background image

13

Heating

How to set into Manual Mode

Setting into manual mode allows you to set a fixed target temperature for 

the thermostat to achieve. The thermostat will continue to maintain this 

temperature until another operating mode or temperature is selected.

73

73

°

---

73

---

Sets the target temperature indefinitely.

Set the duration of the manual mode.

How to set a Temporary Override

Setting a temporary override allows you to set a target temperature which 

will override your current heating program until your next heating period or 

for a set duration.

73

°

17:00

20:00

73

Sets the override until next scheduled heating 

period.

Sets the duration of the override.

70

73

17:00

Содержание Terra WSC-1021

Страница 1: ...is done in a matter of seconds simply scan the QR code on the Terra thermostat using the MyHeating app and it will automatically connect to your WiFi network The Terra works with all of our advanced...

Страница 2: ...ll automatically connect to your WiFi network Weather based Early Start Turns the heating on at just the right time to be warm when you scheduled no overheating or wasted energy Takes into account the...

Страница 3: ...ectric Floor Heating and Baseboard Heating Maximum Load 15A resistive 120 V 1800W 240 V 3600W Standards UL 60730 1 UL 60730 2 9 UL 943 CAN CSA E60730 1 CAN CSA E60730 2 9 CAN CSA C22 2 No 144 1 FCC 47...

Страница 4: ...User Guide TerraWiFi Thermostat TM Smart Heating Simpli ed...

Страница 5: ...tial Setup 10 Welcome to the Terra thermostat 11 How to quickly change the temperature 11 How to quickly change mode 11 Heating 12 How to set a program 12 Setback Temperature 12 How to set into Manual...

Страница 6: ...ce installed q q q q Conduits are only required where it is mandated by state or provincial code Please refer to local electrical code for compliant applications The thermostat and its packaging are n...

Страница 7: ...ad Max 15A 1800W 120V 3600W 240V LINE L1 Supply Live 120 V LINE L2 Supply Neutral 120 V Supply Live 240 V P1 PC Probe 1 Floor Air Control Sensor No Polarity Floor or air temperature reading for schedu...

Страница 8: ...OUT of room Floor temperature schedule Floor limit P1 PC Floor Sensor P2 PC Floor Limit 7 Thermostat OUT of room Air temperature schedule Floor limit P1 PC Air Sensor P2 PC Floor Limit 8 Thermostat I...

Страница 9: ...Hot 120V Hot 120V or Neutral Heating 3600W 15A Heater earth connections should be connected to earth in line with NEC CEC code Option 1 Heating 3600W 15A into thermostat only R C Snubber not required...

Страница 10: ...al R C Snubber 0 1 8 6 4 2 Relay 1 15 A 6mA GFCI 20 A Heating 3600W 15A Option 2 Heating 3600W 15A into external relay only R C Snubber required RED Hot 120V White Neutral Heating RED 240V Yellow 120V...

Страница 11: ...8 6 4 2 6mA GFCI 20 A Heating 3600W 15A Heating 3600W 15A Heating 3600W 15A Option 3 Heating 3600W 15A into thermostat Heating 3600W 15A into external relay Additional relays can be added to circuit a...

Страница 12: ...w power up the thermostat 1 500W 1 2 System type 1 500W eUFH 2 000W hUFH 30 000W Conventional 1 500W eUFH relay Input wattage 1 500W 2 000W 30 000W 1 500W Input efficiency 90 90 Thermostat application...

Страница 13: ...ing App and scan the QR Code on the thermostat screen protector or on reverse of the display Follow the instructions in the App to complete setup Download the MyHeating App MyHeating by Warmup 1 2 Ste...

Страница 14: ...et a temporary override If in manual mode this will set a fixed target temperature See How to set into Manual Mode Once the target temperature is set above current floor air temperature the heating in...

Страница 15: ...appear below the day of the week Press to move to the next day 07 00AM 09 00AM 70 04 30PM 09 00PM 70 Press to set a program 07 00 09 00 70 Set the start time followed by target temperature and finall...

Страница 16: ...temperature is selected 73 73 73 Sets the target temperature indefinitely Set the duration of the manual mode How to set a Temporary Override Setting a temporary override allows you to set a target te...

Страница 17: ...stem manufacturer How Energy Monitor works SmartGeo SmartGeo is a unique technology developed by Warmup and built into the MyHeating App that uses an advanced algorithm to understand the most efficien...

Страница 18: ...obe Press to swap probe usage Press to confirm 3 See Table 1 0 Thermostat Application Press to change application Press to confirm 1 10K Change Control Sensor Probe 1 5 6 type Set between 5 10 12 15 1...

Страница 19: ...y when the thermostat detects that a window or door has been opened Display lock Switch display lock on 0 0 0 0 Set display lock code Switch display lock off WiFi WiFi Setup Open MyHeating App and sca...

Страница 20: ...arning Early start will use the historic heating cooling rates for the time of day historic external temperatures and the forecast external temperatures to work out the heating start time in order to...

Страница 21: ...re until heating is on the heat up icon will be illuminated and pressing the TEST button If your test is successful you will see the GFCI error icon and you will need to hold X for 3 seconds in order...

Страница 22: ...ach Does the thermostat connect to your WiFi Network Set up a mobile hotspot using a smartphone On a separate device login to the MyHeating app Try to connect the thermostat to this mobile hotspot Doe...

Страница 23: ...degree 2 Max Ambient Temperature 40 C 104 F T40 Relative Humidity 80 IP Rating IP30 Sensors Floor Air Sensor Type NTC10K 25 C Operating Frequency 2401 2484MHz Max Radio Frequency Power Transmitted 20...

Страница 24: ...ct or malfunction was caused by failure to follow the instruction manuals incorrect installation or damage which occurred while the product was in the possession of a consumer Warmup s sole responsibi...

Страница 25: ...mup UG Terra V1 4 2022 06 09_NAM EN Warmup Inc n 25 A Francis Clarke Circle n Bethel n CT n 06801 n US Warmup Inc www warmup com ussales warmup com T 888 927 6333 Warmup Canada ca warmup com T 888 592...

Отзывы: