![Warner Electric MCS-836 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/warner-electric/mcs-836/mcs-836_service-and-installation-instructions_873120002.webp)
2
Warner Electric • 800-825-9050
P-241-78
Specifications
Mounting:
Plug-in, mates directly with
connector on photoelectric
amplifier board.
Timing Controls:
Potentiometers, adjustable
Weight:
1 oz.
Ambient Temperature:
0 - 125ºF. (-18 –– +52°C)
Light or Dark Operation:
Selectable
Timing Ranges:
MCS-836:
0.4 to 15 seconds
MCS-836-1:
1 to 30 seconds
MCS-836-2:
0.02 to 0.5 seconds
Minimum Input Pulse:
20 milliseconds for delay
pull, delay drop, and dual
delay. 50 microseconds for
one-shot and delayed
one-shot
Minimum Reset Time:
1 millisecond for all
functions
Electrical: Pin No.
Function
+
+24 VDC Input
-
Return (ground)
A
Timer Input
B
Timer Output
Part Numbers:
MCS-836:
7400-448-024
MCS-836-1:
7400-448-029
MCS-836-2:
7400-448-030
Operations
The timer module is an optional plug-in device
which modifies the basic on-off photoelectric
control operation. These functions are necessary
for special timing applications. Dark-to-Light and
Light-to-Dark transitions may be used to trigger
any function, as selected.
Delay Pull:
This function provides a delayed
response for pull-in (energize) of the output
device. The time delay is adjustable from 0.4 to
15 seconds.
2.520 MAX.
P1
P2
1.650
MAX.
.450
.300
POST INSERTION
.200 .015
+-
1
2
3
4
5
6
B
A
+
-
SWI
.156
1.600
1.912
COMPONENT SIDE
Decrease
Outline Diagram
.5625
MAX.
.093 MAX
.062 .008
.062 .015
+-
+-
MOUNTING POST
®
DIST. AUTORIZADO
MEX (55) 53 63 23 31
QRO (442) 1 95 72 60
MTY (81) 83 54 10 18
[email protected]