9
•
Channel out a recess in the
wall for the connector block
and power supply cable of the
demister. This location should
have been marked on the wall
in Step 2.
1
The Warmup Mirror Demisters electrical connection
must conform to the current BS 7671 Wiring Regulations.
Final connections to the main electricity supply MUST be
completed by a Part P qualified electrician.
•
The supply should be
on a circuit protected by
a maximum 5 amp fuse
or circuit breaker. It is
recommended that the mirror
demisters supply is fitted with
an in-line isolator to allow it
to be independently isolated.
Please see Page 6 for correct
zoning.
•
The demister is a Class II
device and does not require
connection to earth.
2
NOTE:
If installing multiple heaters, they MUST be installed in
parallel, DO NOT connect in series. The power rating of the circuit
should also be checked to determine that the heaters will NOT
overload the circuit.
NOTE:
Any metal parts which are accessible and are in contact with
the mirror must be earthed in compliance with BS 7671.
Step 4 -
Make Electrical Connection