background image

POD33

 

DARS GENERATOR

 

 

OVERVIEW

 

 

POD33

is a Digital Audio Reference Signal (DARS) generator. This DARS reference signal can

     

 

 

 

 

 

 

 

 

 

 

 

be synchronized to an external Video or AES reference or it can be synched to an internally

 

   

 

 

   

 

     

 

 

   

 

 

generated 96 kHz or 48 kHz reference.

POD33

is designed to selectively provide a 100 Hz, 400

 

 

     

 

 

   

   

 

   

 

 

 

Hz or 1 kHz tone at amplitudes ranging from Digital Silence through ­60 dBFS to 0 dBFS.

 

 

POD33

has four independent digital outputs. Each output is available as an unbalanced 75

 

 

 

 

 

 

 

   

 

 

 

 

 

Ohm or balanced 110 Ohm signal. These outputs can be individually set to be either an AES

   

 

 

 

 

 

 

 

 

 

   

 

 

 

 

reference or a Word Clock signal. The level and frequency for each individual output can be

     

 

 

 

 

 

 

 

 

 

 

 

 

 

set. 

 

 

All controls and read­outs are located on the front panel. Input, output and power connections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

are located on the rear panel. Phoenix 3­pin pluggable connectors are provided for the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

balanced AES signals and unbalanced AES and video reference connections are made via

 

 

 

 

 

 

 

 

 

 

 

 

 

BNC type connectors.

 

 

FRONT PANEL CONTROLS AND TALLIES

 

 

The operable controls and tallies located on the front panel include:

 

1

A power ON/OFF switch and green LED that illuminates when the unit is powered

 

 

 

 

 

 

 

 

 

 

 

   

 

up. 

 

2

Three tallies labeled

AES

,

VIDEO

and

INTERNAL

illuminate to indicate the type of

 

 

 

 

 

 

 

   

 

 

   

reference that is selected. If a reference tally is illuminated but flashing it indicates

 

   

     

 

   

 

 

   

 

that the selected reference signal is not available. POD33 will automatically search

 

 

 

 

   

 

 

 

 

 

 

for and switch to the next available reference signal. The search hierarchy for

 

 

   

 

 

 

 

 

 

 

 

 

reference signals if

AES

is selected is

AES – VIDEO – INTERNAL.

If

VIDEO

is

 

   

   

   

   

   

   

   

selected the search hierarchy is 

VIDEO – AES – INTERNAL.

 

3

Two shaft encoder rotary controls labeled

SELECT

and

ADJUST.

Each rotary

 

 

 

 

 

 

 

 

 

 

 

control has an integral push­push switch

 

4

A sixteen character LED dot­matrix readout. 

 

 

OPERATION

 

When the unit is first powered on the read­out displays

Pod 33 VXXX.

(

VXXX

is the operational

 

 

   

 

   

 

 

 

   

 

   

 

 

software version identification and should be noted when calling the factory for technical

 

 

 

 

 

 

 

 

 

 

 

 

 

assistance) After a brief period the default status display appears which shows the levels for

 

   

 

 

 

 

 

 

 

 

 

 

 

 

the A and B channels of the AES 1 signal.

 

 

The

SELECT

control allows you to scroll through the four DARS outputs (AES 1 to AES4) and

 

 

 

 

   

 

 

 

 

 

 

     

 

 

display the settings for that output. For example AES 2 is selected and the readout shows

 

 

 

 

 

 

 

 

     

 

 

 

 

 

AES2 A/B ­20/­10.

This means that on the AES2 reference output the level of the A channel is

 

 

 

 

 

   

 

 

 

 

 

   

   

   

set to ­20dBFS and the level of the B channel is set to ­10 dBFS

.

To view the frequency

   

 

 

 

   

   

   

   

 

 

 

 

 

 

settings for the AES 2 output push the

ADJUST

knob once. The readout should change to

 

 

 

   

 

 

 

 

 

 

 

 

 

   

display the frequency settings for AES 2. For example if the display reads

AES2 A/B 1k/400

 

 

 

 

 

   

 

   

 

 

 

 

 

 