your device W...

Страница 11: ...P zariadenia Serial number ES inspection report Noise level measured Lwa Guaranteed noise level W3000HG xx0001001 xx9999999 97dB 99 dB Protokol o sk ke zo d a Certificate issued by Technick in pekcia...

Страница 12: ...the customer is obliged to mail the damaged device to the manufacturer s address The device must be complete including accessories and packed properly to prevent its damage during transport it must be...