  Operating Manual Wärtsilä JOVYLINE 625/1200/2200 BAX 3522 E                              page 14 

 

 
9. Replacing the batteries 

 

The battery works at least 3 years faultless before its replacing is necessary.  
For replacing please act as following: 

 

Secure that the UPS is switched-off, that the UPS is disconnected from mains and 
that each leaving wires such as load, EDV, telephone etc. are disconnected. 

 

1.  Remove the 4 screws at the UPS bottom sheet and store them. 

 

2.  Remove the upper cover sheet carefully. Don’t touch parts inside the UPS before you 

have disconnect the battery. 

 

3.  Remove the battery connection cables from the battery poles. 

 

4.  Now you can remove the battery easily. 

 

Attention: 

Lead the battery to a suited recycling circle. Don’t throw the battery into fire 
(danger of explosion). Avoid short circuit of the battery poles (danger of burns 
and explosion). Before works take off every decoration things such as rings, 
bracelets etc. (danger of short circuit and burns) 

 

5.  Place the new batteries in the same position as the old ones. 

Connect the battery wiring to the battery again. + = red wiring, - = black wiring 

 

6.  Screw on the cap of the cabinet. 

 

7.  Follow the instructions of the manual to put the UPS into operation again. 
 

10. Troubleshooting 

 

Problem 

  Possible 

reason 

   Solution 

 
UPS doesn’t start   

ON/OFF push button isn’t pressed 

push the button 1 sec  

LED doesn’t lighten  

or pressed 

to 

short 

   at 

least 

 

 

 

 

Battery voltage is lower than 10 V 

load the battery  

          4 

hours 

at 

least 

 
UPS only works in   

mains cable is loose 

 

 

put in the mains cable 

battery operation 

 

AC fuse defect 

 

 

 

change the fuse 

Mains voltage is to high 

 

 

establish normal  
mains voltage 

 

 

 

 

faults in the electronic system 

 

dial our service hotline  

 
time of emergency -  

battery isn’t charged completely   

charge the battery 

current 

is 

to 

short 

       4 

hours 

at 

least 

 

 

 

 

faults in the electronic system  

 

dial service hotline 

buzzer 

on 

permanent 

 

overload 

    remove 

unimportant 

alarm   

 

 

 

 

 

 

 

 

loads 

 

Red LED lightens up 

battery fault   

 

 

 

replace the battery 

 

UPS doesn’t feed load 

load is connected at the wrong    

use the both socket 

socket 

     as 

described 

in 

item 

11 

socket: „surge protection“   

 

page 10 

Содержание Jovyline 1200

Страница 1: ...BAX 3522 E Operating Manual UPS Systems W rtsil JOVYLINE 625 1200 2200...

Страница 2: ...before installation Pay attention to each special hint within the separate chapters to avoid later disturbances of the device right from the start In case of problems please contact our Service depart...

Страница 3: ...625 1200 2200 7 4 Installation 11 5 Operation of the UPS system 12 6 Alarms 13 7 Software options 13 8 Computer interface connection 14 9 Replacing of batteries 14 10 Troubleshooting 15 _____________...

Страница 4: ...itches off immediately or input protection gets released Input protection Protection against overload and short circuit Type of battery Lead battery closed maintenance poor 12V 7Ah JOVYLINE 625 24V 7A...

Страница 5: ...s bracelets etc at your arms and hands which could lead to a short circuit at the poles of the battery A short circuit on the battery can produce a very high short circuit current which leads usually...

Страница 6: ...ltage at the output socket is constant within separate voltage steps Please take the values out of table 1 on page 4 of this manual Production of these UPS systems is subjected to a strict quality con...

Страница 7: ...in its capacity the LED lightens up You have to replace the battery 2 Battery feeds load yellow LED If the load is fed by the battery the yellow LED lightens up 3 Mains OK green LED If the input volta...

Страница 8: ...ns the standardised RS 232 interface and works under the operation systems Novell Unix DOS Windows and others 6 Output sockets 7 Mains input socket with mains fuse 8 Socket for telephone modem with sp...

Страница 9: ...value The load is fed with normal voltage 3 Battery feeds load yellow LED If the battery feeds the load the yellow LED lightens up 4 AVR automatic voltage regulation yellow LED The LED lightens up if...

Страница 10: ...protection against voltage transients for modem network and telephone offers a completely safe internet connection 6 USV Port For communication between UPS and Computer 7 Output sockets Normal Versio...

Страница 11: ...PC with the RS232 interface by the cable enclosed 4 4 Connection of external battery blocks optional Before connection of the battery block secure that the battery plug and the connection cable are c...

Страница 12: ...UPS You can use the self test of the UPS to get a statement of the UPS function and battery function To start the self test you have to push the push button ON OFF during normal operation of the UPS i...

Страница 13: ...o remove parts of the load or replace the UPS by a bigger one Even consumers with a high peak current absorption such as laser printer plotter or faxes lead to an overload of the UPS Therefore it s ad...

Страница 14: ...nd burns 5 Place the new batteries in the same position as the old ones Connect the battery wiring to the battery again red wiring black wiring 6 Screw on the cap of the cabinet 7 Follow the instructi...

Отзывы: