background image

Maintenance

WAREMA Renkhoff SE - Hans-Wilhelm-Renkhoff-Straße 2 - 97828 Marktheidenfeld - Germany

www.warema.com - [email protected]

6

Maintenance

Proper and regular cleaning and the use of original spare
parts only are essential for fault-free operation and a long
service life.

CAUTION

Risk of injury from falling from climbing aid!

Climbing aids may tip over if they are improperly
erected.

Position climbing aids on level and firm ground.
Do not rest climbing aids against the product.

6.1

Cleaning

To ensure the longest possible life, we recommend
that you clean the surface of the product regularly or
at least once a year.

If the first cleaning takes place several years after
initial installation, the product or fabric cannot be
restored to its original condition.

Replacement claims cannot be honoured on the
grounds of these cleaning instructions because the
effectiveness of these measures depends on a large
number of factors that vary from case to case.

Always follow the manufacturer instructions when
using chemical cleaning products. In the interest of
the environment, it is recommended that you only
use 100% biologically degradable cleaning products.

NOTICE

Product damage from incorrect cleaning!

Incorrect cleaning procedures may result in damage
to the product or product parts, and the surfaces and
structures may be permanently altered.

Do not use abrasive cleansers or sponges and

solvents such as alcohol or naphtha.

Remove dust from the surfaces using a soft

brush or feather duster.

Clean the surfaces with a suitable cleaning

agent.

6.2

Warranty

Subject to the statutory period of limitation for warranty
claims. This requires regular maintenance. The warranty
does not include wear parts or optical changes in line

with the type of material used (e. g. bleaching of surfaces
caused by UV rays).

6.3

Spare parts/repairs

INFO

To ensure that your product will operate properly
on a continuous basis and to avoid changing
its approved status, use original spare parts
only. Contact your WAREMA specialist dealer if
necessary.

Содержание FS

Страница 1: ...d blind with cord operation Type FS S1 S2 XR1 Instructions for installation use and maintenance To be handed over to the operator Please keep for future use Valid from 22 March 2016 Document number 2007644 Rev 4 en ...

Страница 2: ... 1 3 Basic safety instructions 3 2 Installation FS S1 S2 XR1 without cable guidance 4 2 1 Overview 4 2 2 Rabbet installation 4 2 3 Angle bracket installation 5 3 Installation of FS with cable guidance 6 3 1 Rabbet installation 6 3 2 Angle bracket installation 7 4 Winding systems 8 5 Operation with lifting cord 9 5 1 9 6 Maintenance 10 6 1 Cleaning 10 6 2 Warranty 10 6 3 Spare parts repairs 10 ...

Страница 3: ...These instructions contain important information on the handling installation commissioning operation care and maintenance of this item Other versions or special solutions are not dealt with Permissible activities Performing tasks on the product that are not described in these instructions is not permissible No other alterations additions conversions or maintenance work is to be carried out on the...

Страница 4: ...07644 Rev 4 en 2016 03 22 2 Installation FS S1 S2 XR1 without cable guidance 2 1 Overview Type FS Type S1 S2 Type XR1 35 90 35 90 35 35 90 35 35 2 2 Rabbet installation Measuring and drilling the fixing points 15 mm 3 mm 3 mm 3 mm 15 mm 17 mm 3 mm 3 mm 3 mm 17 mm ...

Страница 5: ...idance 2007644 Rev 4 en 2016 03 22 Page 5 10 Installing the pleated blind 1 2 3 4 see Chapter 4 Page 8 Dismantling 1 2 3 Angle bracket installation Measuring and drilling the fixing points x x 2 mm x x 2 mm Installing the pleated blind 1 2 3 4 ...

Страница 6: ...6 03 22 5 6 see Chapter 4 Page 8 Dismantling 1 3 Installation of FS with cable guidance 3 1 Rabbet installation Measuring and drilling the fixing points 15 mm 3 mm 3 mm 3 mm 15 mm 15 mm 15 mm 17 mm 3 mm 3 mm 3 mm 17 mm 15 mm 17 mm Installing the pleated blind 1 2 3 1 2 4 ...

Страница 7: ...ble guidance 2007644 Rev 4 en 2016 03 22 Page 7 10 5 6 see Chapter 4 Page 8 Dismantling 1 2 3 1 2 3 2 Angle bracket installation Measuring and drilling the fixing points x x 2 mm x x 2 mm Installing the pleated blind 1 2 3 4 1 2 ...

Страница 8: ...rd must be fixed to the wall at least 1500 mm above the floor Installation procedure Transfer the fixing points of the cord winders to the mounting substruc ture Attach the cord winders to the mounting sub structure Push the cover caps into the cord winders Procedure for securing the pull cord Wind all of the pull cord around the two halves of the cord winder ...

Страница 9: ... reach of young children Cords may become wrapped around the neck of a child Move beds cots and furniture away from the cords of window coverings Do not tie cords together Make sure cords do not twist and create a loop 1 2 3 4 5 6 Raise and lower the pleated blind by pulling the lifting cord Wind all of the lift ing cord around the two halves of the cord winder Assembling the safety cord tassel Ca...

Страница 10: ...ber of factors that vary from case to case Always follow the manufacturer instructions when using chemical cleaning products In the interest of the environment it is recommended that you only use 100 biologically degradable cleaning products NOTICE Product damage from incorrect cleaning Incorrect cleaning procedures may result in damage to the product or product parts and the surfaces and structur...

Отзывы: