CHAPTER 1    INTRODUCTION

This manual provides all useful information regarding
configuration,

custom

configuration

and

configuration procedure. You are suggested to read
all information containing herein before starting to
configure your scanner. As stated, we recommend
that configuration, especially custom configuration,
better to be performed 
by experienced users, your dealer or your software
consultant.

1.1. Default Configuration

The operation parameters of the scanner are set to
defaults at the factory in order to suit for the most
popular  bar  code  data  collection  applications.

  * Emulation as keyboard wedge
  * IBM PC AT, PS/2 series computers
  * US keyboard layout
  * Data transmitted in lower case
  * Reading mode: Trigger on/good read off
  * Good reading beep active
  * Keyboard data terminator : CR
  * Keyboard number key: Alphanum
  * Red LED light on 

1.2 Custom Configuration

The scanner can be re-configured at any time for
your different application. You can change one or
several default parameters by scanning the labels
provided in this manual to fit our applications. For
entering our own custom configuration, please refer
to Chapter 2,3,4 and appendixes of this manual for
details.

Please, however, note that once the

configuration

is

re-programmed,

the

desired

parameters will be saved in the memory even after
the power is turned off.

1.3 Configuration Procedure

One or more parameters of the scanner can be
reconfigured to meet your need. The basic steps of
customs configuration are as under :

   1) Scan " START " label
   2) Scan desired parameters
   3) Scan " EXIT" label, otherwise proceed to the next 
        step 
   4) Scan " END" label

In order to have a better idea about all configuration
procedures, please refer to the Fig. 1, Flow Chart of
Configuration Procedure, which is on the overleaf of 
the  front  cover  of  this  manual.

All default parameters are marked with an asterisk "*"
in this manual. Generally, the defaults set in the
factory are:

7

8

Содержание CCD - 80SIR

Страница 1: ...uration Commands START To begin the configuration procedures END To finish the configuration procedures and save new parameters in memory ABORT To give up all parameters that you have just selected SE...

Страница 2: ...manual To avoid any misuse or misunderstanding we strongly suggest and recommend that the configuration manual should be used by either your dealer or your software consultant for proper set up and cu...

Страница 3: ...4 Buzzer Parameters 4 5 Other Parameters CHAPTER 5 USEFUL EXAMPLES CHAPTER 6 USB Connection APPENDICES A Keyboard Wedge Parameters Computer Type B Keyboard Wedge Parameters Keyboard Layout C Readable...

Страница 4: ...r selection Here are some suggestions about the way to hold the scanner in CCD 80SIR with no trigger you may using the better way to let your operating more easily 1 EASY WAY to hold the CCD 80SIR 2 C...

Страница 5: ...ndicator will light and the CCD scanner will beep to indicate a correct installation To install the scanner as a RS 232C device 1 2 Plug the phone jack of scanner cable into your CCD scanner Turn off...

Страница 6: ...a self test when the power is on If the CCD scanner does not read a barcode label please check the following list first If the barcode label is smeared or rough If the interface cable is firmly connec...

Страница 7: ...Affixing the CCD stand 6b 6c...

Страница 8: ...tion The scanner can be re configured at any time for your different application You can change one or several default parameters by scanning the labels provided in this manual to fit our applications...

Страница 9: ...Keyboard parameters include 1 Keyboard layout 2 Keyboard speed 3 Keyboard character delay 4 keyboard upper lower case 5 keyboard number keys 6 keyboard data terminator 1 Keyboard Layout US Germany Fr...

Страница 10: ...Keyboard Number Keys 6 Keyboard Data Terminator Min to Max 00 99 Define char delay Note For setting up please refer to the examples in Chapter 5 Lower Auto Upper Alphanum Numeric Pad CR SPACE ESC None...

Страница 11: ...232 Pin Assignment DUSB 9P Female 1 N C no connection 2 TXD 5 GND 7 CTS 8 RTS 9 VCC 5V DC Adapter 5v 10 150mA min RS 232C parameters include 1 Baud rate 2 Data bits 3 Parity 4 Handshaking protocol 5...

Страница 12: ...CE ESC STX ETX None CR LF TAB Ctrl C Xon Xoff 15 CHAPTER 3 BAR CODE SETTING The scanner can read almost all popular symbologies in the world Scan one or more codes from the following labels to meet yo...

Страница 13: ...SI Plessy China Postage and ISBN ISSN listed in page 25 Code 14 On Off Add on 2 5 17 3 1 CODE 39 Parameters These parameters include 1 Character set 2 Verify check digit 3 Transmit check digit 4 Trans...

Страница 14: ...length with minimum 4 and maximum 48 2 In order to suit your routine application you may also re define as fixed length up to 3 3 You may see examples in Chapter 5 for re definition 3 3 Industrial 2...

Страница 15: ...o Yes No Yes 3 Code Length Variable length Min Max 2 40 Note See examples in Chapter 5 for re definition Fixed length Custom define 3 5 Codabar Parameters 1 Transmit start stop characters 2 Type of st...

Страница 16: ...ond digit 3 Transmit check digit Yes No 2 Transmit Second Digit Yes No 3 Transmit Check Digit Yes No 3 7 UPC A Parameters 1 Transmit first digit 2 Transmit second digit 3 Transmit check digit 1 Transm...

Страница 17: ...IONAL SETTING This chapter provides you instructions for selecting optional parameters in order to fit your special requirements These options include reading modes code mark pre amble post amble buzz...

Страница 18: ...your definition Code Mark Parameters Code 39 IND 2 5 CODABAR EAN 8 Code 128 ITF 2 5 MTX 2 5 EAN 13 UPC A UPC E Note 1 Read code type and then CANCEL label 2 Please follow the rule for cancellation ste...

Страница 19: ...for A 6 A stand for j 5 8 stand for X Please take note in orders 4 1 6 A 5 8 2 Scan START label printed in the front cover of manual 3 Scan the provided pre amble label 4 Follow the order of 4 1 6 A...

Страница 20: ...II CODE TABLE START END SET 32 H L 0 1 2 3 4 5 6 7 0 NUL DLE SP 0 P p 1 SOH DC1 2 B R b r 2 STX DC2 1 A Q a q 3 ETX DC3 3 C S c s 4 EOT DC4 4 D T d t 5 ENQ NAK 5 E U e u 6 ACK SYN 6 F V f v 7 BEL ETB...

Страница 21: ...87 103 119 40 56 72 88 104 120 41 57 73 89 105 121 42 58 74 90 106 122 43 59 75 91 107 123 44 60 76 92 108 124 45 61 77 93 109 125 46 62 78 94 110 126 127 111 95 79 63 47 APPENDIX C OTHER OPTIONS In t...

Страница 22: ...al Latin America Poland Sweden Finland Belgium Denmark Norway Japan Holland Switzerland C Readable Code Code 93 On Off Code 11 On Off MSI Plessy On Off China Postage On Off Code IV On Off ISBN ISSN On...

Страница 23: ...e IV Code 11 China Postage CANCEL Note 1 Read code type just once a time and then CANCEL label afterwards F China Postage Parameters 1 Code Length Variable Length Min Max 2 40 2 Verify Check Digit Yes...

Страница 24: ...39 APPENDIX D HEX LABEL TABLE 0 1 2 3 4 5 6 7 8 9 A B C D E F EXIT...

Отзывы: