background image

Installation manual

35

9.5.2

Central payment (2J)

The central payment or booking system shall transmit an active (high) signal to the machine once permission has
been granted to start the machine. The signal must remain active (high) during drying. When the signal gets inactive
(low) the machine will abort ongoing program and enter cooling. The signal can be either 230V or 24V. In order to re-
ceive a feedback signal once the machine has started, 230V or 24V must be connected to connection 19. The feed-
back signal remains active (high) during the entire program.

P

ro

g

ra

m

 r

u

n

fig.7439

Содержание D7-290

Страница 1: ...Installation manual Tumble dryer D7 290 Type N2 Original instructions 438905403 EN 2023 02 20...

Страница 2: ......

Страница 3: ...fier 24 8 Gas connection 25 8 1 Fasten the label 25 8 2 General 25 8 3 Gas installation 26 8 4 Table of pressure and adjustment 27 8 5 Test run 28 8 6 Converting instructions 28 8 7 Data label 30 9 El...

Страница 4: ......

Страница 5: ...st not be installed behind a lockable door a sliding door or a door with a hinge on the opposite side to that of the machine in such a way that a full opening of the machine is restricted If the machi...

Страница 6: ...owing countries AT BE BG HR CY CZ DK EE FI FR DE GR HU IS IE IT LV LT LU MT NL NO PL PT RO SK SI ES SE CH TR UK The appliance can be used in public areas This appliance can be used by children aged fr...

Страница 7: ...se of doubt the installer shall contact the supplier The appliance should be installed on non flammable materials for the floor worktop and or wall close to the appliance if required If you can smell...

Страница 8: ...7 6 F G H I 3 4 J K L M N 5 O fig 7252 1 Operating panel 2 Door opening 580 mm 3 Electrical connection 4 Gas connection 5 Exhaust connection 6 Steam in 7 Steam out A B a B b C D E mm 715 1210 1360 169...

Страница 9: ...0 Hz 60 Hz m3 h 690 690 Maximum static back pressure Electric 50 Hz 60 Hz Pa 400 700 Maximum static back pressure Gas 50 Hz 60 Hz Pa 400 700 Maximum static back pressure Steam 50 Hz 60 Hz Pa 600 1100...

Страница 10: ...the machine and two in the back of the machine Remove the lower front panel and remove the two bolts in the front of the machine Remove the low er rear panel and remove the two bolts in the back of t...

Страница 11: ...r packaging 4 5 6 7 3 1 2 fig X02402 Fig Description Code Type 1 Wrapping film LDPE 4 Plastics 2 Corner protection PS 6 Plastics 3 Cardboard packaging PAP 20 Paper 4 Pallet FOR 50 Wood 5 Screw FE 40 S...

Страница 12: ...the gap above the machine Min required clearance 0 mm Note The machine should be positioned so that there will be enough space for working both for the user and service personnel Respecting the given...

Страница 13: ...ndation Fasten the four fittings A to the foundation using four x M10 set screws B If the four fittings are not supplied order kit No 487193545 Fasten the machine to the fittings 15 3 mm 9 16 inch 43...

Страница 14: ...foundation The clips shall be fastened with at least M10 bolts B If the clips are not supplied order kit No 487193544 Fasten the machine to the clips Note Marine installation is not applicable for ga...

Страница 15: ...7166 Remove the screws on the front panel and carefully loosen the panel Push the door switch cable down through the hole in order to access the cable and then disconnect the cable Remove the panel fi...

Страница 16: ...16 Installation manual Loosen the nuts and move the two brackets to the opposite side fig 7171 Move the door switch on the front panel 1 2 3 4 fig 7172...

Страница 17: ...witch cable and push the cable in over the drum and pull it upwards fig 7549 Remount the front panel Ensure that the door switch cable does not get damaged when remounting the front panel Fasten the h...

Страница 18: ...The heated air passes through the garments and the drum holes The air then flows out through a lint filter positioned below the drum Then the air is evacuated through the fan and exhaust system Dimens...

Страница 19: ...atted covers often block half of the total fresh air vent area Remember to take this into account 6 3 Exhaust duct Only rigid or flexible metal duct should be used for exhausting Plastic ducting is no...

Страница 20: ...0 63 0 98 0 98 1 56 1 56 1 56 2 51 Minimum area of fresh air intake m2 0 03 0 06 0 09 0 12 0 15 0 18 0 21 0 24 0 27 0 3 The exhaust duct diameter must not be reduced 6 5 Exhaust dimensioning It is imp...

Страница 21: ...the connection is tight to prevent air leakage Loosen the screws on the damper and open the damper B as much as possible A B fig 7525 Measure with a pressure measuring instrument manometer with an emp...

Страница 22: ...sert one end of the hose in the hole hold the hose according to the picture so that the water is in level Start the machine and measure the difference between the water in one of the hose ends with th...

Страница 23: ...is recommended to in stall a steam trap F 5 6 A B D E C F fig 7194B Attach the pressure hoses to the machines inlet and outlet connecting branches It is important to support the inlet and the outlet c...

Страница 24: ...me way A Hang the calorifier on the bottom supporting rail on the machine Hold the calorifier towards the machine and remount the supporting rail Make sure that it grasps the calorifier Fasten the cal...

Страница 25: ...Art No GB IE Read the technical instructions before installing the appli ance Read the user instructions before lighting the appliance This appliance may only be installed in a room if the room meets...

Страница 26: ...L Albania IE Ireland AT Austria IS Iceland BE Belgium IT Italy BG Bulgaria LT Lithuania CH Switzerland LU Luxembourg CY Cyprus LV Latvia CZ Czech Republic MK Republic of Macedonia DE Germany MT Malta...

Страница 27: ...035 490375645 FI NL RO BE CH CZ IE IT ES FR GR GB HR LT NL PL PT SI SK AT CH DE NL LU SK Natural gas Gas category Inlet pressure mbar Nozzle pres sure mbar Nozzle size mm Air reducing restriction plat...

Страница 28: ...ng screw 4 behind the cover screw 3 Replace the cover screw 3 if removed Check that the gas is burning evenly The blue flame on the burner is preferred 2 3 4 fig 7120 Note After connection all joints...

Страница 29: ...ram with heat Start the machine Set the correct nozzle pressure according to the table on setting screw 4 under the cover screw 3 2 3 4 fig 7120 Check that the gas flame burns evenly Mount the cover s...

Страница 30: ...e Model Voltage Rated Input For safety reasons use only genuine spare parts Made in Sweden Electrolux Professional AB 341 80 Ljungby Sweden Product no Serial no Program OC Type WXXXXX 9868XXXXXX 09XXX...

Страница 31: ...ensure that the appropriate type of breaker is chosen and that the dimensioning is correct for maximum reliability connect only one machine per earth leakage circuit breaker it is important that the e...

Страница 32: ...e supply unit Connect the earth and other wires as shown 3AC 3AC L1 L2 L3 3NAC 3NAC L1 L2 L3 N When the installation is completed remount the cover panel and check That the drum is empty That the mach...

Страница 33: ...5 9 8 14 3 50 63 220 230V 3 50 60 13 5 18 0 14 3 18 8 50 50 240V 3 50 60 13 5 18 0 14 3 18 8 35 50 380 400V 3N 3 50 60 13 5 18 0 14 3 18 8 25 32 415V 3N 3 50 60 13 5 18 0 14 3 18 8 20 32 440V 3 60 13...

Страница 34: ...system must transmit a start pulse 300 3000 ms 500 ms is recommended with a minimum pause of 300 ms 500 ms is recommended between two pulses The start pulse can be either 230V or 24V In order to rece...

Страница 35: ...chine The signal must remain active high during drying When the signal gets inactive low the machine will abort ongoing program and enter cooling The signal can be either 230V or 24V In order to re ce...

Страница 36: ...3 External coin meter Central payment 2K The signal received from external coin meters must be a pulse between 300 3000 ms 500 ms is recommended with a minimum pause of 300 ms 500 ms is recommended b...

Страница 37: ...rogram is reduced or the time is increased on time programs by the percent age entered in the price programming menu fig 7441 9 6 Option 9 6 1 External connection 100 mA A special connection terminal...

Страница 38: ...essages program names etc will be presented in 10 2 Set time and date Select YES and press the start button to get to the TIME DATE menu Activate the SET TIME menu and set the correct time Save the se...

Страница 39: ...machine Check if the micro switches are working properly The machine must stop if the door is opened Check the direction of rotation only on machines with 3 phase power supply Demount the lower back p...

Страница 40: ...e OK the machine is now ready to be used If some of the tests failed or deficiencies or errors are detected please contact your local service organisation or dealer The installer shall instruct the us...

Страница 41: ...ycled and that the refrigerator and heat pump components are special waste assimilable with urban waste The symbol on the product indicates that this product should not be treated as domestic waste bu...

Страница 42: ......

Страница 43: ......

Страница 44: ...Electrolux Professional AB 341 80 Ljungby Sweden Share more of our thinking at www wascomat com...

Отзывы: