8
60K – 120K BTU System with FLKV12
Original Series: CFB60, CFB84, CFB120 | Linear Series: CFBL90, CFBL110 | H-Style Series: CFBH120
Any custom burners between 60K - 120K
FOR PUSH BUTTON IGNITION INSTRUCTIONS: Follow Match Lit System installation instructions. When finished, turn
to page 25 for Push Button Ignition installation instructions.
•
Select key valve location on your fire pit.
•
Plumb your existing gas supply into one side of your key valve.
•
Position your preferred support materials for the burner & plate inside of your fire pit (i.e., cinder blocks, elbow
brackets, etc.)
•
Warming Trends recommends a 4” clearance from the finished top of your fire pit (capstones) to your plate.
•
For Match Lit burners, Warming Trends
TM
recommends a minimum 6” clearance below plate for
additional connections.
•
For Electronic Ignition burners, Warming Trends
TM
recommends a minimum of 16" - 20" clearance below plate
for additional connections.
•
Use thread sealant that is resistant to all gases on all fittings except flared fitting to flex line connections.
•
Be sure to tighten every joint securely. Use thread sealant where required.
•
Perform leak tests on all fittings before turning on ignition.
B
R
A
S
S
B
U
R
N
E
R
S
60K – 120K BTU System with FLKV12
4” Key
12” Key
Key Valve
Pressure
Face Plate
Flex Line
STEP 1:
Locate FLKV12
Parts include 1/2” flex line, key valve and keys (4 and 12 inch.)