6
Warner Electric • 800-825-9050
P-269
Electrical Connections
All electrical current must be
off when making electrical connections to
prevent injury or death which can result from
contact with live wires.
AC Input Power Connections
❑
1. Connect Earth Ground wire to Terminal 1
and tighten securely.
❑
2. Connect the Hot side of the 120 VAC line
to Terminal 2 and tighten securely.
Note:
Customer supplied fuse is desirable.
See diagram for connection and sizing.
❑
3. Connect the neutral side of the 120 VAC
line to Terminal 3 and tighten securely.
❑
4. For power applied clutch/brake
arrangement proceed to the wiring
diagram and section below.
Normal Clutch/Brake Wiring
(Power applied clutches or brakes)
Figure 3
❑
1. Connect either the clutch or brake magnet to
Terminals 4 and 5. Tighten Terminal 4 securely.
❑
2. Connect the other magnet, either brake or
clutch to Terminals 7 and 8. Tighten Terminal 7
securely.
❑
3. Connect switching for Channel 1 to Terminals
5 and 6. Tighten both terminals securely.
❑
4. Connect switching for Channel 2 to Terminals
8 and 9. Tighten both terminals securely.
❑
5. Set DIP Switch, SW1 for proper current
setting before applying power to the control.
See INTERNAL SWITCH SETTINGS CHART for
proper DIP Switch settings
❑
6. If external potentiometers are being used,
then proceed to the external potentiometer
wiring section. If they are not used, this
completes the wiring of the control.
❑
7. Double check all connections before
applying power.
Clutch/Brake and Switch Wiring
®
DIST. AUTORIZADO
MEX (55) 53 63 23 31
QRO (442) 1 95 72 60
MTY (81) 83 54 10 18
[email protected]