Warren rupp SANDPIPER SH2-M Скачать руководство пользователя страница 2

sandpiperpump

.

com

sh2mdl7sm-rev1218

Model SH2-M 

IMPORTANT

Read the safety warnings and instructions in this manual 

before pump installation and start-up. Failure to comply with 

the recommendations stated in this manual could damage the 

pump and void factory warranty.

When used for toxic or aggressive fluids, the pump should 

always be flushed clean prior to disassembly.

Airborne particles and loud noise hazards. Wear eye and ear 

protection.

Before maintenance or repair, shut off the compressed air line, 

bleed the pressure, and disconnect the air line from the pump. 

Be certain that approved eye protection and protective clothing 

are worn at all times. Failure to follow these recommendations 

may result in serious injury or death.

When the pump is used for materials that tend to settle out 

or solidify, the pump should be flushed after each use to 

prevent damage. In freezing temperatures the pump should be 

completely drained between uses.

Before pump operation, inspect all fasteners for loosening 

caused by gasket creep. Retighten loose fasteners to prevent 

leakage. Follow recommended torques stated in this manual.

CAUTION

WARNING

Nonmetallic pumps and plastic components are not UV 

stabilized.  Ultraviolet radiation can damage these parts and 

negatively affect material properties. Do not expose to UV light 

for extended periods of time.

In the event of diaphragm rupture, pumped material may enter 

the air end of the pump, and be discharged into the atmosphere. 

If pumping a product that is hazardous or toxic, the air exhaust 

must be piped to an appropriate area for safe containment.

This pump is pressurized internally with air pressure 

during operation. Make certain that all fasteners and piping 

connections are in good condition and are reinstalled properly 

during reassembly.

Take action to prevent static sparking. Fire or explosion can 

result, especially when handling flammable liquids. The pump, 

piping, valves, containers and other miscellaneous equipment 

must be properly grounded.

Safety Information

ATEX Pumps - Conditions For Safe Use

Use safe practices when lifting

kg

R E C YC L I N G 

Many components of SANDPIPER

®

 AODD 

pumps are made of recyclable materials.  

We encourage pump users to recycle worn 

out parts and pumps whenever possible, 

after any hazardous pumped fluids are  

thoroughly flushed.

WARNING

The use of non-OEM replacement parts will void (or negate) 

agency certifications, including CE, ATEX, CSA, 3A and EC1935 

compliance (Food Contact Materials).  Warren Rupp, Inc. cannot

 

ensure nor warrant non-OEM parts to meet the stringent 

requirements of the certifying agencies. 

1. 

 

Ambient temperature range is as specifi ed in tables 1 to 3 on the next page 

(per Annex I of DEKRA 18ATEX0094X)

2. 

 

ATEX compliant pumps are suitable for use in explosive atmospheres when the equipment is properly grounded in  

   

accordance with local electrical codes

3. 

 

Non-Metallic ATEX Pumps only — See Explanation of Pump Nomenclature / ATEX Details Page

   

Conductive Polypropylene, conductive Acetal or conductive PVDF pumps are not to be installed in applications where the  

   

pumps may be subjected to oil, greases and hydraulic liquids.

4. 

 

The optionally provided solenoids shall be protected by a fuse corresponding to its rated current (max 3*Irat according  

   

to EN 60127) or by a motor protecting switch with short circuit and thermal instantaneous tripping (set to the rated  

   

current) as short circuit protection. For solenoids with a very low rated current, a fuse with the lowest current value  

   

according to the indicated standard will be suffi  cient. The fuse may be accommodated in the associated supply unit  

   

or shall be separately arranged. The rated voltage of the fuse shall be equal or greater than the stated rated voltage of the  

   

solenoid. The breaking capacity of the fuse shall be as high as or higher than the maximum expected short circuit current  

   

at the location of the installation (usually 1500 A). The maximum permissible ripple is 20% for all dc solenoids.

  

*Not applicable for all pump models — See Explanation of Pump Nomenclature / ATEX Details Page

5.  

When operating pumps equipped with non-conductive diaphragms that exceed the maximum permissible projected area,  

   

as defi ned in EN ISO 80079-36 : 2016 section 6.7.5 table 8, the following protection methods must be applied

   

- Equipment is always used to transfer electrically conductive fl uids or 

   

- Explosive environment is prevented from entering the internal portions of the pump, i.e. dry running.

6.  

Pumps provided with the pulse output kit and used in the potentially explosive atmosphere caused by the presence of  

   

the combustible dust shall be installed in such a way that the pulse output kit is protected against impact

  

*Not applicable for all pump models — See Explanation of Pump Nomenclature / ATEX Details Page

UNIVERSAL ALL AODD

Содержание SANDPIPER SH2-M

Страница 1: ...ion 800 N Main St Mansfield Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM 2017 Warren Rupp Inc Certified Quality ISO 9001 Certified ISO 14001 Certified SERVICE OPERATING MAN...

Страница 2: ...d fluids are thoroughly flushed WARNING The use of non OEM replacement parts will void or negate agency certifications including CE ATEX CSA 3A and EC1935 compliance Food Contact Materials Warren Rupp...

Страница 3: ...to 50 C 20 C to 100 C T5 T100 X Ambient Temperature Range C Process Temperature Range C 20 C to 60 C 20 C to 150 C 1 Per CSA standards ANSI LC6 2018 US Canadian Technical Letter R14 G Series Natural...

Страница 4: ...uide Troubleshooting Guide SECTION 3 EXPLODED VIEW 8 Composite Repair Parts Drawing Composite Repair Parts List Down Ported Option Drawing Material Codes SECTION 4 AIR END 12 Air Distribution Valve As...

Страница 5: ...agm Check Valve Materials B Nitrile I EPDM N Neoprene V FKM Your Serial fill in from pump nameplate ______________________________________ __ _____ __ ___ __ __ Pump Pump Size Discharge Diaphragm Desi...

Страница 6: ...PVDF Polyvinylidene Fluoride A durable fluoroplastic with excellent chemical resistance Excellent for UV applications High tensile strength and impact resistance 250 F 121 C 0 F 18 C Santoprene Inject...

Страница 7: ...5 36 136 11 47 291 5 33 135 15 07 383 16 51 419 2 09 53 2 00 51 26 79 681 19 5 19 5 EXHAUST PORT 1 NPT AIR INLET 1 2 NPT DISCHARGE PORT 2 NPT FEMALE SUCTION PORT 2 NPT FEMALE 19 03 483 11 37 289 12 19...

Страница 8: ...ally shortened pump life The hose assemblies deliver air to the non wetted portions of the pump and care should be taken that they are neither crimped nor cut INSTALLATION PROCEDURES Position the pump...

Страница 9: ...mp at maximum cycle rate 3 Low performance A Capacity is reduced as the discharge pressure increases Performance capability varies with available inlet supply Check air pressure at the pump inlet when...

Страница 10: ...8 9 20 62 41 10 11 12 13 52 14 15 40 48 37 65 16 17 18 30 21 22 24 25 25 23 57 26 46 19 60 27 28 64 36 64 36 29 56 55 38 49 44 55 29 44 49 38 46 65 37 58 42 42 45 39 42 47 50 54 50 61 60 50 53 50 34 6...

Страница 11: ...ed with item 2 1 10 115 062 080 Bracket Mounting Left Hand 1 11 115 063 080 Bracket Mounting Right Hand 1 12 115 075 080 Bracket Mounting 1 13 132 002 360 Bumper Diaphragm 2 14 132 014 358 Bumper Air...

Страница 12: ...pylene 379 Conductive Nitrile 408 Cork and Neoprene 425 Compressed Fibre 426 Blue Gard 440 Vegetable Fibre 500 Delrin 500 502 Conductive Acetal ESD 800 503 Conductive Acetal Glass Filled 506 Delrin 15...

Страница 13: ...7 C 7 E Pilot Valve Servicing With Pilot Valve removed from pump Step 1 Remove snap ring 7 F Step 2 Remove sleeve 7 B inspect O Rings 7 C replace if required Step 3 Remove spool 7 D from sleeve 7 B i...

Страница 14: ...ration Consult the pump s published performance curve to determine this It is important to remember to inspect the sleeve and spool set routinely It should move back and forth freely This is most impo...

Страница 15: ...N809 2012 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that...

Страница 16: ...Series F Series T Series EH Series SH Series GH Series Conductive plastic pump models with integral muffler S Series PB Series Tranquilizer surge suppressors Hazardous Location Applied I M1 Ex h I Ma...