The current sensor does not work.
Is it programmed off? Is it programmed for 5 minute delay? See
Shock Sensor Adjustment section.
The current sensor can sense the domelight circuit more effectively if the RED (+) 12V input wire is con-
nected directly to the dome light positive circuit. This is not necessary in most cases, but will help when
the dome light circuit is extremely low current.
The shock sensor is not sensitive enough.
The mounting of the control unit is critical to shock sensor performance. If relocation of the control unit
does not improve performance of the sensor, the angle of the unit and the bracket may be changed as
shown below. Remember, the siren must be protected against water damage and the more the angle is
changed, the easier it is for water to collect in the siren housing.
After programming, the remote does not arm or disarm the system.
Follow the instructions for Transmitter/Receiver Learn Routine
™
carefully. See
Transmitter/Receiver Learn
Routine section. The remote button must be pressed three separate times in order for the system to learn
the transmitter code properly.