Warmup underlaminate Скачать руководство пользователя страница 4

Important!

WARNING

Once the foil heating mat has been installed avoid all traffic over the mat until the floor has been laid.

Do not install the foil heating mat until the floor is ready to be laid. If the floor is not being laid
immediately, all heating mats must be protected with two layers of cardboard or hardboard to
prevent damage.

Immediately prior to the floor being laid, check it has not been damaged in transit.

If you are in any doubt call the Warmup helpline on 

0845 345 2288

4

Please read carefully before installing your Warmup

®

underlaminate foil

heating mats.

DON’T  

leave insulating materials such as bean bags; linen or towels on the floor

surface. The maximum thermal resistance recommended between the heater 
and the room is 0.15 m2K/W (1.5 TOG).

DON’T

overlap heating mats. 

DON’T

fold or wrinkle Warmup

®

Underlaminate foil heating mats. 

DON’T

place heavy/sharp tools (or any other potentially damaging object)
on top of the heating mats.

DON’T

walk unnecessarily on the foil heating mats.

DON’T

install electrical cables or pipes under the floor with the foil heating mats.

DON’T

use cellulose insulation.

DON’T

install mats when the room temperature is below -5ºC.

DON’T

install foil heating mats anywhere except inside buildings.

DON’T

install foil mats under walls or partitions,or in areas under heavy cabinets,
closets, or fixtures (toilets, sinks, tubs, etc.).

DON’T

install foil mats within 30mm of any heat conductive building part, such as 
cold water pipes.

DON’T

install foil mats within 10mm of one another, 50mm of any wall, or 
150mm of a fireplace or hot water pipe. 

DON’T

connect any other electrical appliance on the same electric fused 

spur or RCD/SPUR unit of the heating system

DON’T 

install foil heating mats under wooden floor, if the wooden floor is thicker than

18 mm.

DON’T  

put accustic material between the foil heating mats and the wooden floor,

installing wooden type floor.

DON’T

use this heater under any floor covering other than wood or laminate 
flooring.

DON’T

place items on the floor surface which will stop the air flow or not allow heat

to rise into the room.

DON’T:

Содержание underlaminate

Страница 1: ... attempting to install your foil heater Incorrect installation could damage the heater and will invalidate your warranty by filling in your Guarantee information online at warmup com by filling in your Guarantee information online at warmup co uk Complete and submit the warranty form online at www warmup co uk ...

Страница 2: ... connecting junction for the electrical supply cables of the heating mats Control thermostat allows you to control the temperature of the room Residual Current Device Consult your electrician regarding the applicable RCD Hard insulation materials used as heat insulator under the foil heating mats in installations with concrete subfloors to provide more efficient heating The material comes in plate...

Страница 3: ...eating mats and their values Contents NOTICE This product MUST be used with a dedicated RCD residual current device If these instructions are followed you should have no problems However if you do require help at any stage please call our 24hr helpline Warmup Technical Helpline 0845 345 2288 You can also find a copy of this manual wiring instructions a list of frequently asked questions and more h...

Страница 4: ...ts DON T walk unnecessarily on the foil heating mats DON T install electrical cables or pipes under the floor with the foil heating mats DON T use cellulose insulation DON T install mats when the room temperature is below 5ºC DON T install foil heating mats anywhere except inside buildings DON T install foil mats under walls or partitions or in areas under heavy cabinets closets or fixtures toilet...

Страница 5: ...eral thermostats To calculate the amount of Amps in the room see tables in page 16 ALWAYS use insulation under the mats to reduce running costs and warm up time Check with your installer to determine the R value of the sub floor insulation layer If there is no insulation or if the R value of the insulation layer is lower than 0 57ft2 h F Btu 0 1m2 C W or 1 Tog please read the insulation instructio...

Страница 6: ... ma at t In some instances you may need to cut and turn the mat to suit the room I It t i is s e es ss se en nt ti ia al l t th ha at t y yo ou u d do o n no ot t c cu ut t t tw wi is st t o or r k ki in nk k t th he e h he ea at ti in ng g w wi ir re e To make a cut turn the mat over so that the loops are exposed Lift the wire out of the way when cutting Once the aluminium foil has been cut and t...

Страница 7: ...o extend the electrical supply cables Depending on insulation air flow overall heat loss within the room additional heating may be required 1 Clean all debris from the floor base 2 Insert Warmup Insulation Board 3 Clean all debris from the surface of the grout or insulating material 4 Roll out heating mats on top of the insulating material It is recommended to leave a gap of about 50mm from the wa...

Страница 8: ...d d b br ri id dg ge e t th he e g ga ap p b be et tw we ee en n t th he e s se ec ct ti io on ns s o of f m ma at t This is necessary in order to keep the ground circuit intact 6 Place the electrical supply cables of the mats between the mats toward the junction box Place the electrical supply cables so that they do not cross each other Important Ensure that the electrical supply cables of the ma...

Страница 9: ...ualified and Part P certified electrician Important Tightly screw all connections to ensure good electrical contacts 1 Install the electrical junction box or boxes above floor level according to local safety and building regulations and codes Place the following label attached to back cover on the electrical junction box or boxes indicating that an underfloor heating system is installed in the roo...

Страница 10: ...tween two heating wire runs on the mat at least 500mm from the wall Note Make sure that the sensor is placed between two runs of wire at the opposite end from the heating wire loop The probe wire must not touch or be crossed by the heating element 5 Measure the resistance of the heating system and record the value Verify that the values you measure are in line with the resistance value that is pri...

Страница 11: ... the leads but make sure the sticker with the leads numbers are affixed to the shortened lead 8 Expose the conductor in each lead 9 Connect all leads of the same colour 10 Insert each coloured lead to one connector in the junction box 11 Connect the same colour cold lead between the thermostat and the connector in the junction box WARNING This product MUST be used with a dedicated 30MA RCD residua...

Страница 12: ...in the thermostat box 13 Switch on the foil heating system see the directions in your thermostat manual for half an hour to ensure that the system is working properly It is important to check each entire system to ensure each foil mat is heating 14 Switch off the heating system see the directions in your thermostat manual 15 When the mats are cool lay down your floor covering ...

Страница 13: ...r the foil heating mats in installations with concrete subfloors to provide more efficient heating The material comes in plates usually made from foamed Polyurethane or Polystyrene and should have Compressive strength of more than 28PSI 2Kg cm2 An example of this is the Warmup Insulation Board Soft insulation material any soft insulation suitable for wood or laminate which has a fire rating of B2 ...

Страница 14: ...NOTES 14 ...

Страница 15: ...ng return the damaged heater to Warmup within 30 DAYS along with your original dated sales receipt WARMUP WILL REPLACE ANY HEATER MAXIMUM 1 HEATER WITH ANOTHER HEATER OF THE SAME MAKE AND MODEL FREE 3 If you damage the new heater during installation of the floor covering contact Warmup immediately to arrange for a site visit You will need to show our engineer your original dated sales receipt floo...

Страница 16: ...210 140 0 91 251 90 WLFH 140W 280 2 4 0 5 280 140 1 22 188 93 WLFH 140W 420 3 6 0 5 420 140 1 83 125 95 WLFH 140W 560 4 8 0 5 560 140 2 43 94 46 WLFH 140W 700 5 10 0 5 700 140 3 04 75 57 WLFH 140W 840 6 12 0 5 840 140 3 65 62 98 WLFH 140W 980 7 14 0 5 980 140 4 26 53 98 WLFH 140W 1120 8 16 0 5 1120 140 4 87 47 23 WLFH 140W 1260 9 18 0 5 1260 140 5 48 41 98 WLFH 140W 1400 10 20 0 5 1400 140 6 09 37...

Страница 17: ......

Страница 18: ...tion Manual and that the heater has been installed as specified therein I acknowledge that no claim can be brought against the manufacturer or its agents for any consequential loss or damage whatsoever I confirm that the heater was working prior to the commencement of tiling Signed Date other Kitchen Bathroom Conservatory Hall Fill in your registration online at www warmup co uk to receive your FR...

Страница 19: ......

Страница 20: ...of the heated floor emission of the heated floor Attention Do not cut or shorten the heating element wire Ensure that the entire heating elements including the joints are installed under the finished floor The Heating element must be used in conjunction with a 30mA RCD Heater Model Resistance Before Resistance After Insulation Resistance This form must be completed as part of the Warmup Guarantee ...

Страница 21: ...ssociated logos are trade marks Warmup Plc 2009 Regd TM Nos 1257724 4409934 4409926 5265707 E OE 702 Tudor Estate Abbey Road London NW10 7UW Web www warmup co uk Email uk warmup com Tel 0845 345 2288 Fax 0845 345 2299 V0310 ...

Отзывы: