Fig. 4  Wall mounting

 

 

Clip one of the included spacers in the threaded hole 

(horizontally or vertically, Fig. 2).

 

 

Attach the weather station to a suitable substructure 

using the included screws and dowels as shown 

(Fig. 4).  

The connecting cable must be correctly positioned in 

the guide on the back of the mounting plate to ensure 

it is not pinched during installation.

Ceiling installation

Fig. 5  Ceiling installation

 

 

Loosen the screw on the weather station joint.

 

 

Swing the mounting plate of the weather station up by 

90° (or by the necessary angle).

 

 

Tighten the screw on the joint.

 

 

Clip one of the included spacers in the threaded hole 

(horizontally or vertically, Fig. 2).

 

 

Attach the weather station to a suitable substructure 

using the included screws and dowels as shown 

(Fig. 5).  

The connecting cable must be correctly positioned in 

the guide on the back of the mounting plate to ensure 

it is not pinched during installation.

Pole installation

Fig. 6  Pole installation and steel cable ties locking mechanism

 

 

 

Remove the thin (triangular) pieces at the top and 

bottom edge of the mounting plate using a wire cutter 

(Fig. 6 

*

).

 

 

Pass the included steel cable ties through the mount-

ing plate openings as shown. The cable tie closures 

must face outward.

 

 

Turn both ends of the cable tie inwards, one at a time, 

using needle-nosed pliers.  

Check that the weather station cannot be turned. 

 

 

Check that the weather station cannot be turned. 

Содержание EWFS Weather station plus

Страница 1: ...un shading products before maintaining or cleaning the products CAUTIO C Never activate buttons on your transmitter arbitrarily without visual contact to the sun shading product Children may not play with this product Remote controls or transmit ters may not get into the hands of children NOTICE N The receiver e g the radio plug receiver radio tubular motor cannot function in the event of a power ...

Страница 2: ... metal enclosures must have a distance of at least 0 5 m from the weather station Install the device in a position in which the wind current sensor is horizontal housing inclination of 15 When installing the device on sloped surfaces the sensor can be positioned horizontally using the joint Fig 1 When selecting an installation location ensure that precipitation can fall onto the sensor surface fro...

Страница 3: ... on the joint Clip one of the included spacers in the threaded hole horizontally or vertically Fig 2 Attach the weather station to a suitable substructure using the included screws and dowels as shown Fig 5 The connecting cable must be correctly positioned in the guide on the back of the mounting plate to ensure it is not pinched during installation Pole installation Fig 6 Pole installation and st...

Страница 4: ...he cover is thinner at the location designed for this purpose Operating elements 6 7 9 8 10 Fig 8 Operating elements view from below factory setting 6 Wind Wind speed limits can be preselected using this switch 7 LED Flashes green when the L button is pressed Flashes red three at a time while a wind alarm is active Flashes red three at a time while a wind alarm is active Lights up green when the p...

Страница 5: ...ter wait until the connected sun shading system moves and then release the button immediately Learning in the weather station The weather station sends wind brightness and precipita tion related move commands to an EWFS Receiver It must be learned into the receiver first NOTICE N The weather station can only be learned as an auxiliary channel Example You would like to operate an external venetian ...

Страница 6: ... again separately NOTICE N If a sensor that has already been learned in is learned in again it is learned out Example During the learning procedure only the precipitation and wind sensors were learned in If the learning procedure is re peated the photo sensor is learned in but the precipitation and wind sensors are learned out Ι Ι 1 Test the wind monitoring function Move the Wind switch on the wea...

Страница 7: ...stem should now move up If the sun shading system does not move during this test precipitation monitoring was not learned in Learn in precipitation monitoring again separately see Learning in functions individually NOTICE N In this test EWFS tubular motors do not re spond when the button is pressed Learning in functions individually If problems arose when learning in the weather station of a sun s...

Страница 8: ...on The sun control is now learned into the sun shading product Return the wind monitoring setting back to the original value Ι Ι Learning in precipitation monitoring individually Perform the following steps consecutively Place receiver 1 into learn mode Take the hand held transmitter into which the master channel was learned I press and hold the learn button external roller blind 1 waves once rele...

Страница 9: ...een learned in using the A button Press the A button and hold until the sun shading sys tem stops moving Release the button again The sun control is now switched off for 12 hours After this period the sun control is reactivated again auto matically To reactivate the sun control with the A button Press and hold the A button Release the button again when the sun shading system waves The sun control ...

Страница 10: ... vibrations at the installation location for exam ple from frequent high wind loads can loosen the fixing screws If the joint screw is not properly tightened the orientation of the weather station may change as well Therefore check from time to time that the weather station is still firmly installed and that all screws are sufficiently tight Liability Failure to comply with the product information...

Страница 11: ... voltage 85 230 253 V AC Frequency 50 60 Hz Power consumption 3 W RF transmitter Transmission frequency 433 92 MHz Transmission power 10 dBm Range environment without interference 30 m Wind measurement Wind speed 2 25 m s Locked time in case of wind alarm 10 min Brightness measurement Brightness 5 100 klx Switch off delay if brightness falls below 60 of the set limit value 10 min Enclosure Dimensi...

Страница 12: ...ading system does not move up in cloudy weather The brightness limit value is set too low Increase the value incrementally The sun shading system does not move up during precipitation Precipitation monitoring is switched off Switch precipitation monitoring on at the weather station the status LED must light up green permanently The sun shading system retracts although there is no precipitation The...

Отзывы: