References
256
Wasp WDI7500/WWS750
Flash On Time
This feature specifies the ON time for the indicator LED while in Flash Mode.
The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in
100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad
the result with leading zeroes to yield two digits. For example: 0 = 00,
5 = 05, 20 = 20, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE barcode
to enter Programming Mode.
4. Scan the barcode: SELECT FLASH ON TIME SETTING.
5. Scan the appropriate two digits from the keypad in
representing the duration which was determined in the steps above.
You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar-
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See
for examples of how to set this
feature.
Table 42. Flash On Time Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
500ms
1,000ms (1 sec.)
5200ms (5.2
sec.)
9,900ms (9.9 sec.)
2
Divide by 100 (and pad
with leading zeroes to yield
two digits)
05
10
52
99
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT FLASH ON TIME SETTING
5
Scan Two Characters From
‘0’ and ‘5’
‘1’ and ‘0’
‘5’ and ‘2’
‘9’ and ‘9’
6
Scan ENTER/EXIT PROGRAMMING MODE
Содержание Wasp WDI7500
Страница 1: ...Wasp WDI7500 Wasp WWS750 2D Duraline USB or Wireless Barcode Scanner Product Reference Guide...
Страница 10: ...viii Wasp WDI7500 WWS750 NOTES...
Страница 282: ...Sample Barcodes 272 Wasp WDI7500 WWS750 Sample Barcodes continued Code 32 Codabar 13579 Code 93 Code 11 123456789...
Страница 308: ...Microsoft Windows Codepage 1252 Product Reference Guide 298 NOTES...