Wasp WDT3250 RF Скачать руководство пользователя страница 4

Wasp Technologies -  WDT3250 RF Setup Guide 

 

  

2

 

Using the Summit Client Utility Software 

 
Summit Client Utility (SCU) provides a graphical user interface (GUI) for access to all of its functions.  
Access to these functions also is available through an application programming interface (API).  The API 
allows an application programmer to enable another utility to manage the radio. 

 

To open the SCU: 
• From 

the 

Start

 menu, select 

Programs

 

•  Select the directory called 

Summit

 

• Inside 

the 

Summit

 directory are two items: a directory for the storage of security certificates and an 

SCU icon.  To run SCU, double-click the SCU icon 

 

SCU has five windows: 

Main

Profile

Status

Diags

 (or Troubleshooting), and 

Global

.  Tabs enable 

easy navigation between windows.  Each window is described in more detail in this section.  Simply 
click on a tab name to view that window. 

Main Window 

Figure 1 below is an example of the 

Main

 window: 

 

 

Figure1: Main Window 

 

The features on the 

Main

 screen are: 

 
• 

Admin Login/Logout: 

To login to SCU as an administrator, you select this button when “Admin 

Login” is displayed and supply the correct admin password on the dialog box.  The default password 
is “SUMMIT” in all capital letters.  (The password can be changed through the Admin Password 
function on the Global Settings window.)  Once you are logged in as an administrator, clicking the 
button again logs you out as an administrator, leaving you with access only to end-user functions. 

• 

Enable/Disable Radio: 

When the radio is enabled, selecting this button disables it; when the radio is 

disabled, selecting this button enables it. 

• 

Active Profile:  

This field displays the name of the Active Profile.  You can change this to a different 

profile by clicking the down arrow and making a selection from the list of available profiles.  If you select 
“ThirdPartyConfig”, after the device goes through a power cycle, WZC is used for configuration of the 

Содержание WDT3250 RF

Страница 1: ...WDT3250 RF Setup Guide 2008 Wasp Technologies...

Страница 2: ...Wasp Technologies WDT3250 RF Setup Guide i Table of Contents Overview 1 Using the Summit Client Utility Software 2 Main Window 2 Profile Window 3 Status Window 5 Diags Window 6 Global Window 6...

Страница 3: ...uration monitoring and management application designed for Summit radio modules On Windows CE Mobile a service that displays a Windows System Tray icon that provides a visual status for the Summit rad...

Страница 4: ...in Window Figure 1 below is an example of the Main window Figure1 Main Window The features on the Main screen are Admin Login Logout To login to SCU as an administrator you select this button when Adm...

Страница 5: ...on the Main window the settings for that profile become active An administrator can define up to 20 profiles edit them and delete them on the Profile window in SCU Profile changes made on this screen...

Страница 6: ...e Credentials button appears When you tap Credentials a dialog box appears that enables you to define authentication credentials for that EAP type When you as an administrator select an encryption typ...

Страница 7: ...Status This field indicates the radio s current status Possible statuses are Down not recognized Disabled Not Associated Associated or EAP type Authenticated Device Name This section lists the follow...

Страница 8: ...nce the button is clicked its name and function will change to Stop Ping Moving to an SCU window other than Status or Diags also will stop the ping Pings will continue until you tap the Stop Ping butt...

Страница 9: ...nologies WDT3250 RF Setup Guide 7 Figure 5 Global window The default setting for each global setting ensures reliable operation in most environments Consult the user s guide for details on all global...