background image

Wasp Applications

82

WDT92

Command

Description

Application Title

Type the name of the application in the way it should 
appear on screen for the end-user.

Executable

Displays the path for the executable file you want to run.

Browse

Tap 

 to browse for the desired executable file. You can 

associate an executable program with the specified button. 
The results of this search are displayed in the 

Executable

 

textbox.

Arguments

Type any command line arguments to be used when an 
application is executed.

Icon File

Displays the path to the desired icon file.

Browse

Tap 

 to browse for the desired icon file. The results of 

this search are displayed in the 

Icon

 

file

 textbox.

Run Application at 
Startup

Select to force the application to auto start when the 
Application Selector starts up. Applications will be started 
in the order listed in the authorized application list.

Delay

Enter a delay duration in seconds in the combo box.
This option delays auto start of application(s) to allow 
drivers to load before starting applications.

OK

Tap to add/save changes.

X

Tap to cancel.

Содержание WDT92

Страница 1: ...WDT92 Rugged Mobile Computer with 1D 2D Imager User s Manual...

Страница 2: ...an acquire printed versions by contacting your Wasp representative Electronic versions may either be downloadable from the Wasp Barcode Technologies website www waspbarcode com or provided on appropri...

Страница 3: ...th USB 8 Charge with the Single Slot Dock 9 Replace the Battery 11 SD Card 17 Install the MicroSD Card 17 Getting Started 19 Power On 19 Desktop Window 20 Taskbar 20 Using the Stylus Pen 21 WEC7 Touch...

Страница 4: ...Audio 53 Volume Sounds 54 Bluetooth Manager Device Setup 55 Enable Bluetooth 55 Connect to Other Bluetooth Devices 57 Configure or Unpair Bluetooth Devices 61 Persistent Registry 62 Wasp Applications...

Страница 5: ...erequisites 101 Data Capture 103 Imager 1D Data Capture 103 Imager 2D Data Capture 106 Connections 109 Windows Mobile Device Center 109 USB Connection 111 USB Direct Connection 111 USB HandyLink Conne...

Страница 6: ...d Regulatory Information 142 General Safety Rules 142 Power Supply 143 Laser Safety 144 LED Class 156 FCC IC Labeling 157 FCC Compliance 157 ISED Compliance 159 Radiofrequency Radiation Exposure Infor...

Страница 7: ...is manual uses the following conventions Mobile computer and WDT92 refer to WDT92 mobile computer Single Dock refers to the WDT92 Single Slot Dock The label artworks may be only a draft Refer to the p...

Страница 8: ...res in hyper stores and supermarkets convenience stores grocery or DIY Wasp s WDT92 mobile computer fits most any retail in store requirement for mobile data collection or validation And with the opti...

Страница 9: ...nd strap Lanyard for pistol grip models only Quick Start Guide Safety Regulatory Addendum End User License Agreement EULA Sheet Remove all the components from their packaging check their integrity and...

Страница 10: ...View Back View ON OFF Power Key LEDs Receiver Speaker Color Display Front Scan Key Keyboard Laser Safety Label Micro USB Connector Loudspeaker Trigger Button for use with the optional pistol trigger P...

Страница 11: ...Introduction User s Manual 5 B Top View Bottom View Data Capture Window HandyLink connector host device...

Страница 12: ...Introduction 6 WDT92 NOTES...

Страница 13: ...User s Manual 7 Battery Install the Battery To install the battery pack insert the battery s alignment lugs into the recesses then press firmly until the battery latch clicks twice...

Страница 14: ...the charging process has been completed the charging LED glows green constantly The charging LED flashes red when a charging error is detected Charge with USB You can use a standard micro USB to USB...

Страница 15: ...e an additional battery pack by inserting it into the rear slot of the dock NOTE The WDT92 may get warm during charging this is normal and does not mean a malfunction CAUTION By default the battery pa...

Страница 16: ...onomy varies according to many factors such as the frequency of barcode scanning RF usage battery life storage environmental conditions etc Close to the limits of the working temperature some battery...

Страница 17: ...ace the Battery To replace the battery pack follow the steps below 1 Turn off the WDT92 press the power key and wait for device power off 2 Press the latch release button and pull the battery latch do...

Страница 18: ...orities WARNING Use only Wasp approved batteries and accessories for battery charging Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructi...

Страница 19: ...induction cook surfaces or similar devices Doing so may cause the battery pack to generate heat explode or ignite Using the battery pack in this manner may also result in a loss of performance and a s...

Страница 20: ...nails strike it with a hammer step on it or otherwise subject it to strong impacts pressures or shocks Do not disassemble or modify i e bend crush or deform the battery pack The battery pack contains...

Страница 21: ...ack when the device is turned on Do not remove or damage the battery pack s label Do not use the battery pack if it is damaged in any part Battery pack usage by children should be supervised Collect a...

Страница 22: ...Battery 16 WDT92 NOTES...

Страница 23: ...ert the card follow the steps below 1 Turn off the WDT92 2 Remove the battery pack see Replace the Battery on page 11 steps 1 to 3 3 Shift the cardholder upwards and then pull it up 4 Insert the micro...

Страница 24: ...avoid damaging the microprocessors in the WDT92 or the microSD card itself Proper ESD precautions include but are not limited to working on an ESD mat and ensuring that the operator is properly ground...

Страница 25: ...screen Wait a few seconds before starting any activity so that the mobile computer completes its startup procedure The mobile computer goes into power off low power with display and keyboard backligh...

Страница 26: ...on the Windows Embedded Compact 7 desktop appears on the screen Wait a few seconds before starting any activity so that the mobile computer completes its startup procedure Windows Embedded Compact 7...

Страница 27: ...cons display the system battery status Bluetooth Manager icon displays whether Bluetooth is enabled paired or turned off Double tap this icon to open the Bluetooth Manager control panel applet Network...

Страница 28: ...s below 1 Tap Start Settings Control Panel Double tap the Stylus icon to open the Stylus Properties window CAUTION Use only original Wasp styluses supplied with the product itself In harsh application...

Страница 29: ...Getting Started User s Manual 23...

Страница 30: ...e 2 Carefully press and briefly hold the stylus on the center of the target Repeat as the target moves around the screen 3 By completing the calibration procedure you implicitly accept the new calibra...

Страница 31: ...Getting Started User s Manual 25 Keyboards Alphanumeric Keypad 38 Keys...

Страница 32: ...among folder files Yellow modifier toggle key when pressed before a standard key it enables the character or function printed in yellow above the key Blue modifier one shot key when pressed before a...

Страница 33: ...al 27 After a Blue modifier key press the Backlight key turns the backlight on and off After a Blue modifier key press the blue arrows allow moving forwards or backwards within the Internet Explorer b...

Страница 34: ...served The Registry is restored from persistent memory A clean boot restores the WDT92 to a clean configuration both the Registry and the file system returns to a clean status that conforms to factory...

Страница 35: ...down the Esc 0 keys simultaneously promptly after resetting A dialog box will appear asking for confirmation Press the Enter Key Warm Boot Cold Boot Clean Boot Registry Restored from flash Restored fr...

Страница 36: ...amber when the device raises a notification to the user Keyboard LED center Off Keyboard in primary Yellow Constant Yellow alternate key mode Blue Constant Blue alternate key mode Pink CapsLock enabl...

Страница 37: ...User s Manual 31 Settings Control Panel From the Start menu tap Settings Control Panel Below is an expanded view of the Control Panel showing all of the applets...

Страница 38: ...e tap the Decoding icon Tap Configure and select General 1D barcode or 2D barcode then use the menu or tap the left and right arrow keys to navigate the different pages of the Decoding Properties wind...

Страница 39: ...n spot beep or vibration the scanner emits on a good read You can also set the volume and tone of the beeps Good Read Use it to enable disable good read notifications LED Green Spot LED Drag the Timeo...

Страница 40: ...tting Allows to format the barcode text by enabling and configuring the use of prefix suffix and data separator Scroll the Add special drop down list to select a special character to be added in the c...

Страница 41: ...t the beginning of the decoded barcode DL ID is a Wasp specific character identifier User ID is a user specific character identifier you can set in the related symbology settings menu Group Separator...

Страница 42: ...WDT92 Decoding Options Use it to configure the User ID for symbologies Redundancy and Aggressive Decoding if supported by the decoding module Select a symbology to view or change the available propert...

Страница 43: ...splay It improves capability to read barcodes from LCD screen e g displayed on smartphone display Enable picklist If selected it allows you to pick and decode a barcode from multiple barcodes printed...

Страница 44: ...rogrammable time upon pressing the scan button Drag the Timeout slider to set the maximum amount of time the scanner attempt to decode after target timeout Release Scan Scanning takes place after the...

Страница 45: ...vice goes on scanning until the number of Labels for good read is reached Select Enable indicators for each label to get an intermediate notification for each label decoded Keyboard Wedge Use it to en...

Страница 46: ...Settings Each barcode symbology can be customized with additional settings that may affect that specific barcode decoding Tap Configure and use the 1D barcode 2D barcode drop down menus to configure...

Страница 47: ...barcode symbology Tap the left and right arrow keys to navigate the different pages of the barcode symbology pages Decoding Settings Tap Settings to change symbologies settings or to restore previous...

Страница 48: ...Settings 42 WDT92 settings to a persistent storage you need to save the Registry using the Persistent Registry applet in the Control Panel...

Страница 49: ...mode application that provides an interface for configuring and operating an installed wireless network interface card wireless adapter Tap Start Programs WLink WCU to open the WCU screen Create a New...

Страница 50: ...ws any device to authenticate and then attempt to communicate with the access point Using open authentication any wireless device can authenticate with the access point but the device can communicate...

Страница 51: ...ccess point The device that is requesting authentication encrypts the challenge text and sends it back to the access point If the challenge text is encrypted correctly the access point allows the requ...

Страница 52: ...P key to the access point which uses the key for all unicast data signals that the server sends to or receives from the client The access point also encrypts its broadcast WEP key which is entered in...

Страница 53: ...Settings User s Manual 47 4 Tap the User Credentials tab to enter the EAP methods user credentials 5 Tap the Authentication tab to select the EAP inner method...

Страница 54: ...to complete The new profile now appears in the WCU profile list Each EAP profile can be either Pairwise Master Key Caching PMK or Opportunistic Key Caching OKC By default OKC radio button is enabled...

Страница 55: ...s User s Manual 49 Edit a Profile Select a profile in WCU profile list and tap Edit on the navigation menu bar Delete a Profile Select a profile in WCU profile list and tap Delete on the navigation me...

Страница 56: ...list and tap Connect on the navigation menu bar Tap the Status tab to display the connection status Disconnect from a Profile Select a connected profile in WCU profile list and tap Disconnect on the n...

Страница 57: ...t a network from the list Depending on whether or not the adapter network is connected to that network the Connect or Disconnect button on the menu bar will be enabled 2 Tap Connect or Disconnect 3 WC...

Страница 58: ...Settings 52 WDT92 Refresh Tap Refresh to manually refresh the scan list Each click on this button triggers a scan request to driver...

Страница 59: ...ties window allows to set the volume for the speaker and the microphone From the control panel main window double tap the Audio icon The audio control panel can be used to independently set the playba...

Страница 60: ...Settings 54 WDT92 Volume Sounds From the control panel main window double tap the Volume Sounds icon The Volume Sounds applet configures audio features of all speakers and headphones...

Страница 61: ...luetooth To turn the Bluetooth on 1 Double tap the Bluetooth Manager icon from the Control Panel window 2 Tap Settings The Settings tab allows you to enable or disable the Bluetooth radio and specify...

Страница 62: ...al COM port to use for the connection 4 Tap Find Me if you want to make the WDT92 discoverable to other Bluetooth devices for 60 seconds allowing them to set up a connection Tap OK on the Find Me pop...

Страница 63: ...the type of device you want Printer Serial or All or tap Discovery Discover to skip this step The WDT92 will search for Bluetooth devices within range NOTE If you attempt to set up a connection when t...

Страница 64: ...Settings 58 WDT92 Icon Service Dialup Networking Printer Object Push OPP Object Exchange OBEX ActiveSync Human Interface Device HID Keyboard Serial Personal Area Network PAN Modem Headset Handsfree...

Страница 65: ...n and then tap Connect 4 Select a service and configure any encryption authentication or virtual port options required by the service selected Virtual Port allows you to specify the incoming port whic...

Страница 66: ...dialog box will request that you enter a PIN Use the Input Panel or the keyboard to type the PIN Tap OK to complete The dialog box will also appear when an authentication request is received from anot...

Страница 67: ...he Connections tab Use the Virtual Port drop down menu to change the Virtual Port Tap Sync to initiate a Sync available only if the service is an ActiveSync connection Tap Delete to remove the device...

Страница 68: ...pplications and hardware devices The Registry also contains information that the operating system continually references to during operation To persist the Registry settings between boots follow the s...

Страница 69: ...iming 1 From the Persistent Registry window select a time interval from the menu 2 Tap OK to save and exit To cancel the Persistent Registry timing 1 From the Persistent Registry window deselect the P...

Страница 70: ...Settings 64 WDT92 NOTES...

Страница 71: ...cations Use the Select a button drop down menu to select the button you want to assign a function to and then select an application from the Assign a function drop down menu Command Description Select...

Страница 72: ...a function This drop down list shows the available functions Application Displays the path to the selected application Browse Tap to browse for application files You can associate an executable progr...

Страница 73: ...NOTE Make sure you do not attempt to add a button that is already defined CAUTION The keyboard wedge can activate assigned buttons using alphanumeric characters Barcodes containing characters associa...

Страница 74: ...plications The application switcher is activated via an assigned shortcut key specified in the Quick Buttons tab see Persistent Registry on page 62 When the assigned button is pressed the dialog box b...

Страница 75: ...S settings Use the Application Selector to replace the desktop with a selection of authorized applications Restrict user access in Internet Explorer Set up configuration and customized error recovery...

Страница 76: ...Desktop Select to activate the WDU functions such as Windows Access Restrictions and Application Selector Enter password Allows to specify a password when this utility is launched Re enter password Re...

Страница 77: ...d can consist of all standard keyboard characters 2 Re enter the password in the second text box 3 Tap Set Password to enable the password 4 Tap OK to close the Password Set dialog box NOTE Be sure to...

Страница 78: ...x 3 Tap Set Password Remove a Password To remove a password 1 Enter blank in both password fields 2 Tap Set Password Password Request Dialog Box Once the password is set the next time you launch the W...

Страница 79: ...ou to input the correct one 2 Tap OK to verify the password or tap X to cancel Locked Web Browser Options LockedWeb Tab Tap the LockedWeb tab to access the Locked Web Browser configuration For further...

Страница 80: ...ays available Error Types 400 Invalid Syntax 403 Request Forbidden 404 Object Not Found 406 No Response Format 410 Page Doesn t Exist 500 Internal Server Error 501 Server Can t Do That Generic Error N...

Страница 81: ...Web Browser command keys will work e g Ctrl O to exit When not selected all keys will be processed normally by the system and the browser Quick Buttons keys will work normally all Locked Web Browser c...

Страница 82: ...er from loading the local intranet page from cache instead of navigating to the Network Disconnected error redirection page Allowed Website List Restricts browsing only to files and URLs in the Allowe...

Страница 83: ...Browser context menu Selecting the item pops up a dialog displaying the URL for the current web page About Adds an About item to the Locked Web Browser context menu Selecting the item pops up the Abo...

Страница 84: ...ay the status of Wi Fi radio and battery Proxy Settings Use Proxy Enable proxy server to act as connection portal for access to a remote server Address IP address of proxy server Port Port of proxy se...

Страница 85: ...pplications in full screen mode and prevents users from accidental or unauthorized use of the taskbar Internet Explorer and any other resident applications Status Icons Options Icon size Sets the stat...

Страница 86: ...Start menu enabled Select to display the Start Menu This option is only available when Taskbar enabled is selected AutoSIP enabled Enables the AutoSIP Windows feature Scroll bars enabled Select to dis...

Страница 87: ...tion Selector Options Enable Application Selector Select to enable the application selector Show status icons Select to enable the status icons view see Status Icons Options Status Tab on page 78 The...

Страница 88: ...ommand line arguments to be used when an application is executed Icon File Displays the path to the desired icon file Browse Tap to browse for the desired icon file The results of this search are disp...

Страница 89: ...ist of applications By default the Application Selector comes with no applications preset The administrator can customize this list as shown in AppSelector Options AppSelect Tab on page 80 Additionall...

Страница 90: ...rd is required to exit This means users can only access web applications and websites set by the administrator In full screen mode status icons may be used to display signal strength and battery statu...

Страница 91: ...a home page C optional parameter which disables the ctrl keys including the one to exit Locked Web Browser Special Metatags General Metatag Comments A metatag is a special HTML tag that stores informa...

Страница 92: ...settings stay in effect until they are changed by another metatag Trigger Metatag DL_Triggers Enable or Disable all triggers If the page contains this tag the triggers are enable or disable depending...

Страница 93: ...upon page load Example meta http equiv DL_Reboot content OnPageLoad Exit Metatag DL_Exit Exit the Locked Web Browser Content OnPageLoad Exit immediately upon page load If Exit password has been enable...

Страница 94: ...Code_M25 DL_Code_CODABAR DL_Code_93 DL_Code_UPCA DL_Code_UPCE DL_Code_EAN13 DL_Code_EAN8 DL_Code_MSI DL_Code_MSR DL_Code_GS1_14 DL_Code_GS1_LIMIT DL_Code_GS1_EXP DL_Code_PDF417 DL_Code_DATAMATIX DL_Co...

Страница 95: ...on the page For instance when entering data in a text box a character assigned as a DL_Key would not be entered in the text box Instead the javascript action would occur Refer to the Microsoft websit...

Страница 96: ...and start listening for scan events A scanned barcode tag result will be used as an argument to that javascript function which is then invoked If the content value is Wedge then the device will stop l...

Страница 97: ...s ready to use for data entry needs Pal Communicator is a PC application that allows you to manage the data transfer between a host computer and mobile devices For further information refer to the Pal...

Страница 98: ...the specified command line arguments It will take into account any AutoStart options at the beginning of the line Upon a Cold Boot AutoStart installs all the CAB files located in the FlashDisk CAB fo...

Страница 99: ...ractive installers you should either install the CABs manually or review the section Interactive CAB Install on page 94 CAUTION In certain environments CAB files will be deleted after execution To pre...

Страница 100: ...enamed File_ cab to force AutoStart to not install the CAB in silent mode This specially named CAB file should be placed in the AutoStart folder with other CAB files intended for installation on the n...

Страница 101: ...ine arguments Autostart option s full path to executable command line arguments Sample windows pword exe file doc The following table breaks down the sample Autostart ini line Spaces must be placed be...

Страница 102: ...me quotes are required to distinguish what the actual executable name is The following is an example of this Program Files ScannerApp exe run valid Program Files ScannerApp exe run invalid The second...

Страница 103: ...ed as the first character of the line If the comment option is specified in the options elsewhere it is ignored Do not wait on line completion This will cause the line to execute and immediately move...

Страница 104: ...g on the current line to complete execution Query Option The query option is intended for use when debugging the autostart ini When a line with this option is executed the fol lowing dialog box will a...

Страница 105: ...bes the results of each choice NOTE The fields may be broken up into multiple lines as shown in the example due to limited space in the dialog box Button Action Yes The current line will execute No Th...

Страница 106: ...xecute Program with the argument Files App exe Program Files App exe run invalid This will execute Program with the argument Files App exe run Program Files App exe run This will execute the program P...

Страница 107: ...vice Center 6 1 or newer for Windows 7 64 bit computers http www microsoft com download en details aspx id 31 82 For C C C development Microsoft Visual Studio 2008 Microsoft Visual Studio 2008 Service...

Страница 108: ...lopment Kits Refresh is required for all Windows Mobile or Windows Embedded Handheld 6 5 devices using C C C languages Go to this link to download the file http www microsoft com en us download detail...

Страница 109: ...settings Imager 1D Data Capture The imager uses digital camera technology to take a digital picture of a barcode the image is stored in memory and software decoding algorithms are executed to extract...

Страница 110: ...he scan window at the barcode from a distance within the reading range 3 Press the scan key or the pistol trigger The green lighted band emitted by the imager must completely cross the barcode as show...

Страница 111: ...en spot onto the barcode image The barcode type and content data display on the screen The field of view changes its size as you move the reader closer or farther away from the barcode Scan symbols wi...

Страница 112: ...are decoding algorithms are executed to extract the data from the image The omni directional scanning does not require that the operator orient the barcode to align with the scan pattern To scan a bar...

Страница 113: ...s The aiming pattern is used to position the barcode or object within the field of view 4 Center the symbol in any orientation within the aiming pattern Ensure the entire symbol is within the rectangu...

Страница 114: ...ou move the reader closer or farther away from the barcode The aiming pattern is smaller when the imager is closer to the barcode and larger when it is farther from the barcode Scan symbols with small...

Страница 115: ...osoft website www microsoft com It is only compatible with Windows Vista and Windows 7 if you run Windows XP or earlier you have to download Microsoft ActiveSync You can establish a connection to your...

Страница 116: ...synchronizes the mobile computer automatically Microsoft Office Outlook emails and other information will appear on your device after synchronization NOTE The WDT92 running WEC7 does not come equipped...

Страница 117: ...nection You can use any standard USB charge communication cable to directly connect the WDT92 to a host computer and transfer data through the USB interface NOTE Connection through the cable complies...

Страница 118: ...ou can use the Wasp HandyLink cable 94A051970 to directly connect the WDT92 to a host computer to transfer data through the USB interface NOTE The HandyLink cable complies to USB 2 0 standard Host Com...

Страница 119: ...nsert the WDT92 mobile computer into the dock NOTE Connection through the dock complies to USB 2 0 standard NOTE The actual data transfer speed can be appreciably lower than the maximum theoretical sp...

Страница 120: ...icro USB host cable together with a standard USB cable if needed For all these devices maximum current draw must be less than 100mA A standard USB cable is needed only if the USB hard driver or flash...

Страница 121: ...ash memory device does not include its own cable with a A plug on it NOTE WDT92 works with most of the mentioned USB peripherals Wasp cannot guarantee the interoperability of WDT92 with all devices on...

Страница 122: ...The Single Slot Dock can be connected to the Host by means of a standard null modem cable such as Wasp 94A051020 CAB 427 for 9 pin connections Once the host computer has been turned on insert the WDT...

Страница 123: ...02 11 a b g n radio models can communicate with the host using the on board Wi Fi radio and an Access Point connected to a network For more information on this utility refer to WCU Wireless Configurat...

Страница 124: ...battery life the Bluetooth module is off by default To enable the Bluetooth open the Bluetooth Manager Window see Bluetooth Manager Device Setup on page 55 NOTE Suspending the terminal powers off the...

Страница 125: ...Connections User s Manual 119 NOTE Area coverage and Bluetooth radio performance may vary due to environmental conditions or interference caused by other devices microwave ovens radio transmitters etc...

Страница 126: ...me recommendations provided by Health Industry Manufacturers Associations for mobile phones Persons with pacemakers Should ALWAYS keep this device more than twenty five 25 cm from their pacemaker and...

Страница 127: ...ng your vehicle You should also consult the manufacturer of any equipment that has been added to your vehicle An air bag inflates with great force DO NOT place objects including either installed or po...

Страница 128: ...iquids explosive gases or materials with the device or its parts or accessories Areas with a potentially explosive atmosphere are often but not always clearly marked or shown Sparks in such areas coul...

Страница 129: ...cap battery 422 g 14 9 oz Pistol Grip with standard battery 482 g 17 0 oz Pistol Grip with hi cap battery 516 g 18 2 oz Display TFT Transflective LCD with 240 x 320 pixel resolution LED backlight and...

Страница 130: ...dels Wireless Communications Local Area Network WLAN TI Wi Link 8 IEEE 802 11a b g n Frequency Range Country dependent typically 2 4 and 5 GHz Cisco Compatible CCX v4 Security Personal Area Network WP...

Страница 131: ...al slot SDHC up to 32 GB Microprocessor TI OMAP4 1 GHz Memory RAM Memory 1 GB Flash Memory 8 GB partially used for firmware and reserved data Software Applications Pal Application Library pre licensed...

Страница 132: ...GS1 Composite Codes UPC EAN JAN Composites GS1 DataBar Composites and GS1 128 Composite Reading Performance 2D Imager Standard Range Megapixel sensor for extended range White LED Illumination Optical...

Страница 133: ...ry approvals for its intended use Enviromental Compliance Complies to EU RoHS Laser Classifications VLD Class 2 IEC EN60825 1 Compliant with 21 CFR 1040 10 except for deviations pursuant to laser noti...

Страница 134: ...Typical Working Ranges 3 mils Code 39 6 30 in 16 cm 5 mils Code 39 11 81 in 30 cm 10 mils Code 128 19 69 in 50 cm 13 mils EAN 25 20 in 64 cm 20 mils Code 39 47 24 in 120 cm Resolution mils Barcode Ty...

Страница 135: ...Technical Features User s Manual 129 13 mils EAN13 25 59 in 65 cm 15 mils Datamatrix 13 78 in 35 cm 20 mils Code 39 39 37 in 100 cm...

Страница 136: ...Test Codes 130 WDT92 Test Codes High Density Codes 0 25 mm 10 mils Code 39 17162 Interleaved 2 5 0123456784 Code 128 test...

Страница 137: ...Test Codes User s Manual 131 High Density Codes continued 0 25 mm 10 mils 80 EAN 13 80 EAN 8...

Страница 138: ...Test Codes 132 WDT92 Medium Density Codes 0 38 mm 15 mils Code 39 17162 Interleaved 2 5 0123456784 Code 128 test...

Страница 139: ...Test Codes User s Manual 133 Medium Density Codes continued 0 38 mm 15 mils 100 EAN 13 100 EAN 8...

Страница 140: ...Test Codes 134 WDT92 Low Density Codes 0 50 mm 20 mils Code 39 17162 Interleaved 2 5 0123456784 Code 128 test...

Страница 141: ...Test Codes User s Manual 135 Low Density Codes continued 0 50 mm 20 mils 120 EAN 13 120 EAN 8...

Страница 142: ...Test Codes 136 WDT92 2D Codes Datamatrix ECC200 Example Inverse Datamatrix ECC200 Example...

Страница 143: ...Test Codes User s Manual 137 NOTES...

Страница 144: ...he product contacts and plastics An antistatic cloth is preferable but you can also use a cotton cloth Avoid wool synthetic cloths or other materials that can cause electrostatic discharges If the con...

Страница 145: ...ntacts following the directions indicated by the red arrows Use care not to leave any cloth residue 4 Use a dry cloth to remove any dirt near the contacts area and to clean the plastic parts If the pl...

Страница 146: ...cohol solution 20 maximum 3 Gently rub the cloth back and forth ONLY along the contacts following the directions indicated by the red arrows Use care not to leave any cloth residue 4 Use a dry cloth t...

Страница 147: ...ghts Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work procedures CAUTION...

Страница 148: ...user Any tampering will invalidate the warranty When replacing the battery pack or at the end of the operative life of the WDT92 disposal must be performed in compliance with the laws in force in you...

Страница 149: ...source which supplies power directly to the unit via the micro USB connector of the cable The device could be also used with Certified Accessories Dock Cradle The Dock Cradle accessories are intended...

Страница 150: ...ight is visible to the human eye and is emitted from the window indicated in the figure below LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAX OUTPUT RADIATION 1 mW COMPLIANT WITH EN 60825...

Страница 151: ...Safety and Regulatory Information User s Manual 145 Laser Warning Label Printed Data Label Marks Label Scan Window...

Страница 152: ...E IL FASCIO APPARECCHIO LASER DI CLASSE 2 MASSIMA POTENZA MEDIA DI USCITA 1 mW LUNGHEZZA D ONDA EMESSA 630 680 nm CONFORME A EN 60825 1 2007 E EN 60825 1 2014 LASERSTRAHLUNG NICHT IN DER STRAHL BLINKE...

Страница 153: ...ough staring directly at the laser beam momentarily causes no known biological damage avoid staring at the beam as one would with any very strong light source such as the sun Avoid shining laser light...

Страница 154: ...afety and Regulatory Information 148 WDT92 WARNING Use of optical systems with the scanner will increase eye hazard Optical instruments include binoculars microscopes eye glasses and magnifying glasse...

Страница 155: ...in seguito ad una esposizione di breve durata evitare di fissare il raggio laser cos come si eviterebbe qualsiasi altra sorgente di luminosit intensa ad esempio il sole Evitare inoltre di dirigere il...

Страница 156: ...ory Information 150 WDT92 ATTENZIONE L uso di strumenti ottici assieme allo scanner pu aumentare il pericolo di danno agli occhi Tali strumenti ottici includono cannocchiali microscopi occhiali e lent...

Страница 157: ...kurzen Einstrahlungen bekannt sind sollten Sie es vermeiden f r l ngere Zeit in den Laserstrahl zu schauen genauso wenig wie in starke Lichtquellen z B die Sonne Vermeiden Sie es den Laserstrahl wede...

Страница 158: ...nformation 152 WDT92 ACHTUNG Die Verwendung von Optiksystemen mit diesem Scanner erh ht die Gefahr einer Augenbesch digung Zu optischen Instrumenten geh ren unter anderem Ferngl ser Mikroskope Brillen...

Страница 159: ...t constat la suite d une exposition au rayon laser Eviter de regarder fixement le rayon comme toute autre source lumineuse intense telle que le soleil Eviter aussi de diriger le rayon vers les yeux d...

Страница 160: ...nformation 154 WDT92 ATTENTION L utilisation d instruments optiques avec le scanneur augmente le danger pour les yeux Les instruments optiques comprennent les jumelles les microscopes les lunettes et...

Страница 161: ...cia de una exposici n de corta duraci n Eviten de mirar fijo el rayo l ser as como evitar an cualquiera otra fuente de luminosidad intensa por ejemplo el sol Adem s eviten de dirigir el rayo l ser hac...

Страница 162: ...grated in the 1D and 2D imager are classified as EXEMPT RISK GROUP according to IEC62471 ATENCI N El uso de sistemas pticos con el esc ner aumentar el riesgo de da os oculares Los instrumentos pticos...

Страница 163: ...indoor use when operated in the 5 15 to 5 25 GHz frequency range Changes or modifications made to this equipment not expressly approved by Wasp may void the FCC authorization to operate this equipment...

Страница 164: ...ul interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following m...

Страница 165: ...teur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement CAUTION i the device for operation in the band 5150 5250...

Страница 166: ...utilisateurs de radars de haute puissance sont d sign s utilisateurs principaux c d qu ils ont la priorit pour les bandes 5 250 5 350 MHz et 5 650 5 850 MHz et que ces radars pourraient causer du bro...

Страница 167: ...public listing www fcc gov under the FCC IDs specified in the FCC IC labeling section US and Canada For body worn operation this device has been tested and meets the FCC ISED RF exposure guidelines f...

Страница 168: ...smitted power as specified below Radio Technology Frequency Bands WLAN IEEE 802 11b g n SISO 20MHz channels bandwidth HT 20 MIMO support 20MHz channels bandwidth HT 20 2 4GHz Frequency Bands 2 412 2 4...

Страница 169: ...l support through its website Please check our website at www waspbarcode com under Support Training and click on the links indicated for further information including Online Support Center Updates Pa...

Страница 170: ...Reference Documentation 164 WDT92 NOTES...

Страница 171: ...nction programs that often ship with a larger product Programs such as Windows Calculator File Manager Control Panel and Notepad are examples of applets ASCII American Standard Code for Information In...

Страница 172: ...ure hardware and software Byte On an addressable boundary eight adjacent binary digits 0 and 1 combined in a pattern to represent a specific character or numeric value Bits are numbered from the right...

Страница 173: ...arpness is gradual on each side of the focused distance so that within the DOF the unsharpness is imperceptible under normal viewing conditions Dock A dock is used for charging the terminal battery an...

Страница 174: ...serves other mobile computers in a network providing services such as network control database access special programs supervisory programs or programming languages IEC International Electrotechnical...

Страница 175: ...cise electrical charges causing them to reflect light outside according to their bias They use little electricity and react relatively quickly They require external light to reflect their information...

Страница 176: ...s distinguished by a particular reading device or printed with a particular device or method RF Radio Frequency Scanner An electronic device used to scan barcode symbols and produce a digitized patter...

Страница 177: ...to be easily connected to a computer A plug and play interface it allows a device to be added without an adapter card and without rebooting the computer the latter is known as hot plugging The USB sta...

Страница 178: ...twork a network for interconnecting devices centered around an individual person s workspace in which the connections are wireless Typically a wireless personal area network uses some technology that...

Страница 179: ...Glossary User s Manual 173 NOTES...

Страница 180: ...p Barcode Technologies All rights reserved Logo of Wasp and Wasp bug are registered trademarks Wasp Barcode Technologies S r l 1400 10th Street Plano TX 75074 Telephone 866 547 9277 Fax 214 547 4101 8...

Отзывы: