Waspper W3000HC Скачать руководство пользователя страница 4

 

 

     

     

Nut 

 
                                      

Nozzle

   

Quick-coupler 

  

  

    

 
The low-pressure inlet on the pump must be fitted with the garden hose adaptor, included in the delivery. 
 
 

  

Commissioning

 

 
 

  Water supply 
 

CAUTION 

Avoid  operating  the  pump  without  a  water  supply  line  connected  and fed from  the  source.  The 

water resource yield must correspond with at least 12 litres per hour, at the minimum pressure of 1 bar. If the 
purity of supplied water cannot be guaranteed, the system needs a water filter placed before the pump inlet to 
avoid influx of solid contaminants inside the pump. 
Having connected the hoses, open the water tap fully to its limit position and depress the control lever on the 
high-pressure  gun.  To  deaerate  the  pump  hoses,  keep  the  gun  in  depressed  position  until  you  observe  an 
even flow of water out of the quick-coupler. Insert the adaptor quick-coupler with the high-pressure nozzle. 

If 

the  pump  has  not  developed  pressure  within  30  seconds  following  its 
commissioning,  switch  the  engine  off  and  proceed  in  compliance  with  instructions 
defined  in  the  Troubleshooting  section!  Any  dry  cycling  of  the  pump  for  a  period 
exceeding 30 seconds may result in damage! 

Any material damage caused due to inobservance of this instruction renders the warranty void. 

 

  CAUTION WHEN USING SELF-PRIMING FUNCTION 
 

For  pumps  provided  with  the 

SELF-PRIMING

  function:

  The  high-pressure  washer  and  the  filling  hose  from 

WPW  Center  (special  accessories,  catalogue  number  SP000-HI001)  can  be  used  for  removal  of  surface 
water,  e.g.  from  storm  water  reservoirs.  The  water  in  reservoir  must  be  clean,  free  of  any  contaminants  or 
sludge. Contaminated water causes irreversible damage to internal components of the high-pressure pump

Fill the filling hose with water up to the rim to eliminate any air bubbles inside.  
Connect the hose to the filler neck directly (without the quick-coupler adaptor, included in the delivery). Make 
sure the sealing between the hose and the pump neck is free of any damage. 
Submerge  the  other  end  into  the  water  reservoir.  Remove  the  nozzle  from  the  quick-coupler  on  the  end  of 
high-pressure gun adaptor. Start the engine and depress the gun control lever to let the water flow out freely, 
until the stream comes out free of any air bubbles. Once the system has been bled, fit the nozzle and restart 
the  engine  again.  The  pump  is  ready  for  operation  now.  If  the  pump  has  not  developed  pressure  with  the 
engine  running for  30  seconds,  switch  the  engine  off and  proceed  in  accordance  with instructions  defined  in 
the Troubleshooting section. 

CAUTION  If the pump draws air in, the whole deaerating procedure must be repeated. 
 
 

Содержание W3000HC

Страница 1: ...Operation Manual EN W3000HC Engine driven Translation of the original operation manual The picture serves for reference only and it may not represent an exact match of the device delivered...

Страница 2: ...an environment where the device will not be exposed to direct splashing of contaminated water with solid particles Environmental protection The packaging materials are recyclable Packaging disposal me...

Страница 3: ...out discharge of the high pressure water Once the safety valve opens automatically some of the hot water pours out of the pump to be replaced with cold water from the connected supply However this saf...

Страница 4: ...ruction renders the warranty void CAUTION WHEN USING SELF PRIMING FUNCTION For pumps provided with the SELF PRIMING function The high pressure washer and the filling hose from WPW Center special acces...

Страница 5: ...unsealed openings When working with the engine on turn the device in such direction where the exhaust does not remain pointed at persons standing in the vicinity or any opening in nearby structures ga...

Страница 6: ...ry 100 hours Inspection and adjustment of the ignition spark plug electrode Fuel pipeline check There may be rare cases when the protective metal guards come loose during operation These parts need to...

Страница 7: ...ng volumes refer to the Technical data section Set the pump on a horizontal surface Fill the engine with approximately of the oil amount required Screw the plug back into the oil sump With the engine...

Страница 8: ...duce the pressure generated by water impact and alleviate the aggressive washing effect On the other hand proximity of the jet to the surface will increase the washing performance of water on the part...

Страница 9: ...age to internal components if not drained properly Excess water draining procedure Make sure the engine switch p 4 pos C is in the OFF position Disconnect the supply hoses from the pump Grasp the star...

Страница 10: ...centre Insufficient engine performance 1 Clogged air filter 2 Old fuel 1 Clean the air filter 2 Fill the tank with a fresh fuel Use original parts only That will ensure smooth operation of your devic...

Страница 11: ...frame section grip Pressure hose High pressure nozzle Hose bracket High pressure gun Tank Air filter Gun adaptor with quick coupler Exhaust Engine Engine bracket Bottom section of frame with chassis...

Страница 12: ...t details High pressure washer TYPE Inspection reports Noise level measured Guaranteed noise level W3000HC 2617 3 2017 01 97 dB 99 dB Certificate issued by Technick in pekcia a s Trnavsk cesta 56 8210...

Страница 13: ...e the customer is obliged to mail the damaged device to the manufacturer s address The device must be complete including accessories and packed properly to prevent its damage during transport it must...

Отзывы: