9
www.warmlite.co
TROUBLE SHOOTING
Safety Cut-Out device:
To ensure against the potential hazard caused
by blockage of the air outlet, this unit is
equipped with an automatic over-temperature
safety cut-out device. When the device is
activated the heater will not operate. If this
occurs, the unit can be reset using the following
procedure.
1. Turn the fire off by depressing the on/off
switch on the unit.
2. Unplug the power cord form the electrical
mains supply socket and leave it
disconnected for at least 10 minutes.
3. Ensure that the air vents are free from
obstruction.
4. Plug the power cord back in to the mains
socket.
5. Turn the fire back on.
6. If the fire fails to operate, check the fuse in
the plug.
7. If the fuse in the plug is OK and the fire
is still not functioning, contact a qualified
service person.
Problem
Potential cause
Corrective action
The fire won’t turn on.
Mains plug is not plugged
in.
The On/Off switch hasn’t
been switched on.
The fuse in the plug has
blown.
Check the mains socket to
ensure the plug has been
inserted correctly.
Switch on using the
operation switches.
Check and change the fuse
in the plug.
No heat.
One or both of the heat
selector switches haven’t
been switched on.
Ensure that the heat
selection switches have
been correctly switched on.
Heater operates and then
the heat cuts out.
The safety cut-out may
have operated.
Follow the procedures as
outlined in the “safety cut
-out device” section.