background image

4

LOCA

LOCA

LOCA

LOCA

LOCATION OF YOUR DR

TION OF YOUR DR

TION OF YOUR DR

TION OF YOUR DR

TION OF YOUR DRYER

YER

YER

YER

YER

DO NOT INST

DO NOT INST

DO NOT INST

DO NOT INST

DO NOT INSTALL YOUR DR

ALL YOUR DR

ALL YOUR DR

ALL YOUR DR

ALL YOUR DRYER:

YER:

YER:

YER:

YER:

1. In an area exposed to dripping water or outside weather

conditions.

2. In an area where it will come in contact with curtains, drapes,

or anything that will obstruct the flow of combustion and
ventilation air.

3. On carpet. Floor MUST

MUST

MUST

MUST

MUST be solid with a maximum slope of 1

inch (2.54 cm).

INST

INST

INST

INST

INSTALLA

ALLA

ALLA

ALLA

ALLATION IN RECESS OR CLOSET

TION IN RECESS OR CLOSET

TION IN RECESS OR CLOSET

TION IN RECESS OR CLOSET

TION IN RECESS OR CLOSET

1. A dryer installed in a bedroom, bathroom, recess or closet,

MUST

MUST

MUST

MUST

MUST be exhausted outdoors.

2. No other fuel burning appliance shall be installed in the

same closet as the Gas dryer.

3. Your dryer needs the space around it for proper ventilation.

DO NOT INST

DO NOT INST

DO NOT INST

DO NOT INST

DO NOT INSTALL YOUR DR

ALL YOUR DR

ALL YOUR DR

ALL YOUR DR

ALL YOUR DRYER IN A CLOSET WITH A

YER IN A CLOSET WITH A

YER IN A CLOSET WITH A

YER IN A CLOSET WITH A

YER IN A CLOSET WITH A

SOLID DOOR.

SOLID DOOR.

SOLID DOOR.

SOLID DOOR.

SOLID DOOR.

CLOSET DOOR

CLOSET DOOR

CLOSET DOOR

CLOSET DOOR

CLOSET DOOR

1" (2.54 cm)

1" (2.54 cm)

1" (2.54 cm)

1" (2.54 cm)

1" (2.54 cm)

0" (0  cm)

0" (0  cm)

0" (0  cm)

0" (0  cm)

0" (0  cm)

4. A minimum of 120 square inches (774.2 square cm) of

opening, equally divided at the top and bottom of the door,
is required. Air openings are required to be unobstructed
when a door is installed. A louvered door with equivalent
air openings for the full length of the door is acceptable.

MINIMUM INST

MINIMUM INST

MINIMUM INST

MINIMUM INST

MINIMUM INSTALLA

ALLA

ALLA

ALLA

ALLATION CLEARANCES (Inches)

TION CLEARANCES (Inches)

TION CLEARANCES (Inches)

TION CLEARANCES (Inches)

TION CLEARANCES (Inches)

FRONT

SIDES

REAR

TOP

Alcove

0 (0 cm)

0 (0 cm) 0 (0 cm) 15 (38.1 cm)

Closet

1 (2.54 cm) 0 (0 cm) 0 (0 cm) 15 (38.1 cm)

Closet door ventilation required: 2 louvered openings each 60
square inches (387 square centimeters) — 3 inches (7.6 cm)
from bottom and top of door.

THIS DRYER MUST BE EXHAUSTED OUTDOORS.

THIS DRYER MUST BE EXHAUSTED OUTDOORS.

THIS DRYER MUST BE EXHAUSTED OUTDOORS.

THIS DRYER MUST BE EXHAUSTED OUTDOORS.

THIS DRYER MUST BE EXHAUSTED OUTDOORS.

5. The following illustrations show minimum clearance

dimensions for proper operation in a recess or closet
installation.

60 SQ. IN.

60 SQ. IN.

60 SQ. IN.

60 SQ. IN.

60 SQ. IN.
(387.1 SQ. CM)

(387.1 SQ. CM)

(387.1 SQ. CM)

(387.1 SQ. CM)

(387.1 SQ. CM)

60 SQ. IN.

60 SQ. IN.

60 SQ. IN.

60 SQ. IN.

60 SQ. IN.
(387.1 SQ. CM)

(387.1 SQ. CM)

(387.1 SQ. CM)

(387.1 SQ. CM)

(387.1 SQ. CM)

15" (38.1 cm)

15" (38.1 cm)

15" (38.1 cm)

15" (38.1 cm)

15" (38.1 cm)

0" (0 cm)

0" (0 cm)

0" (0 cm)

0" (0 cm)

0" (0 cm)

Содержание Gas & Electric Gas & Electric Dryer

Страница 1: ...hese instructions This will simplify the installation and ensure the dryer is installed cor is installed cor is installed cor is installed cor is installed corr r r r rectly and safely ectly and safely ectly and safely ectly and safely ectly and safely Leave these instr Leave these instr Leave these instr Leave these instr Leave these instructions near the Dr uctions near the Dr uctions near the D...

Страница 2: ... exhaust system MUST be exhausted to the outside of dryer exhaust system MUST be exhausted to the outside of dryer exhaust system MUST be exhausted to the outside of the building the building the building the building the building Do not allow combustible materials for example clothing draperies curtains paper to come in contact with exhaust system The dryer MUST NOT MUST NOT MUST NOT MUST NOT MUS...

Страница 3: ...l to or less than 1 2 psig 3 45 kPa INSTALL MALE FITTINGS IN CORRECT DIRECTION In installations where the exhaust system is not described in the charts the following method must be used to determine if the exhaust system is acceptable 1 Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer 2 Set the dryer timer and temperature to air fluff cool ...

Страница 4: ...OSET DOOR CLOSET DOOR CLOSET DOOR CLOSET DOOR CLOSET DOOR 1 2 54 cm 1 2 54 cm 1 2 54 cm 1 2 54 cm 1 2 54 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 4 A minimum of 120 square inches 774 2 square cm of opening equally divided at the top and bottom of the door is required Air openings are required to be unobstructed when a door is installed A louvered door with equivalent air openings for the full length ...

Страница 5: ...y lay the dryer on its left side and remove foam shipping base To prevent damage do not use the control panel or coin meter housing as a means to pick up or move the dryer NOTE NOTE NOTE NOTE NOTE On under counter model clothes dryers the top panel may be removed for installation 2 Return the dryer to an upright position PACKING FOAM SHIPPING REMOVE 4 SCREWS ONE FROM EACH HINGE FIRST ROUGH IN DIME...

Страница 6: ...trical shock Do not use an aluminum wired receptacle with a copper wired power cord and plug or vice versa A chemical reaction occurs between copper and aluminum and can cause electrical shorts The proper wiring and receptacle is a copper wired The proper wiring and receptacle is a copper wired The proper wiring and receptacle is a copper wired The proper wiring and receptacle is a copper wired Th...

Страница 7: ...OR 3 WIRE SYSTEM FOR 3 WIRE SYSTEM ELECTRIC ELECTRIC ELECTRIC ELECTRIC ELECTRIC Dryer Dryer Dryer Dryer Dryer 1 Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L listed strain relief into the power cord entry hole of the mounting bracket Finger tighten the nut only at this time 3 Thread a ...

Страница 8: ...aker fuse box Before operating the dryer make sure the dryer area is clear and free from combustible materials gasoline and other flammable vapors Also see that nothing such as boxes clothing etc obstructs the flow of combustion and ventilation air 6 Run the dryer through a cycle check for proper operation NOTE NOTE NOTE NOTE NOTE On gas dryers before the burner will light it is necessary for the ...

Отзывы: