Machine displays
error code 05E
Is machine
empty of water
at start of
program?
Yes
No
Empty water and try
again
Is dis-
charge sy-
stem free of
foreign matter
(clear passage
for discharge
water)?
Yes
No
Clean discharge
system. For pump
machine, check also
pump housing (coins,
hair clips etc)
Can dis-
charge ("drain")
be operated
in SE?
Note!
No
Yes
No
Yes
Change drain
valve/pump
Can the relay
on programmer
be operated in SE?
Note!
Yes
Change PCB
Change wiring
No
Water level indicated right at start of program
Fault-finding
12
Continue on
page 13
Note!
Machine door
must be closed
when service
program in use
Are connec-
tions to drain
valve/pump clean
and free of
foreign
matter?
Yes
Rectify
No
Pump
machine:
Is voltage absent at
drain pump?
Non-pump machine:
Is there constantly
voltage at drain
valve?
Note!
Machine door
must be closed
when service
program in use
95.08