background image

1

 -

1. Take any metals into contact with the terminals in connectors.
2. Use the scanner where any inflammable gases.

If following condition occur, immediately power off the host computer, 

disconnect the interface cable, and contact your nearest dealer.
1. Smoke, abnormal odors or noises come from the scanner.
2. Drop the scanner so as to affect the operation or damage its housing.

Do Not

Do not do behavior below.
1. Put the scanner in places excessively high temperatures such as expose 

under direct sunlight.

2. Use the scanner in extremely humid area or drastic temperature 

changes.

3. Place the scanner in oily smoke or steam environment such as cooking 

range.

4. Be covered or wrapped up the scanner in bad-ventilated area such as 

under cloth or blanket.

5. Insert or drop foreign materials or water into scanning window or vents.
6. Using the scanner while hand is wet or damp.
7. Use the scanner with anti-slip gloves containing plasticizer and 

chemicals or organic solvents such as benzene, thinner, insecticide etc 

to clean the housing. Otherwise, it could not result fire and electrical 

shock but housing may be broken and injured.

8. Scratch or modify the scanner and bend, twist, pull or heat its interface 

cable.

9. Put heavy objects on interface cable.
Do not stare the light source from the scanning window or do not point the 

scanning window at other people’s eyes or eyesight may be damaged 

by direct exposure under the light.

Do not put the scanner on an unstable or inclined plane.
The scanner may drop, creating injuries.

Once the interface cable is damaged such as exposed or broken copper 

wires, stop using immediately and contact your dealer. Otherwise, it could 

result fire or electrical shock.

WARNING AND CAUTION

2

 -

FCC WARNING STATEMENT

This equipment has been tested and found to comply with the limits for a Class B digital 

device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions, may cause harmful interference 

to radio communications. However, there is no guarantee that interference will not 

occur in a particular installation. If this equipment does cause harmful interference to 

radio or television reception, which can be determined by turning the equipment off 

and on, the user is encouraged to try to correct the interference by one of the following 

measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an 
uncontrolled environment. End users must follow the specific operating instructions for 
satisfying RF exposure compliance. To maintain compliance with FCC exposure 
compliance requirement, please follow operation instruction as documented in this 
manual. Any changes or modifications not expressly approved by the party 
responsible for compliance could void the user's authority to operate the equipment.

 

This device complies with Part 15 of the FCC Rules. Operation is subject to the 
following two conditions: 
(1) This device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undesired operation.
This device and its antenna(s) must not be co-located or operating in conjunction with 
any other antenna or transmitter.

Radiation Exposure Statement:  

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled 

environment. End users must follow the specific operating instructions for satisfying RF 

exposure compliance. To maintain compliance with FCC exposure compliance requirement, 

please follow operation instruction as documented in this manual. 

LASER DEVICES

Complies with 21CFR1040.10 and 1040.11 except for deviations pursuant to Laser 

Notice No. 50, dated June 24, 2007.

EN60825-1: 2007

IEC60825-1 (Ed. 2.0)

Содержание WWS550SBR

Страница 1: ...Wireless Handheld Barcode Scanner Quick Guide RevX P N 8012 006600X WWS550SBR BARCODE SCANNER Quick Guide For full user s manual please contact your local distributor ...

Страница 2: ...tion This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by tur...

Страница 3: ...r Power off Disconnected or Discoverable Good Read Low power Charging Single beep Good read Single short beep The scanner reads a Code39 of ASCII in configuration procedure Two beeps i Wireless connection ii The scanner successfully reads a configuration barcode Four beeps Hi Lo Hi Lo Out of range Poor connection Five beeps Low power Three beeps Wireless disconnection Three short beeps i The scann...

Страница 4: ...r We also suggest to release the strap from your finger for 1 minute after 2 hours of continuous use if your finger feels uncomfortable Scan one of below configuration barcodes to determine your interface STEP 3 INTERFACE SELECTION Recommended C006 C006 USB VCP C008 C008 USB HID BT HID E043 E043 Memory Mode C035 c035 1 BT HID Emulates a Bluetooth HID keyboard that transmits barcode data to the hos...

Страница 5: ...XXX on the discovered device list of your Bluetooth XXXXXX are the last 6 digits of MAC address which can also be found on the product label 5 The scanner will emit two beeps to verify the connection iOS Android To toggle iOS touch keyboard please simply press trigger button twice 1 Enter Settings 2 Enter Language input 3 In Keyboard input window tap Default to continue 4 Turn off Hardware Physica...

Страница 6: ...The default timeout is 00 minute and 30 seconds For example to set the timeout as 5 minutes 30 seconds 1 Scan Set Minute 2 Scan 0 5 on page 14 Range 00 60 Range 00 60 3 Scan Set Minute 4 Scan Set Second 5 Scan 3 0 on page 14 6 Scan Set Second The period of inactivity before auto power off 9 10 POWER OFF TIMEOUT BT HID Warning This will cause the battery to drain quickly ...

Страница 7: ...ENCE BEEPER P023 A007 F012 ABORT CHECK VERSION BEEP OFF F018 A001 DEFAULT BEEP ON LASER ALWAYS ON LED AUTO ADAPTIVE LASER ALWAYS ON LED ON AFTER 1 SEC F059 F059 F049 F049 LASER ALWAYS ON LED ALWAYS ON F048 F048 LASER OFF LED ALWAYS ON F046 F046 ...

Страница 8: ...KEYBOARD LAYOUT C010 ENGLISH USA C018 ENGLISH UK C011 GERMAN C012 FRENCH C013 SPANISH C014 ITALIAN C009 JAPAN 106 key CANADIAN TRADITIONAL C034 NORWEGIAN C029 SWEDISH C026 PORTUGUESE C031 CANADIAN FRENCH C025 ...

Страница 9: ... 101 KEY BRAZILIAN PORTUGUESE SLOVAK SWISS FRENCH DUTCH DANISH BELGIAN AZERTY C016 SWISS GERMAN KEYBOARD LAYOUT C017 CZECH QWERTY C022 CZECH QWERTZ HUNGARIAN QWERTZ C021 C015 ALT CODE C024 C023 C033 C032 C027 C028 C030 ...

Страница 10: ...SYMBOLOGIES ENABLE ALL CODE A002 K010 CODE 32 L010 N001 M010 L001 UK PLESSEY MSI INDUSTRIAL 2 OF 5 MATRIX 2 OF 5 CODE 93 L014 G010 N017 N032 N010 N026 IATA TELEPEN GS1 DATABAR GS1 DATABAR LIMITED GS1 DATABAR EXPANDED ...

Страница 11: ...rieve stored data please connect the scanner to the host with cable access removable storage device MiniScan from which you may open or copy the file BARCODE txt to your computer To delete ONE stored data please scan below barcode Alternatively you may press the function button once R005 R005 C035 c035 MEMORY MODE DELETE LAST DATA To delete ALL stored data simply delete the file BARCODE txt in the...

Страница 12: ...arator 2 Scan from the full ASCII table 3 Scan Field Separator R010 R010 FIELD SEPARATOR DELIMITER R011 R011 DATA FORMAT 2 4 Date Barcode Data Code Item Code Item 3 Time Example To set Date to 2017 08 01 Year Month Day 1 Scan Set Date 2 Scan 1 7 0 8 0 1 on page 14 3 Scan Set Date Example To set Time to 08 10 30 am Hr Min Sec 1 Scan Set Time 2 Scan 0 8 1 0 3 0 on page 14 3 Scan Set Time R006 R006 S...

Страница 13: ...YYYY DD MM YY MM DD YY YYYY MM DD YY MM DD DD MM MM DD Code Format Code Format 09 10 11 12 13 14 15 16 DD MM YYYY MM DD YYYY DD MM YY MM DD YY YYYY MM DD YY MM DD DD MM MM DD The default Time Format is HH MM SS Code 01 below are available formats and their setup codes Example To set Time Format to HH MM Code 02 1 Scan Time Format 2 Scan 0 2 on page 14 3 Scan Time Format R009 R009 TIME FORMAT 01 HH...

Страница 14: ... 25 26 TEST BARCODES EAN Code 128 12345678 Code 39 CODE 39 TEST Interleaved 2 of 5 9876543210 716415 4 942052 ...