Deleting learned-in products (receivers) from the WMS network
Devices that do not need to be deleted must be de-energised. If you delete a receiver from the network, it can no longer
be operated via other transmitters. It must be learned into a network again.
W
ak
e up
transmitt
er
Briefly press the product button
Product button flashes, e.g. external venetian blind.
S
tar
t
scan pr
ocedur
e
5s
Press the L button for approx. 5 s
+
+
The L LED lights up green and
transmission LED flashes, red running light under the row of
numbers 0-9.
Select receiv
er
Briefly press the up or down arrow button
e.g. LED 1 flashes.
LED green = receiver already belongs to the network.
Identify receiv
er
Briefly press the i button
Product waves, repeat the previous step if necessary until the
desired product waves.
Dele
te
receiv
er
+
Briefly press stop button and C button
simultaneously
Running light under row of numbers lights up.
Product waves.
Confir
m dele
-
te command
Briefly press the L button
LED 1 flashes red, receiver is in factory setting again.
Com
ple
te
pr
ocess
kurz
Briefly press the L button
Process is completed