![WARPP INTIG 250 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/warpp/intig-250/intig-250_instruction-manual_3455140010.webp)
CAUTION:
Before Maintenance and checking, power must be turned off, and before
Opening the housing, make sure the power plug is pulled off.
1. Remove dust by dry and clean compressed air regularly, if welding machine is operating in
environment with smokes and pollution air, the machine need remove dust
everyday.
2. Pressure of compressed air must be inside the reasonable arrangement in order to prevent
damaging to small components of inter-machine.
3. Check inter circuit of welding machine regularly and make sure the cable
Circuit is connected correctly and connectors are connected tightly (especially insert connector
and components). If scale and loose are found, please give a good polish to them, then
connect them again tightly.
4. Avoid water and steam enter into inter-machine, if them enter into machine, please dry inter-
machine then check insulation of machine.
5. If welding machine is not operated for long time, it must be put into packing box and store in dry
environment.
BEFORE CHECKING
Blind experiment and careless repair may lead to more problem of the machine that will make
formal check and repair more difficult. When the machine is electrified, the naked parts contain
life-threatening voltage. Any direct and indirect touch will cause electric shock, and severe
electric shock will lead to death.
MAINTENANCE
WARNING
Содержание INTIG 250
Страница 6: ...IN TIG 250 ...