Description 

  

SN 900 

SN 1500 

SN 1250 

SN 1100 

Firebox Width 

900 

1500 

1250 

1100 

Firebox Height 

760 

910 

910 

760 

Firebox Depth 

450 

600 

600 

450 

Flange Width 

950 

1550 

1300 

1150 

Flange Height 

785 

935 

935 

785 

Adaptor Height 

425 

480 

480 

425 

WARMINGTON NOVEAU FIREBOX DIMENSIONS

 

HEBEL SURROUND DETAILS DIMENSIONS

 

Description 

 

 

SN 900

 

SN 1500

 

SN 1250

 

SN 1100

 

Surround Width 

G

 

1110 

1710 

1460 

1310 

Surround Height 

H

 

1325 

1640 

1640 

1325 

Surround Depth 

I

 

635 

770 

770 

660 

Window Width 

J

 

960 

1560 

1310 

1160 

Window Height 

K

 

790 

940 

940 

790 

To Centre of Flue 

N

 

312 

387 

448 

312 

Flue Diameter 

O

 

300 

450 

350 

350 

Liner Diameter 

P

 

400 

550 

450 

450 

Flue Centre           

(From front face of Firebox Flange )

 

Z

 

272

 

272

 

408

 

347

 

Minimum Flue Height

 

  

Flue Height 

2400 

Measured From Top of Adaptor 

B + F + 2400 

Check List

 

 

 

Firebox 

 

 

Ash Pan 

 

 

Rack/Hotplate & Grill 

 

 

Weather Shield 

 

 

Badge 

 

 

Adaptor & Bolts 

 

 

Packed by 

 

 

Note:

 

Firebox is recessed 40mm into Hebel Surround.

 

Description 

 

 

SN 900

 

SN 1500

 

SN 1250

 

SN 1100

 

Hearth Width 

L

 

1450 

1900 

1650 

1650 

Hearth Projection 

M

 

380 

850 

850 

380 

HEBEL HEARTH DIMENSIONS

 

Note :

 

• 

“Z” dimension is from Flue Centre to Firebox Front Flange Not 
including 40mm rebate from Hebel Enclosure .

 

 

• 

“N” dimension is from Flue Centre to the Hebel Enclosure front

 

Содержание Nouveau BBQ 900

Страница 1: ...current Installation details for the Warmington Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or an Approved NZHHA Installation Technician See www homeh...

Страница 2: ...d to the manufactures Instructions Installation Notes A rebate of 40mm is recommended from the front face of the surround to the front of the fire to reduce the ingress of water into the fire Due to t...

Страница 3: ...eight H 1325 1640 1640 1325 Surround Depth I 635 770 770 660 Window Width J 960 1560 1310 1160 Window Height K 790 940 940 790 To Centre of Flue N 312 387 448 312 Flue Diameter O 300 450 350 350 Liner...

Страница 4: ...through to the floor with the bolting point pro vided on the Left and Right hand sides of the fire box seismic restraints 4 Fit the Adaptor to the Fire box Ensure that exhaust sealant is used between...

Страница 5: ...adding must be con structed to suit an outdoor environment as per NZ building code Firebox is recessed 40mm into Hebel Surround External air intake vent required 2x 100mm diame ter at the base CAITEC...

Страница 6: ...48 387 BLOCK PLAN FRONT ELEVATION CROSS SECTION Note Centre Line of Flue is NOT in Centre of Alcove Firebox SN 900 SN 1100 SN 1250 SN 1500 Hearth Width RR 1590 1650 1650 1900 Hearth Projection SS 380...

Страница 7: ...h Width TT 1210 1210 1610 1610 Plinth Depth UU 600 600 700 700 Hearth Width RR 1590 1650 1650 1900 Hearth Projection SS 380 380 850 850 Window Height VV 790 790 940 940 Window Width WW 960 1160 1310 1...

Страница 8: ...breglass mesh with a latex plaster to minimise the chance of the plaster cracking See your plasterer for correct materials and applications Note HEBEL KITSET ASSEMBLY Details When purchasing the Hebel...

Страница 9: ...assembly guide comes with the Kit These Hebel Kits are not designed to be load bearing HEBEL HEAT CELL CUT SIZES FROM PANELS for SN1500 The Hebel Heat cell is constructed around the firebox using 75m...

Страница 10: ...are fitted that the Top of the Flashing Cone and the Flue Pipe are flush or that the Flue Pipe is 5mm lower than the Flashing cone 2 Fit the Top Spider into position ensure that the legs of the Spider...

Страница 11: ...ashing Butynol Dectite an Additional Flue pipe Baffle is required All external air vents ceiling penetrations must be bird proofed with permanently fixed screens All flashing to comply with E2 Test Re...

Страница 12: ...SE FLASHING AND AIR VENTILATION OPTIONS VENTING THROUGH CHIMNEY CHASE VENTING THROUGH FLASHING No Insulation under flashing Insulation under flashing CHIMNEY CHASE FLASHING DETAILS Note Flashing Spigo...

Страница 13: ...opyright on all products and Specifications 13 FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE Option X Singled Lined Flue System Option Y Double Lined Flue System The Flu...

Страница 14: ...n all products and Specifications 14 Note For Combustible Floors Minimum Hearth of 380mm A must be maintained Combustible Floor Important Note All Load Bearing Structures are to be Engineered to carry...

Страница 15: ...n matter by lighting or igniting the fire or Burner ENSURE THAT THE OUTDOOR FIRE IS WELL VENTILATED WHEN LIGHTING FOR THE FIRST TIME and operate fire on high for up to 5 minutes Cooking may proceed af...

Отзывы: