Warren rupp SANDPIPER S30 Скачать руководство пользователя страница 2

s30mdl1sm-rev1218

sandpiperpump

.

com

IMPORTANT

Read the safety warnings and instructions in this manual 

before pump installation and start-up. Failure to comply with 

the recommendations stated in this manual could damage the 

pump and void factory warranty.

When used for toxic or aggressive fluids, the pump should 

always be flushed clean prior to disassembly.

Airborne particles and loud noise hazards. Wear eye and ear 

protection.

Before maintenance or repair, shut off the compressed air line, 

bleed the pressure, and disconnect the air line from the pump. 

Be certain that approved eye protection and protective clothing 

are worn at all times. Failure to follow these recommendations 

may result in serious injury or death.

When the pump is used for materials that tend to settle out 

or solidify, the pump should be flushed after each use to 

prevent damage. In freezing temperatures the pump should be 

completely drained between uses.

Before pump operation, inspect all fasteners for loosening 

caused by gasket creep. Retighten loose fasteners to prevent 

leakage. Follow recommended torques stated in this manual.

CAUTION

WARNING

Nonmetallic pumps and plastic components are not UV 

stabilized.  Ultraviolet radiation can damage these parts and 

negatively affect material properties. Do not expose to UV light 

for extended periods of time.

Model S30 Metallic 

In the event of diaphragm rupture, pumped material may enter 

the air end of the pump, and be discharged into the atmosphere. 

If pumping a product that is hazardous or toxic, the air exhaust 

must be piped to an appropriate area for safe containment.

This pump is pressurized internally with air pressure during 

operation. Make certain that all fasteners are in good condition 

and are reinstalled properly during reassembly.

Take action to prevent static sparking. Fire or explosion can 

result, especially when handling flammable liquids. The pump, 

piping, valves, containers and other miscellaneous equipment 

must be properly grounded.

Safety Information

WARNING

Pump not designed, tested or certified to be powered by  

compressed natural gas. Powering the pump with natural  

gas will void the warranty.

Use safe practices when lifting

kg

ATEX Pumps - Conditions For Safe Use

WARNING

The use of non-OEM replacement parts will void (or negate) 

agency certifications, including CE, ATEX, CSA, 3A and EC1935 

compliance (Food Contact Materials).  Warren Rupp, Inc. cannot 

ensure nor warrant non-OEM parts to meet the stringent 

requirements of the certifying agencies. 

1. 

 

Ambient temperature range is as specifi ed in tables 1 to 3 on the next page 

(per Annex I of DEKRA 18ATEX0094X)

2. 

 

ATEX compliant pumps are suitable for use in explosive atmospheres when the equipment is properly grounded in  

   

accordance with local electrical codes

3. 

 

Non-Metallic ATEX Pumps only — See Explanation of Pump Nomenclature / ATEX Details Page

   

Conductive Polypropylene, conductive Acetal or conductive PVDF pumps are not to be installed in applications where the  

   

pumps may be subjected to oil, greases and hydraulic liquids.

4. 

 

The optionally provided solenoids shall be protected by a fuse corresponding to its rated current (max 3*Irat according  

   

to EN 60127) or by a motor protecting switch with short circuit and thermal instantaneous tripping (set to the rated  

   

current) as short circuit protection. For solenoids with a very low rated current, a fuse with the lowest current value  

   

according to the indicated standard will be suffi  cient. The fuse may be accommodated in the associated supply unit  

   

or shall be separately arranged. The rated voltage of the fuse shall be equal or greater than the stated rated voltage of the  

   

solenoid. The breaking capacity of the fuse shall be as high as or higher than the maximum expected short circuit current  

   

at the location of the installation (usually 1500 A). The maximum permissible ripple is 20% for all dc solenoids.

  

*Not applicable for all pump models — See Explanation of Pump Nomenclature / ATEX Details Page

5.  

When operating pumps equipped with non-conductive diaphragms that exceed the maximum permissible projected area,  

   

as defi ned in EN ISO 80079-36 : 2016 section 6.7.5 table 8, the following protection methods must be applied

   

- Equipment is always used to transfer electrically conductive fl uids or 

   

- Explosive environment is prevented from entering the internal portions of the pump, i.e. dry running.

6.  

Pumps provided with the pulse output kit and used in the potentially explosive atmosphere caused by the presence of  

   

the combustible dust shall be installed in such a way that the pulse output kit is protected against impact

  

*Not applicable for all pump models — See Explanation of Pump Nomenclature / ATEX Details Page

UNIVERSAL ALL AODD

Содержание SANDPIPER S30

Страница 1: ...ield Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM Copyright 2017 Warren Rupp Inc All rights reserved OPTIMIZED PERFORMANCE Certified Quality ISO 9001 Certified ISO 14001 Ce...

Страница 2: ...use of non OEM replacement parts will void or negate agency certifications including CE ATEX CSA 3A and EC1935 compliance Food Contact Materials Warren Rupp Inc cannot ensure nor warrant non OEM parts...

Страница 3: ...0 C to 50 C 20 C to 100 C T5 T100 X Ambient Temperature Range C Process Temperature Range C 20 C to 60 C 20 C to 150 C 1 Per CSA standards ANSI LC6 2018 US Canadian Technical Letter R14 G Series Natur...

Страница 4: ...posite Repair Parts Drawing Composite Repair Parts List Material Codes SECTION 4 AIR END 11 Air Distribution Valve Assembly Air Valve with Stroke Indicator Assembly Pilot Valve Assembly Intermediate A...

Страница 5: ...Gb II 2 D Ex h mb tb IIIC T100 C Db A H S A C Y 0 6 A1 A2 A3 A4 S05 M ATEX Details Wetted Material Options Non Wetted Material Options Pump Options Kit Options II 1 G Ex h IIC T5 225 C T2 Ga II 1D Ex...

Страница 6: ...82 C 32 F 0 C PVDF Polyvinylidene Fluoride A durable fluoroplastic with excellent chemical resistance Excellent for UV applications High tensile strength and impact resistance 250 F 121 C 0 F 18 C Sa...

Страница 7: ...761 3 74 95 11 76 299 3 74 95 8 84 225 15 75 400 16 72 425 DISCHARGE PORT 3 NPT 3 BSPT SUCTION PORT 3 NPT 3 BSPT METALLIC MUFFLER DIMENSION 12 00 305 6 00 152 4 91 125 10 13 257 6 84 AIR INLET 3 4 NP...

Страница 8: ...E PORT 3 RAISED FACE ANSI STYLE 150 LB FLANGE OR 80 DIN 10 BAR FLANGE METALLIC MUFFLER DIMENSION SUCTION PORT 3 RAISED FACE ANSI STYLE 150 LB FLANGE OR 80 DIN 10 BAR FLANGE 4 91 125 6 84 10 13 257 12...

Страница 9: ...e check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically p...

Страница 10: ...causing the pump to cycle erratically or stop operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off...

Страница 11: ...oint of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is desig...

Страница 12: ...059 XXX CA 14 196 164 XXX 15 196 165 XXX 16 286 098 XXX 17 286 098 604 18 360 093 360 19 360 114 360 20 360 104 379 21 360 105 360 22 518 143 XXX 23 518 144 XXX 24 545 007 XXX 25 545 008 XXX 26 560 00...

Страница 13: ...er 1 031 147 000 Air Valve Assembly stroke Indicator w no muffler 1 2 050 014 354 Ball Check Santoprene 4 050 014 351 Ball Check Food Grade Santoprene 4 050 014 360 Ball Check Buna 4 050 014 360W Ball...

Страница 14: ...GREEN 366 Food Grade Nitrile 368 Food Grade EPDM 371 Philthane Tuftane 374 Carboxylated Nitrile 375 Fluorinated Nitrile 378 High Density Polypropylene 379 Conductive Nitrile 408 Cork and Neoprene 425...

Страница 15: ...115 Hex Head Capscrew 1 4 20 x 75 8 1 J 706 026 115 Machine Screw 4 IMPORTANT Read these instructions completely before installation and start up It is the responsibility of the purchaser to retain t...

Страница 16: ...C 132 029 357 Bumper 2 1 D 560 020 360 O Ring 10 1 E 165 127 110 Cap End 2 1 F 170 032 115 Hex Head Capscrew 1 4 20 x 75 8 1 A Note Cannot be used with Integral Muffler option 0 IMPORTANT Read these i...

Страница 17: ...9 360 O Ring 2 For Pumps with PTFE Coated Hardware 1 031 146 002 Air Valve Assembly 1 1 J 710 015 308 Screw Self Tapping 4 includes all other items on 031 146 000 above For Pumps with Piped Exhaust 1...

Страница 18: ...mber Description Qty 4 095 110 558 Pilot Valve Assembly 1 4 A 095 095 558 Valve Body 1 includes all other items used on 095 110 000 For Pumps with Stainless Steel Center Section Item Part Number Descr...

Страница 19: ...9 from center of intermediate pilot valve cavity Step 2 Remove Ring Retaining 30 discard Step 3 Remove bushing plunger 7 inspect for wear and replace if necessary with genuine parts Step 4 Remove O Ri...

Страница 20: ...ump com 20 Model S30 Metallic Diaphragm Service Drawing Non Overlay Diaphragm Service Drawing with Overlay 16 17 28 9 14 24 24 31 25 15 13 6 27 16 28 9 14 24 24 31 25 15 13 6 27 16 17 28 9 14 24 24 31...

Страница 21: ...thoverlays nolubricationisrequired Step 4 Push the threaded outer diaphragm plate through the center hole of the diaphragm Note Most diaphragms are installed with the natural bulge out towards the flu...

Страница 22: ...Solenoid Coil 120VAC 60 Hz 1 219 009 002 Solenoid Coil 240VAC 60 Hz 1 219 009 003 Solenoid Coil 12VDC 1 219 009 004 Solenoid Coil 24VDC 1 219 009 005 Solenoid Coil 110VAC 50 Hz 1 219 009 006 Solenoid...

Страница 23: ...N809 2012 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that...

Страница 24: ...es MSA Series U Series F Series T Series Conductive plastic pump models with integral muffler S Series PB Series Tranquilizer surge suppressors Hazardous Location Applied I M1 Ex h I Ma II 1 G Ex h II...

Отзывы: