Warm4Less One-Click Скачать руководство пользователя страница 3

Warm4less One-Click 

www.warm4less.com

 

 

[email protected]

 

 01205 821 796 

Holiday Mode: 

Hold down the rotary button for 3 seconds, select the   button to enter holiday mode. Select your 

preferred days, and temperature and pressing the rotary button to confirm each selection. The temperature range is 

between 5~15

 (default 10

). Holiday mode can be cancelled by pressing  .

 

Evening-Saving Mode: 

Hold down the rotary button for 3 seconds, rotate the button to select the   option to enter 

the evening-saving mode. Rotate the button to set the preferred temperature (default 17 degrees), press the button 

to confirm the selection and when returning to the last interface, it will skip the next setting icon   automatically. 

 

Comfort Mode: 

When entering the mode selection, rotate the dial to choose   and press the rotary button to select 

comfort mode. The temperature can be adjusted (default 17 degrees) to suit and by pressing the rotary button it will 

automatically skip the last interface option 

.  

 

Receiver Comments: 

 

Power light: Green light illuminated 

Signal Light: Orange light within 10s after the power comes on (matching IP). The signal light turns off when it matches with the 
controller. The orange light will blink within 10s when the power turns off. 

 

Fault/load light: Red light 

 

IP connection is faulty (IP: FFFF). This red light will blink 2 times (0.25 seconds spacing). 

 

This light will blink 3 times when it does not receive wireless signal for 1 hour (0.25 seconds spacing).  

This light will blink 4 times when the external sensor is faulty (0.25 seconds spacing). 
External sensor temperature alarm for electric/water/underfloor heating:  

 

The detected temperature by external sensor is above the setting temperature of A5 (Advanced options), this will in turn 

then trigger high temperature protection and  will flash. 

 

Detected temperature by external sensor is below setting temperature of A6 (Advanced options). This will then trigger low 
temperature protection and appear ,it will auto open relay to heat and the   will reappear 

 

Advanced One-Click Options

Hold down the rotary button for 3 seconds, enter the advanced option setting by 

rotating the button to advanced 

, and press the dial.

 

Symb

ol 

Setting item 

Setting parameter 

Default 

A1 

Measuring temperature 

calibration 

-9 -+ 9

 

Accura

cy is 

0.5°C 

A2 

Temperature control 

return difference setting  

0.5 - 5

 

0.5 

A3 

Children lock 

0: Half lock 

1: Full lock 

A4 

Programmable choice 

--: Non-programmable  

01: Programmable 

01 

A5 

Limit value of high 

temperature for external 

sensor 

--: Cancel high 

temperature protection 

35°C - 70

 

-- 

A6 

Limit value of low 

temperature for external 

sensor 

--: Cancel low 

temperature protection 

5

℃ 

- 10

 

5

 

A7 

Lowest temperature 

limit setting 

1-

 

10

 

5

 

A8 

Highest temperature 

limit setting 

20 - 70

 

35

 

A9 

Descaling function 

0: Closed 

1: Open 

 (Auto 100 Hrs) 

 

AA 

Restore factory defaults 

Display A 0, press the 

rotary button. 

 

 