14 June 2016
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
All Dimension are in mm
7
Your Fire must be Installed and Tested by a suitably qualified Gasfitter prior to use.
To light :
Lower the control-cover by pulling it outwards.
Depress the Ignition Switch and hold in the
'PILOT'
position for 3-5 seconds. (This may take some time for the Gas to come
through to the Pilot-3 Flame)
Strike the Igniter by turning to the
'STAR'
position, maintaining the Switch in a Depressed State ; (repeat steps 2 & 3 if necessary)
Once the Pilot Flame is lit, hold this position for 3-5 seconds , release from the Depressed State before setting the Flame Control
to Full, it may take 3-5 seconds for the Burner to Light.
Once the Flame Bed is established, set the Flame Control to the desired level & close cover.
To shut down :
Open control cover by pulling it outwards.
Turn control switch to
'PILOT'
. Flame bed will extinguish.
Pilot light may be left running or extinguished by switching to
'OFF'
before closing cover.
OPERATION OF YOUR WARMINGTON GAS CONVECTION FIRE (SG ONLY)
Optional:
Seismic Restraint
Secure Burner through 4X anchor points
provided on Burner Side Plate Bases
OPTIONAL: BURNER RESTRIANTS.