Models HDB1½-A, HDB40-A  Page 4 

hdb15dl6sm-REV0208

assembly in place while the opposite side is installed. Make sure the last diaphragm 
assembly is torqued to 30 ft. lbs. (40.67 Newton meters). This final torquing will lock 
the diaphragm assemblies together. Place remaining outer chamber on open end and 
secure. Snug flange bolts of chamber to port manifold to square the flanges before 
the final tightening of the V-Band clamps. Tighten flange bolts securely after tightening 
V-Band clamp.  

IMPORTANT: Do not tighten the V-Band clamp without loosen-

ing manifold flange bolts at outer chamber ports. The chamber flange may be 
broken this way.

A Note about Air Valve Lubrication

 

The SANDPIPER pump’s pilot valve and main air valve assemblies are designed 

to operate WITHOUT lubrication. This is the preferred mode of operation. There may 
be instances of personal preference, or poor quality air supplies when lubrication of 
the compressed air supply is required. The pump air system will operate with properly 
lubricated compressed air supplies. Proper lubrication of the compressed air supply 
would entail the use of an air line lubricator (available from Warren Rupp) set to deliver 
one drop of 10 wt., non-detergent oil for every 20 SCFM of air the pump consumed at 
its point of operation. Consult the pump’s published Performance Curve to determine 
this.
 

It is important to remember to inspect the sleeve and spool set routinely. It should 

move back and forth freely. This is most important when the air supply is lubricated. 
If a lubricator is used, oil accumulation will, over time, collect any debris from the 
compressed air. This can prevent the pump from operating properly.
 

Water  in  the  compressed  air  supply  can  create  problems  such  as  icing  or 

 

freezing of the exhaust air causing the pump to cycle erratically, or stop operating. This 
can be addressed by using a point of use air dryer to supplement a plant’s air drying 
equipment. This device will remove excess water from the compressed air supply and 
alleviate the icing or freezing problem.

ESADS: Externally Serviceable Air Distribution System

 

Please refer to the exploded view drawing and parts list in the Service Manual 

supplied with your pump. If you need replacement or additional copies, contact your 
local Warren Rupp Distributor, or the Warren Rupp factory Literature Department at 
the number shown below. To receive the correct manual, you must specify the MODEL 
and TYPE information found on the name plate of the pump.

Models with 1" suction/discharge or larger, and METAL center sections:

 

The main air valve sleeve and spool set is located in the valve body mounted on 

the pump with four hex head capscrews. The valve body assembly is removed from 
the pump by removing these four hex head capscrews.
 

With the valve body assembly off the pump, access to the sleeve and spool set 

is made by removing four hex head capscrews (each end) on the end caps of the 
valve body assembly. With the end caps removed, slide the spool back and forth in 
the sleeve. The spool is closely sized to the sleeve and must move freely to allow for 
proper pump operation. An accumulation of oil, dirt or other contaminants from the 
pump’s air supply, or from a failed diaphragm, may prevent the spool from moving freely. 
This can cause the spool to stick in a position that prevents the pump from operating. 
If this is the case, the sleeve and spool set should be removed from the valve body 
for cleaning and further inspection.
 

Remove the spool from the sleeve. Using an arbor press or bench vise (with an 

improvised mandrel), press the sleeve from the valve body. Take care not to damage 
the sleeve. At this point, inspect the o-rings on the sleeve for nicks, tears or abrasions. 
Damage of this sort could happen during assembly or servicing. A sheared or cut 

 

o-ring can allow the pump’s compressed air supply to leak or bypass within the air 
valve assembly, causing the pump to leak compressed air from the pump air exhaust 
or not cycle properly. This is most noticeable at pump dead head or high discharge 
pressure conditions. Replace any of these o-rings as required or set up a routine, 
preventive maintenance schedule to do so on a regular basis. This practice should 
include cleaning the spool and sleeve components with a safety solvent or equivalent, 
inspecting for signs of wear or damage, and replacing worn components.

IMPORTANT

Do not tighten the V-Band clamp without 
loosening maniford flange bolts at outer 
chamber ports.  The chamber flange 
may be broken this way.  

Содержание HDB1

Страница 1: ... 3 Air Exhaust 3 Between Uses 3 Check Valve Servicing 3 Diaphragm Servicing 3 Air Valve Lubrication 3 ESADS Plus Externally Serviceable Air Distribution System 5 Pilot Valve 5 Pilot Valve Actuator 5 Service Instructions Troubleshooting 6 Warranty 6 Recommended Accessories 6 Important Safety Information 7 Recycling 7 Grounding The Pump 8 Material Codes 9 Declaration of Conformity 10 Composite Repai...

Страница 2: ......

Страница 3: ... spool is moved by an internal pilot valve which alternately pressurizes one side of the air distribution valve spool while exhausting the other side The pilot valve is shifted at each end of the diaphragm stroke by the diaphragm plate coming in contact with the end of the pilot spool This pushes it into position for shifting of the air distribution valve The chambers are manifolded together with ...

Страница 4: ...pressor Filter Regulator Air Dryer Available from Warren Rupp 1 3 INSTALLATION GUIDE Top Discharge Ball or Flap Valve Unit Surge Suppressor 2 CAUTION The air exhaust should be piped to an area for safe disposition of the product being pumped in the event of a diaphragm failure ...

Страница 5: ... ball valves is usually indicated by poor priming unstable cycling reduced performance or pump cycles but will not pump Inspection and service of check valves requires the removal of six bolts which provide access to all four ball valves and both suction and discharge valve seats New ball check valves are 21 4 5 715 cm diameter and will require replacement when worn to approximately 2 5 08 cm diam...

Страница 6: ...st in the Service Manual supplied with your pump If you need replacement or additional copies contact your local Warren Rupp Distributor or the Warren Rupp factory Literature Department at the number shown below To receive the correct manual you must specify the MODEL and TYPE information found on the name plate of the pump Models with 1 suction discharge or larger and METAL center sections The ma...

Страница 7: ...ody out of the intermediate housing Most problems with the pilot valve can be corrected by replacing the o rings Always grease the spool prior to inserting it into the sleeve If the sleeve is removed from the body reinsertion must be at the chamfered side Grease the o rings to slide the sleeve into the valve body Securely insert the retaining ring around the sleeve When reinserting the pilot valve...

Страница 8: ...case D Blockage in diaphragm chamber preventing movement Shut off air supply and reopen after pressure is relieved E Muffler clogged PROBLEM Uneven discharge flow Indicates one chamber not operating properly POSSIBLE CAUSES A Check valve not sealing properly in one chamber B Diaphragm failure in one chamber C Air leak at suction manifold joint or elbow flange one side D Muffler clogged For additio...

Страница 9: ...charged into the atmosphere If pumping a product which is hazardous or toxic the air exhaust must be piped to an appropriate area for safe disposition IMPORTANT SAFETY INFORMATION Take action to prevent static sparking Fire or explosion can result especially when handling flammable liquids The pump piping valves containers or other miscellaneous equipment must be grounded See page 32 WARNING IMPOR...

Страница 10: ... is fastened to the pump hardware The clamp end is installed to a true earth ground To reduce the risk of static electrical sparking this pump must be grounded Check the local electrical code for detailed grounding instruction and the type of equipment required or in the absence of local codes an industry or nationally recognized code having juristiction over specific installations This 8 foot lon...

Страница 11: ...hdb15dl6sm REV0208 Models HDB1 A HDB40 A Page 9 ...

Страница 12: ...inment Duty Gas UL High Pressure W Submersible and Tranquilizers comply with the European Community Directive 98 37 EC Safety of Machinery This product has used EN 809 Pumps and Pump Units for Liquids Common Safety Requirements harmonized standard to verify conformance Signature of authorized person Date of issue Printed name of authorized person Title Declaration of Conformity CE David Roseberry ...

Страница 13: ...2 097 110 Plate Assembly Outer 2 612 097 112 Plate Assembly Outer 2 21 286 005 365 Diaphragm 2 286 005 354 Diaphragm 2 286 005 364 Diaphragm 2 286 005 363 Diaphragm 2 286 005 360 Diaphragm 2 22 196 007 156 Chamber Outer 2 196 007 010 Chamber Outer 2 196 007 110 Chamber Outer 2 196 007 112 Chamber Outer 2 23 560 022 360 O Ring 2 26 115 046 080 Bracket Foot Side Ported Only 2 115 057 080 Bracket Foo...

Страница 14: ...900 005 330 Washer Lock 6 31 12 900 006 330 Washer Lock 4 31 13 170 040 330 Capscrew Hex Head 6 33 170 045 330 Capscrew Hex Head 4 34 095 073 000 Pilot Valve Body Assembly1 2 1 095 115 000 Pilot Valve Body Assembly CI Only 1 34 A 095 070 551 Pilot Valve Body 1 34 B 755 025 000 Sleeve w O Ring 1 34 C 560 033 360 O Ring Sleeve 4 34 D 775 026 000 Spool w O Ring 1 34 E 560 023 360 O Ring Spool 2 34 F ...

Страница 15: ...M TOTAL NO PART NUMBER DESCRIPTION RQD 49 545 004 330 Nut Hex Bottom Ported Only 2 50 900 004 330 Washer Lock Bottom Ported Only 2 51 570 009 360 Wear Pad 2 570 009 363 Wear Pad 2 570 009 364 Wear Pad 2 570 009 365 Wear Pad 2 Use w Santoprene Fitted Pumps 52 312 020 156 Elbow Bottom Ported Only 1 312 020 110 Elbow Bottom Ported Only 1 53 544 001 330 Nut Flange Bottom Ported Only 4 ...

Страница 16: ...nc All rights reserved Warren Rupp and SANDPIPER are registered tradenames of Warren Rupp Inc Printed in U S A B These Items Available in Kit Form Only Order Rubber Foot Kit P N 475 101 000 A These Items Available in Kit Form Only Order Angle Valve Kit P N 475 102 000 ...

Отзывы: