10. TROUBLESHOOTING AND REMEDY 

Problem 

Fault Cause 

Remedy 

The diesel engine will not 
start 

Insufficient fuel  

Refill with fuel 

Fuel tap is not at ON position  Turn it to the 'ON' position 
Fuel injection pump does not 
deliver the fuel or deliver 
insufficient fuel 

Remove the injector pump 
and have tested. 

The governer lever is not at 
START position 

Set the lever to START 
position 

Check the engine oil level 

The specified oil level should 
be to the upper level. 

The injector is full of carbon 

Clean the injector 

The starter motor turns too 
slowly 

Check battery charge and 
12v connections - replace 
starter motor 

The battery is flat 

Charge it or replace it with a 
new one 

The generator is not 
producing power 

Main breaker switch has not 
been turned on 

Turn the main breaker 
switch to the 'ON' position 

Alternator brushes worn 

Replace the brushes 

The contact in the socket is 
not good 

Ensure plugs are fully 
inserted into sockets 

The rated speed is excessive 

Adjust engine speed to 
produce 52hz with no load 

AVR is damaged 

Replace the AVR 

 

Содержание DG6700

Страница 1: ...DG6700 DIESEL GENERATOR OWNERS MANUAL BEFORE OPERATING THIS EQUIPMENT PLEASE READ THESE INSTRUCTIONS CAREFULLY...

Страница 2: ......

Страница 3: ...ollow these warnings properly can result in property damage serious injury or death Read all labels and this user s manual before operating this generator Only operate this machine is well ventilated...

Страница 4: ...the engine body becomes very hot whilst the engine is running or just after running To prevent any burns do not touch these parts during these times 4 Electric Shocks Short Circuits To avoid electric...

Страница 5: ...up to 3 times the rated wattage to start Do not exceed the specified current limit of any socket Do not connect the generator to a household circuit of a house or building unless it is through a main...

Страница 6: ...for Starting 7 4 Starting the Generator 10 5 Operating the Generator 11 6 Load 12 7 Stopping the Generator 13 8 Periodic Checks and Service 14 9 Long term Storage 17 10 Troubleshooting and Remedy 18...

Страница 7: ...AND DATA Model D Generator Rated Frequency Hz 50 Max Power KW kVA 5 6 Voltage AC V 1 W Engine speed r min 3 00 DC Output 12v Run time hour E Engine Model E Weight kg 1 Dimensions LxWxH mm 910 x 5 x 7...

Страница 8: ...cap is securely closed after refuelling Take care not to spill fuel when refuelling If any fuel is spilled make sure the area is clean and dry before starting the engine 3 2 Check and Refill the Engin...

Страница 9: ...hours as required the risk of crankshaft bearing failure piston seizure piston ring sticking and accelerated wear of the cylinder liner main bearing and failure of other moving components increases s...

Страница 10: ...abinet door for daily inspection Turn the lever counter clockwise and raise the door 2 Loosen the bolt of the air cleaner cover to check the air cleaner 3 6 Break in Period Operation The first 20 hour...

Страница 11: ...3 Turn the starting key clockwise to the START position Remove your hand from the key as soon as the engine starts If the engine does not start after 10 seconds wait 15 seconds before trying again If...

Страница 12: ...battery 3 If the battery voltage is too low it will require charging before use 4 Keep the battery in a cool dry place It is important to clean the battery every three months and charge every six mont...

Страница 13: ...me to fully cool down Never refuel the fuel tank whilst the engine is still running 6 LOAD Do not start 2 or more appliances simultaneously start them one by one Do not use floodlights together with o...

Страница 14: ...ry in a well ventilated area Before charging remove the cap from each cell of the battery and ensure the electolyte level is correct Stop charging if the electrolyte temperature exceeds 45 C 6 3 Elect...

Страница 15: ...stop the engine with the decompression lever Do not stop the generator when under load Serious damage to the alternator and the AVR may occur 8 PERIODIC CHECKS AND SERVICE Periodic checks and service...

Страница 16: ...Yes Replace if necessary Adjust clearance of intake exhaust valves Yes First Time Yes Grind intake exhaust valves Yes Replace piston rings Yes Check battery condition Yes Check carbon brushes and sli...

Страница 17: ...nce 1 Adjust the clearance of the intake exhaust valves 2 Grind the intake exhaust valves 3 Replace the piston rings 4 Check injector nozzle All of these operations require special tools contact us fo...

Страница 18: ...t smoke or allow flames or sparks near the battery especially during charging 8 8 Check the alternator carbon brushes and slip rings Check the generators carbon brushes and slip rings regularly Readju...

Страница 19: ...fied oil level should be to the upper level The injector is full of carbon Clean the injector The starter motor turns too slowly Check battery charge and 12v connections replace starter motor The batt...

Страница 20: ......

Страница 21: ...21 12 Service Record Sheet Date Hours Maintenance undertaken Name...

Страница 22: ...22 13 Notes...

Страница 23: ...defects only not wear and tear The following are not covered under warranty Damage caused by improper use dropping wrongly adjusting or failing to follow the operating and service requirements e g lac...

Страница 24: ...R TECH DEPARTMENT Warrior Generators Unit 27 Salisbury Road Haydock Industrial Estate St Helens WA11 9XG United Kingdom Tel 44 0 1942 528271 For any technical or faults please contact warrior direct o...

Отзывы: