Installation Manual

Mirror Demister

Bathroom

Heating

 

Содержание Mirror Demister

Страница 1: ...e read this manual before attempting to install your Warmup product Complete and submit your warranty form online at www warmup co uk 0345 345 2288 TechnicalHelpline Installation Manual Mirror Demister Bathroom Heating ...

Страница 2: ...up Natural Language Programming Programming that speaks your language Please scan the QR code for more information The world s best selling floor heating brand Over 2 million installations in more than 60 countries EasySwitch Always on the best tariff automatically SmartGeo Smarter geo fencing Reduce energy usage by up to 25 ...

Страница 3: ...stallation is quick and straight forward but as with all electrical systems certain procedures must be strictly followed Warmup plc accepts no liability expressed or implied for any loss or consequential damage suffered as a result of installations which in any way contravene the instructions that follow It is important that before during and after installation that all requirements are met and un...

Страница 4: ... as part of your Warmup heating installation 30 mA Residual Current Device RCD required as part of all installations Digital Multi meter required for testing the resistance of the mirror demister Electrical tape Electrical housing back boxes and junction boxes Scissors Silicone Warmup Mirror Demister ...

Страница 5: ...ansion and contraction when heating Ensure any metal parts which are accessible and are in contact with the mirror are earthed grounded in compliance with BS 7671 Ensure the mirror being used is suitable for use with the Warmup Demister Contact mirror manufacturer for guidance Ensure that the edges of the demisters are at are at least 5 mm apart Cut or puncture the demister at any time Use a demis...

Страница 6: ...athroom installations electrical regulations prohibit the installation of Mains Voltage products such as thermostats contactors fused spurs isolators or junction boxes within Zones 0 or 1 This mirror demister has an IP rating of IP54 and is suitable for installation within Zone 2 Zone 3 or outside of any Zones All electrical connections must conform to the current BS 7671 Wiring Regulations Final ...

Страница 7: ...u begin If the mirror is mounted within the plane of the tiles ensure that it is surrounded with a minimum 3 mm bead of silicone to allow for mirror expansion and contraction when heating If fixing the mirror to the wall using adhesive or screws ensure flexible fittings are used either in the form of a flexible mirror adhesive or flexible bushings in the fixing holes if screwed to the wall NOTE If...

Страница 8: ...ference Resistance Band table on Page 18 Always handle mirrors with care Lay the mirror face down on a protective soft surface The back of the mirror must be clean dry and free from grease detergents or polish Peel 50 mm off the protective backing and position it so that it lines up with your markings on the mirror back Press the demister into the back of the mirror smoothing out any air pockets b...

Страница 9: ... fuse or circuit breaker It is recommended that the mirror demisters supply is fitted with an in line isolator to allow it to be independently isolated Please see Page 6 for correct zoning The demister is a Class II device and does not require connection to earth 2 NOTE If installing multiple heaters they MUST be installed in parallel DO NOT connect in series The power rating of the circuit should...

Страница 10: ...A RCD or RCBO N L N L N Controller Mirror Demister Max 5A Fused Isolator Switch The Warmup Mirror Demister can be connected into the rooms lighting circuit enabling the demister when the lights are switched on Alternatively they can be controlled by an independent controller that provides power on demand 3A 3B ...

Страница 11: ...ections are not trapped behind the mirror which would cause the mirror to be stressed or sit unevenly on the wall Once mounted seal around the edge of the mirror with silicone NOTE Alterations or cuts are made to the mirror may cause cracking when installed in conjunction with the Warmup Mirror Demister and are not recommended Alterations include A rectangular hole for a switch outlet or other app...

Страница 12: ...rors surface then the demister is working Please see the Performance Troubleshooting Guide Are the wiring connections from the demister to the power supply secure Rewire the demister to the power supply Mirror Demister has been damaged and may need replacing NO NO NO YES YES YES HEATING ISSUE 2 The demister trips the RCD ELECTRICIAN Mirror Demister has been damaged and may need replacing Conduct a...

Страница 13: ... demister and brick tile or cement walls to avoid heat transfer away from the mirror 1 Old mirrors may not be suitable for use with Warmup Mirror Demisters Before applying a mirror demister to any mirror its suitability with a demister should be checked with the mirror manufacturer 2 Check that there is suitable expansion space around the perimeter of the mirror that fixing are flexible not rigid ...

Страница 14: ...resistance is within the Reference Resistance Band shown on Page 18 for the demister being tested Record the readings on the control card on Page 16 in line with the installation procedure NOTE Due to the high resistance of the demister it may not be possible to get a continuity reading from the demister and as such continuity testers are not recommended When checking resistance make sure your han...

Страница 15: ...uch cost does not extend to any cost other than direct cost of repair or replacement by Warmup and does not extend to costs of replacing or repairing any mirror s If the demister fails due to damage caused during installation this guarantee does not apply It is therefore important to check that the demister is working as specified in the installation manual prior to mounting the mirror WARMUP PLC ...

Страница 16: ...demister at any stage The demister must be supplied from a circuit protected by a 30mA RCD and 5 A MCB or RCBO Demister Model Resistance Before Resistance After Date Signed Company stamp name This form must be completed as part of the Warmup Guarantee Ensure that the values are as per the instruction manual This card along with a plan showing the demister position must be situated close to the con...

Страница 17: ...17 Layout Plan NOTE Draw a plan showing the location of the demister s on the back of the mirror ...

Страница 18: ...SS 0 4 mm AVERAGE TEMPERATURE RISE 25 C INPUT POWER 200 W m CONNECTION 1 5 m LONG COLDTAIL CONNECTION Warmup Mirror Demisters PRODUCT CODE SIZE mm POWER W LOAD A RESISTANCE Ω MD SML1 260 x 360 14 1 0 06 3751 MD MED1 360 x 560 33 3 0 14 1589 MD LRG1 560 x 720 66 0 0 29 801 Mirror Size Guide REFERENCE RESISTANCE BANDS Ω 3375 9 4126 1 1430 1 1747 9 720 9 881 1 ...

Страница 19: ..._______ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ __...