![Warmington Gas Nouveau SN 900 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/warmington/gas-nouveau-sn-900/gas-nouveau-sn-900_installation-instructions-and-service-manual_3407195004.webp)
23 April 2018
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notifi-
All Dimension are in mm
…….
Copyright on all products and Specifications ©
4
PLAN, FRONT ELEVATION & CROSS SECTION
Visit the Warmington website for
‘
Hebel
’
instruction
PDF sheet at www.warmington.co.nz
This is a general installation guide only –
Contact a
‘
NZHHA Installer
’
for installation advice.
See: www.homeheat.co.nz , choose
“
members
” &
pick your Area & Fire type (wood / Gas etc) this will provide you with a
NZHHA Certified Installer (use the SFAIT Installers only).
HEARTH & PLINTH CONSTRUCTION DETAILS
1.
All the dimensions are minimums
2,.
Fit the Plinth into position in the Cavity. If onto a wooden floor ensure that an insulating plinth is fitted as
per the specifications.
Ensure that the plinth is elevated to allow for finishing on the hearth. (See
Hearth and plinth details).
1.
Fit the firebox into the cavity. Bolt the firebox to the plinth or through to the floor with the bolting point pro-
vided on the Left and Right hand sides of the fire box (seismic restraints).
2.
Fit the adaptor to the firebox. Ensure that exhaust sealant is used between the fire and adaptor. Bolt into
position with the bolt in the Left and right hand sides of the firebox.
3.
Install the flue system.
4.
Fit the Hebel Heat cell around the fire. A general minimum lay out is shown in this Specification.
FIREBOX INSTALLATION
Note: Hearth and Plinth Construction
For Combustible flooring an insulating hearth and Plinth
of 75mm Hebel is required.
Plinth to be Offset above Hearth by the Hearth Finishing’s
( e.g. Tiles /Granite /Solid Plaster /etc )
All load bearing cantilevered Hearths must be Engineered
to carry loads.
IMPORTANT NOTE:
Offset
Offset for
Hearth
finishing
*Note: If Solid Plastering the structure, it is recommended to use a Fibreglass Mesh with a Latex Based Solid Plaster to
minimise the chance of the Solid Plaster cracking. (See your Solid Plasterer for correct materials and applications).
This is an example of a raised & cantilevered
Hearth. See page 15 for further raised Hearth
details.
This Hearth
& Plinth set-
up is at
floor level
Hearth