6.4.3. Day
Here you can set the day of the week: 

• Monday
• Tuesday
• Wednesday
• Thursday
• Friday
• Saturday
• Sunday

Please note: You need to use the Down button
to move to the end of the list of weekdays.

6.4.4. Temperature
Scale
Here you can specify what temperature unit
should be used in the display:

• °C (Celsius, with a resolution of 0.5 degree)
• °F (Fahrenheit, with a resolution of 1 

degree)

• A scale from 1-10 (in steps of about 10°). 

Display shows
Here you can decide whether the display shall
show the time, set point and/or air temperature.

• Time (On/Off)
• Set point (On/Off) (The current temperature

that the thermostat has been set to, for 
instance in the 4-event settings.)

• Air Temp. (On/Off). The room/air 

temperature currently registered by the 
sensor.

6.4.5. Child lock 
By switching on the child lock you can lock the
menus (marked with a padlock symbol on the
display). Then it will no longer be possible to
select the sub-menus and change the settings.
You can still set a comfort temperature and the
time, though.

Please note: You can still use the Reset button
to return to factory settings, if the child lock has
been switched on.  

6.4.6. Heater 
Here you can define the type of heater that the
thermostat is attached to:

• Wire
• Ribbon
• Carbon
• Radiator
• Type A
• Type B
• Type C
• User Defined 

Please refer to Appendix for configuration table
showing combinations of heater type and
covering.

6.4.7. Covering 
Here you can enter the type of floor covering:

• Ceramic Tiles
• Stone
• Laminate
• Wood
• Carpet
• Vinyl
• Other

Please refer to Appendix for configuration table
showing combinations of heater type and
covering.

6.4.8. Sub Floor 
Here you can enter the type of sub floor:

• Concrete
• Screed
• WBP Ply
• Ins. Backer Board
• Backer Board

6.4.9. Application 
Here you can select the type of regulator
application:

• Floor Temp. Cont.: A floor sensor is used.

• Fl. Cont. 2 sensors: Both floor sensor and

limit sensor are used. A maximum
temperature limit can be set for the limit
sensor, so the thermostat will switch off if
the temperature at the place of the limit
sensor reaches the maximum temperature.
This set-up with a limit sensor can, for
instance, be used to avoid damage to some
delicate floor covering.  

• Air Temp. Control: The sensor is placed in

the thermostat.

• Air Cont. Floor limit: Apart from the sensor

inside the thermostat an extra limit sensor
is used. A maximum temperature limit can
be set for the limit sensor, so the thermostat
will switch off if the temperature at the
position of the limit sensor reaches the
maximum temperature. This set-up with an
extra limit sensor can, for instance, be used
to avoid damage to some delicate floor
covering.

• Regulator Control: No sensor is used here.

The thermostat will turn on in sequences of
20 minutes, and you can specify the length
of the sequences as a percentage of 20
minutes. If you, for example, set the
regulator to 50, the thermostat will turn on
for 10 minutes, switch off for 10 minutes,
and then turn on again for 10 minutes.

• External Control: Used in case of a set-up

with several thermostats being controlled
by an external master thermostat. Then the
thermostat will work as a slave, and you
cannot apply any settings at all since the
master thermostat controls it.

6.5.  Service
If you need tecnical help then select Service
from the main menu to see the contact
information. 

6.6. Contact Details
Select Contact Details from the main menu to
see the contact information.

Warmup plc
www.warmup.com
GB +442084536868
USA +12037910072
ES +34800099988
PT +351800812080
F +33080563990

6.7. Engineer Settings
To select Engineer settings, press the up and
down button at the same time for 5 seconds.  
Note: Changes may invalidate warranty.

6.7.1. Readout
Here you see readouts of the following current
temperatures:

• Room temp
• Floor temp
• Floor limit temp

You can also get readouts of some statistics:

• Min daily: A percentage indicating the 

minimum activated period within 24 hours
over the last 14 days. 

• Max daily: A percentage indicating the

maximum activated period within 24 hours
over the last 14 days.

• 2 Days: Indicates how many % the heater

has been turned on for the last two days.

• 30 Days: Indicates how many % the heater

has been turned on for the last 30 days.

• 360 Days: Indicates how many % the

heater has been turned on for the last 360
days.

• Min Air: Minimum room temperature within

the last 48 hours.

• Mean Air: Average room temperature

within the last 48 hours.

• Max Air: Maximum room temperature

within the last 48 hours.

• Min Floor: Minimum floor temperature

within the last 48 hours.

• Mean Floor: Average floor temperature

within the last 48 hours.

• Max Floor: Maximum floor temperature

within the last 48 hours.

• Cut out cnt: Number of relay connections

in the service life of the thermostat. This
value is never reset.

• Application: Here you can get readout for

the current application type that has been
selected in the General settings
- Floor
- Floor-2
- Air
- Air-Limit
- Reg.
- Ext.

• Software ver.: Indicates the current version

of the software.

6.7.2. Temp. Settings
Here you can specify the wanted minimum and
maximum temperatures for air, floor, or external
limit sensor.

Before you can select minimum and maximum
limits for air, floor or limit sensor, the application
for the regulator type in question must be
chosen. Please refer to section 6.4.9 about
General Settings – Application for more
details.

Please note: If you do not specify any settings
here, the factory settings will be used. 

• Air Temp. Range

-

Max Temp

-

Min Temp

• Floor Temp. Range

-

Max Temp

-

Min Temp

• Limit Sensor

-

Max Temp

-

Min Temp

6.7.3. Adaptive function
Here you can activate/deactivate (On/Off) the
adaptive function. This function is only related
to the 4-event timer and only works in
connection with going from one event to
another where the temperature is going to be

3

Air temperature

Set point

Time

Содержание WA-XSTAT-V

Страница 1: ... schedule that is suitable for most installations Unless you change these settings the thermostat will operate to this default program Working with lower temperatures during times that the room is unoccupied will lower your energy costs without reducing the comfort The thermostat has an adaptive function that automatically changes the start time of a heating period so that the desired temperature ...

Страница 2: ...can select the desired temperature for Day and Night for when you are Out and at Home and for the Weekend Day and Weekend Night Moreover you can define when you want each time period Day Night Out Home Weekend Day and Weekend Night to begin Please note You need to use the Down button to move to the end of the menu Finally you can specify temperatures and periods Day Night Out Home for each day of ...

Страница 3: ...20 minutes If you for example set the regulator to 50 the thermostat will turn on for 10 minutes switch off for 10 minutes and then turn on again for 10 minutes External Control Used in case of a set up with several thermostats being controlled by an external master thermostat Then the thermostat will work as a slave and you cannot apply any settings at all since the master thermostat controls it ...

Страница 4: ...ons is not deleted though 7 Error Messages If you get an error the LED is flashing red Internal failure Contact Warmup External failure Contact Warmup 4 Day 1 5 Event Time With floor sensor With air sensor Day 06 00 08 00 25 C 20 C Out 08 00 16 00 20 C 15 C Home 16 00 22 30 27 C 22 C Night 22 30 06 00 20 C 15 C Day 6 7 Event Time With floor sensor With air sensor Day 08 00 23 00 27 C 22 C Night 23...

Страница 5: ... las instalaciones A menos que usted cambie estos ajustes el termostato funcionará con este programa predeterminado El funcionamiento con temperaturas menores durante las horas en que la habitación no esté habitada reducirá sus costes de energía sin sacrificar su comodidad El termostato tiene una función adaptativa que cambia automáticamente la hora de activación de un período de calefacción de ma...

Страница 6: ...ra para cada día en un período de 7 días Puede seleccionar la temperatura deseada para el Día y la Noche para cuando usted esté Ausente y En casa y también para Fin de semana Día y Fin de semana Noche Además usted puede definir cuándo desea que comience cada período de tiempo Día Noche Ausente En casa Fin de semana Día y Fin de semana Noche Tome nota Es necesario que utilice el botón Abajo para ll...

Страница 7: ...a para el sensor limitador de manera que el termostato se apagará si la temperatura en la ubicación del sensor limitador alcanza el valor máximo seleccionado Esta configuración con un sensor limitador adicional se puede utilizar por ejemplo para evitar daños a algunas cubiertas de piso delicadas Control regulador Contr regulador Aquí no se utiliza ningún sensor El termostato se activará en secuenc...

Страница 8: ...te Fil Pilote Encendico Apagado 6 7 6 Reajuste Reajuste 2 Reajusta los valores definidos en Ajustes ingeniería a los valores de fábrica Reajuste 3 Igual que Reajuste 2 excepto que se borran los datos históricos Sin embargo no se borra el número de conexiones de relé 7 7 Mensajes de error Si obtiene un error el LED se iluminará intermitentemente en rojo Error interno Comuníquese con Warmup Error ex...

Страница 9: ...ist ab Fabrik mit einem für die meisten Anlagen passenden Zeitplan vorprogrammiert Falls Sie diese Einstellungen nicht ändern arbeitet der Thermostat gemäß diesen Vorgaben Niedrigere Temperaturen in Perioden in denen der Raum nicht benutzt wird bedeuten niedrigere Energiekosten ohne Verminderung des Komforts Der Thermostat verfügt über eine Adaptivfunktion die automatisch den Beginn einer Heizperi...

Страница 10: ...s Betriebs Menü auf Auto eingestellt lässt sich das 4 Phasen Programm auf automatische Regelung gemäß den individuellen Temperatur vorgaben für jeden einzelnen Tag über einen Zeitraum von 7 Tagen einstellen Die gewünschten Temperaturen für Tag und Nacht wenn Sie abwesend und wenn Sie anwesend sind für den Wochenendetag und die Wochenendenacht lassen sich einstellen Außerdem können Sie den Zeitpunk...

Страница 11: ...h zum im Thermostat eingebauten Fühler kommt ein Begrenzungsfühler zum Einsatz Mit dem Begrenzungsfühler wird eine maximale Grenztemperatur festgelegt der Thermostat schaltet ab wenn die Temperatur am Platzierungsort des Begrenzungsfühlers die maximale Tempera tur erreicht Die Anwendung mit zusätz lichem Begrenzungsfühler empfiehlt sich wenn z B eine Beschädigung von empfindlicher Bodenabdeckung v...

Страница 12: ...itte beachten Das Fil Pilote Menü ist nur in Typ WA XSTAT VB verfügbar Kommt haupt sächlich in Frankreich zur Anwendung Öko Temp Spartemperatur Frostsicherungstemp Frostsich temp Frostschutz Fil Pilote Ein Aus 6 7 6 Reset Rückstellung 2 Rückstellwerte sind unter Technische Einstellungen als Fabrikein stellungen festgelegt Rückstellung 3 Gleich wie Rückstellung 2 jedoch historische Daten werden gel...

Отзывы: