Warren rupp Sandpiper HDF3-M Скачать руководство пользователя страница 10

hdf3mdl2sm-rev0316  

Model HDF3-M & HDF4-M  Page 8

REASSEMBLY

 

All procedures for reassembling the pump are the reverse of the previous 

 

instructions with further instructions as shown:

1.  The diaphragm assemblies are to be installed with the natural bulge outward 
or toward the head of the center screw. Make sure both plates are installed with 
outer radii against the diaphragm.  After all components are in position in a vise and 
hand tight, set a torque wrench for 480 inch pounds (40 ft. pounds) (54.23 Newton  
meters) or, 600 inch pounds (50 ft. pounds) (67.79 Newton meters) for Santoprene, 
using a (3/8") allen head socket. After each diaphragm sub assembly has been  
completed, thread one assembly into the shaft (held near the middle in a vise having 

soft jaws to protect the finish) making sure the stainless steel washer is in place on 

the capscrew. 
 

Make sure 1/4"-20 mounting screw has been removed and that the bumper (Item 

#19 on drawing) is in place in the shaft.
 

Install this sub assembly into the pump and secure by placing the outer chamber 

housing and capscrews on the end with the diaphragm. This will hold the assembly 
in place while the opposite side is installed. Make sure the last diaphragm assembly 
is torqued to 30 ft. lbs. (40.67 Newton meters) before placing the outer diaphragm 

over the capscrews. If the holes in the diaphragm flange do not line up with the holes 

in the chamber flange, turn the diaphragm assembly in the direction of tightening 

to align the holes so that the capscrews can be inserted. This final torquing of the 

last diaphragm assembly will lock the two diaphragm assemblies together. Place  
remaining outer chamber on the open end and tighten down the securing nuts 

 

gradually and evenly on both sides. 
 

Caution should be used while reassembling Flap valves. The valves are designed 

for some preload over the retainer hinge pad. This is done to insure proper face contact 
with the seat. After all  parts are in place, tighten the lock nuts down on the assembly 
to the point where visual inspection shows that seat and valve face mate without gap. 
This is important for dry prime. However, after priming action has started, valves will 
function due to differential pressure without concern or trouble.

PILOT VALVE

 

The pilot valve assembly is accessed by removing the main air distribution valve 

body from the pump and lifting the pilot valve body out of the intermediate housing.
 

Most problems with the pilot valve can be corrected by replacing the o-rings. 

Always grease the spool prior to inserting it into the sleeve. If the sleeve is removed 
from the body, reinsertion must be at the chamfered side. Grease the o-rings to slide 
the sleeve into the valve body. Securely insert the retaining ring around the sleeve. 
When reinserting the pilot valve, push both plungers (located inside the intermediate 
bracket) out of the path of the pilot valve spool ends to avoid damage.

PILOT VALVE ACTUATOR

 

Bushings for the pilot valve actuators are threaded into the intermediate bracket 

from the outside. The plunger may be removed for inspection or replacement. First 
remove the air distribution valve body and the pilot valve body from the pump. The 
plungers can be located by looking into the intermediate. It may be necessary to 

use a fine piece of wire to pull them out. The bushing can be turned out through the 

 

inner chamber by removing the outer chamber assembly. Replace the bushings if pins
have bent.

Tel:  866-777-6060 
Fax: 866-777-6383

Springer Pumps, LLC 

Website: www.springerpumps.com 

Int'l: +001 267 404 2910

Содержание Sandpiper HDF3-M

Страница 1: ...Instructions Troubleshooting 9 Warranty 9 Material Codes 10 Composite Repair Parts List 11 12 Composite Repair Drawing 13 CE Declaration of Conformity Machinery 14 CE Declaration fo Conformity ATEX 1...

Страница 2: ...When the pump is used for materials that tend to settle out or solidify the pump should be flushed after each use to prevent damage In freezing temperatures the pump should be completely drained betw...

Страница 3: ...ompressed air II 2GD T5 See pages 17 18 for ATEX ratings U S Gallons per minute 10 0 0 20 30 40 50 60 70 80 90 100 20 40 60 80 100 120 140 160 180 200 220 240 260 20 34 60 PSI 40 PSI 40 68 60 101 9 80...

Страница 4: ...res For specific applications always consult Chemical Resistance Chart Technical Bulletin Nitrile General purpose oil resistant Shows good solvent oil water and hydraulic fluid resistance Should not b...

Страница 5: ...ction Discharge Ports Four 4 3 4 dia thru holes equally spaced on a 6 diameter bolt circle 4 Eight 8 5 8 11 unc tapped holes equally spaced on a 7 1 2 diameter bolt circle Dimension A 30 1 4 768 31 78...

Страница 6: ...ragm plate coming in contact with the end of the pilot spool This pushes it into position for shifting of the air distribution valve The chambers are manifolded together with a suction and discharge f...

Страница 7: ...The air exhaust should be piped to an area for safe disposition of the product being pumped in the event of a diaphragm failure CAUTION Available from Distributor Available from Warren Rupp Tel 866 7...

Страница 8: ...removing these four hex head capscrews With the valve body assembly off the pump access to the sleeve and spool set is made by removing four hex head capscrews each end on the end caps of the valve b...

Страница 9: ...e valve and seat are connected as an as sembly When the bottom discharge elbows are removed the valve and seat stay with the outer chamber Visual inspection and cleaning is pos sible If parts are to b...

Страница 10: ...hten down the securing nuts gradually and evenly on both sides Caution should be used while reassembling Flap valves The valves are designed for some preload over the retainer hinge pad This is done t...

Страница 11: ...r strainer plugged F Diaphragm ruptured PROBLEM Pump will not cycle Note Always disconnect air supply to relieve air pressure before disassembling any portion of pump POSSIBLE CAUSES A Discharge hose...

Страница 12: ...Food Grade EPDM Color GRAY 370 Butyl Rubber Color Coded BROWN 371 Philthane Tuftane 374 Carboxylated Nitrile 375 Fluorinated Nitrile 378 High Density Polypropylene 379 Conductive Nitrile Color Coded R...

Страница 13: ...Body Valve 1 18 196 100 015 Chamber Inner 2 19 560 022 360 O Ring 2 20 170 045 330 Capscrew Hex Head 4 21 530 036 000 Muffler Exhaust 1 22 685 041 120 Rod Diaphragm 1 23 115 068 080 Bracket Support 1...

Страница 14: ...sed with Santoprene 4 62 170 082 330 Capscrew Hex Head 14 63 570 010 360 Pad Wear 2 570 010 364 Pad Wear Use with Santoprene 2 570 010 365 Pad Wear 2 Not Shown 031 021 010 Valve Body Assembly 1 consis...

Страница 15: ...4 M Page 13 2010 Warren Rupp Inc All rights reserved SANDPIPER are registered tradenames of Warren Rupp Inc USE WITH HDF4 M ONLY Tel 866 777 6060 Fax 866 777 6383 Springer Pumps LLC Website www spring...

Страница 16: ...nnex VIII This product has used Harmonized Standard EN809 1998 A1 2009 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc...

Страница 17: ...Pumps and Surge Suppressors Technical File No 203104000 1410 MER AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09ATEX0071 X DEKRA Certification B V 0344 Meande...

Отзывы: