Warren rupp Sandpiper S1F Скачать руководство пользователя страница 11

s1fmdl1sm-rev1218

sandpiperpump

.

com

Model S1F Metallic • 

11

Troubleshooting Guide

For additional troubleshooting tips contact After Sales Support at [email protected] or 419-524-8388

Symptom:

Potential Cause(s):

Recommendation(s):

Pump Cycles Once

Deadhead (system pressure meets or exceeds air 

supply pressure).

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. 

 

(Does not apply to high pressure 2:1 units).

Air valve or intermediate gaskets installed incorrectly. Install gaskets with holes properly aligned.
Bent or missing actuator plunger.

Remove pilot valve and inspect actuator plungers.

Pump Will Not Operate 

/ Cycle

Pump is over lubricated.

Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.

Lack of air (line size, PSI, CFM).

Check the air line size and length, compressor capacity (HP vs. CFM required).

Check air distribution system.

Disassemble and inspect main air distribution valve, pilot valve and pilot valve actuators. 

Discharge line is blocked or clogged manifolds.

Check for inadvertently closed discharge line valves. Clean discharge manifolds/piping.

Deadhead (system pressure meets or exceeds air 

supply pressure).

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. 

 

(Does not apply to high pressure 2:1 units).

Blocked air exhaust muffler.

Remove muffler screen, clean or de-ice, and re-install. 

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. 

Pump chamber is blocked.

Disassemble and inspect wetted chambers. Remove or flush any obstructions. 

Pump Cycles and Will 

Not Prime or No Flow

Cavitation on suction side.

Check suction condition (move pump closer to product).

Check valve obstructed. Valve ball(s) not seating 

properly or sticking.

Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket.  

Clean out around valve ball cage and valve seat area. Replace valve ball or valve seat if damaged. 

Use heavier valve ball material.

Valve ball(s) missing (pushed into chamber or 

manifold).

Worn valve ball or valve seat. Worn fingers in valve ball cage (replace part). Check Chemical 

 

Resistance Guide for compatibility.

Valve ball(s) / seat(s) damaged or attacked by product. Check Chemical Resistance Guide for compatibility.
Check valve and/or seat is worn or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if necessary. 

Suction line is blocked.

Remove or flush obstruction. Check and clear all suction screens or strainers.

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime the pump in most cases.

Suction side air leakage or air in product.

Visually inspect all suction-side gaskets and pipe connections.

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. 

Pump Cycles Running 

 

Sluggish / Stalling,

 

Flow Unsatisfactory

Over lubrication.

Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.

Icing.

Remove muffler screen, de-ice, and re-install. Install a point of use air drier. 

Clogged manifolds.

Clean manifolds to allow proper air flow.

Deadhead (system pressure meets or exceeds air 

supply pressure).

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. 

 

(Does not apply to high pressure 2:1 units).

Cavitation on suction side.

Check suction (move pump closer to product).

Lack of air (line size, PSI, CFM).

Check the air line size, length, compressor capacity.

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime the pump in most cases.

Air supply pressure or volume exceeds system hd.

Decrease inlet air (press. and vol.) to the pump. Pump is cavitating the fluid by fast cycling. 

Undersized suction line.

Meet or exceed pump connections. 

Restrictive or undersized air line.

Install a larger air line and connection. 

Suction side air leakage or air in product.

Visually inspect all suction-side gaskets and pipe connections.

Suction line is blocked.

Remove or flush obstruction. Check and clear all suction screens or strainers.

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. 

Check valve obstructed.

Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket. 

Check valve and/or seat is worn or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if necessary.

Entrained air or vapor lock in chamber(s).

Purge chambers through tapped chamber vent plugs. Purging the chambers of air can be dangerous. 

Product Leaking 

Through Exhaust

Diaphragm failure, or diaphragm plates loose.

Replace diaphragms, check for damage and ensure diaphragm plates are tight.

Diaphragm stretched around center hole or bolt holes. Check for excessive inlet pressure or air pressure. Consult Chemical Resistance Chart for compatibility 

with products, cleaners, temperature limitations and lubrication.

Premature Diaphragm 

Failure

Cavitation.

Enlarge pipe diameter on suction side of pump.

Excessive flooded suction pressure.

Move pump closer to product. Raise pump/place pump on top of tank to reduce inlet pressure. 

Install Back pressure device (Tech bulletin 41r). Add accumulation tank or pulsation dampener.

Misapplication (chemical/physical incompatibility).

Consult Chemical Resistance Chart for compatibility with products, cleaners, temperature limitations 

and lubrication.

Incorrect diaphragm plates or plates on backwards, 

installed incorrectly or worn.

Check Operating Manual to check for correct part and installation. Ensure outer plates have not been 

worn to a sharp edge.

Unbalanced Cycling 

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime the pump in most cases.

Undersized suction line.

Meet or exceed pump connections.

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.

Suction side air leakage or air in product.

Visually inspect all suction-side gaskets and pipe connections.

Check valve obstructed.

Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket. 

Check valve and/or seat is worn or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if necessary. 

Entrained air or vapor lock in chamber(s).

Purge chambers through tapped chamber vent plugs. 

Recommended Installation Guide

2: INST

AL

 & OP

Содержание Sandpiper S1F

Страница 1: ...93 99 89 7 44 188 98 81 76 4 19 106 43 5 31 135 6 73 171 07 3 54 89 81 4X 38 9 53 MOUNTING HOLES BOTTOM VIEW 12 03 305 56 41 10 32 1 22 30 96 13 0 18 SUCTION PORT 1 NPT 5 00 127 00 9 09 230 80 1 63 41...

Страница 2: ...use of non OEM replacement parts will void or negate agency certifications including CE ATEX CSA 3A and EC1935 compliance Food Contact Materials Warren Rupp Inc cannot ensure nor warrant non OEM parts...

Страница 3: ...0 C to 50 C 20 C to 100 C T5 T100 X Ambient Temperature Range C Process Temperature Range C 20 C to 60 C 20 C to 150 C 1 Per CSA standards ANSI LC6 2018 US Canadian Technical Letter R14 G Series Natur...

Страница 4: ...posite Repair Parts Drawing Composite Repair Parts List Material Codes SECTION 4 AIR END 11 Air Distribution Valve Assembly Air Valve with Stroke Indicator Assembly Pilot Valve Assembly Intermediate A...

Страница 5: ...Ex h IIC T5 225 C T2 Ga II 1D Ex h IIIC T100 C T200 C Da I M1 Ex h I Ma H S C 6 00 II 2 G Ex h IIC T5 225 C T2 Gb II 2 D Ex h IIIC T100 C T200 C Db A H S A C Y 0 6 00 II 2 G Ex h ia IIC T5 Gb II 2 D E...

Страница 6: ...chlorinated aromatic hydrocarbons 200 F 93 C 10 F 23 C Nitrile General purpose oil resistant Shows good solvent oil water and hydraulic fluid resistance Should not be used with highly polar solvents...

Страница 7: ...41 10 32 1 22 30 96 5 13 130 18 12 88 327 09 SUCTION PORT 1 NPT 1 NPT EXHAUST PORT 5 00 127 00 8 16 207 19 4X R 16 3 97 6 75 171 45 3 87 98 35 9 09 230 80 1 63 41 28 5 00 6 39 162 31 AIR INLET 1 2 NP...

Страница 8: ...ical dimensions are needed Dimensional Drawings 10 25 260 35 5 13 130 18 13 3 18 2 00 50 80 2 00 50 80 4 18 106 29 8 37 212 71 16 04 407 30 1 NPT EXHAUST PORT 4 64 117 73 3 87 98 17 3 93 99 89 7 44 18...

Страница 9: ...e check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically p...

Страница 10: ...causing the pump to cycle erratically or stop operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off...

Страница 11: ...oint of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is desig...

Страница 12: ...Gaskets Retaining Rings Air Valve Sleeve and Spool Set and Pilot Valve Assembly 476 194 354 Wet End Kit Santoprene Diaphragms Balls and Polyethylene Seats 476 194 360 Wet End Kit Nitrile Diaphragms B...

Страница 13: ...Tapered 1 518 175 156W Welded Raised Face 150 1 ANSI Flanged Manifold 1 518 175 110 Manifold Suction 1 518 175 110E Manifold Suction 1 BSP Tapered 1 518 175 110W Welded Raised Face 150 1 ANSI Flanged...

Страница 14: ...Food Grade Nitrile 368 Food Grade EPDM 371 Philthane Tuftane 374 Carboxylated Nitrile 375 Fluorinated Nitrile 378 High Density Polypropylene 379 Conductive Nitrile 408 Cork and Neoprene 425 Compresse...

Страница 15: ...4 Note Pumps equipped with these Valve Assemblies are not ATEX compliant Air Distribution Valve Servicing See repair parts drawing remove screws Step 1 Remove hex cap screws 1 F Step 2 Remove end cap...

Страница 16: ...020 360 O Ring 10 1 E 165 127 157 Cap End 2 1 F 170 032 330 Hex Head Capscrew 1 4 20 x 75 8 Air Valve Assembly Parts List 1 031 183 001 Air Valve Assembly 1 Consists of all components above except 1 F...

Страница 17: ...alve Body 1 1 B 031 139 000 Sleeve and Spool Set 1 1 C 132 029 552 Bumper 2 1 D 560 020 360 O Ring 10 1 E 165 127 110 Cap End 2 1 F 170 032 115 Capscrew 8 Note cannot be used with integral muffler Opt...

Страница 18: ...9 360 O Ring 2 For Pumps with PTFE Coated Hardware 1 031 146 002 Air Valve Assembly 1 1 J 710 015 308 Screw Self Tapping 4 includes all other items on 031 146 000 above For Pumps with Piped Exhaust 1...

Страница 19: ...e O Rings 4 C and 4 E Reassemble in reverse order Pilot Valve Assembly Parts List Item Part Number Description Qty 4 095 110 000 Pilot Valve Assembly 1 4 A 095 095 157 Valve Body 1 4 B 755 052 000 Sle...

Страница 20: ...ger 2 21 560 001 360 O Ring 2 25 620 022 115 Plunger Actuator 2 26 675 042 115 Ring Retaining 2 28 720 010 375 Seal Diaphragm Rod 2 Intermediate Assembly Drawing Step 1 Remove plunger actuator 25 from...

Страница 21: ...oprene and Elastomer diaphragms Diaphragm Service Drawing Non Overlay Diaphragm Service Drawing with Overlay One Piece Bonded Diaphragm Service Drawing 14 Available For Field Conversion From Overlay T...

Страница 22: ...y together Torque values are called out on the exploded view Repeat procedure for second side assembly Allow a minimum of 15 minutes to elapse after torquing then re torque the assembly to compensate...

Страница 23: ...of lowest current value according to the indicated IEC standard will be sufficient The fuse may be accommodated in the associated supply unit or shall be separately arranged The rated voltage to the...

Страница 24: ...N809 2012 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that...

Страница 25: ...Series MSA Series U Series F Series T Series Conductive plastic pump models with integral muffler S Series PB Series Tranquilizer surge suppressors Hazardous Location Applied I M1 Ex h I Ma II 1 G Ex...

Отзывы: