Safety—Operation Precautions
T7M7G6M,000085F -19-25APR22-1/1
T7M7G6M,000085E -19-29MAR22-1/1
To activate manual mode
1. Turn the Waratah switch to the ‘On’ position.
XJ1321698
—UN—15MAR22
TimberRite H-16
2. In TimberRite H-16, go to page 2.1.C.2 ‘Manual pump
test’.
3. Set the desired current value for each pump, then
press the
Start
button to activate.
4. With supply pressure and flow at the head, the
required function can be activated by:
- For Parker valves, plugging in a 24V DC/1A power
supply into the solenoids.
- For Danfoss valves, shifting the spools with the
manual actuators.
5. When testing is complete, press the
Stop
button on
page 2.1.C.2.
IMPORTANT: When in the manual mode, pressure
and flow are supplied at the head via the
H-16 pump outputs, but all harvester head
controls are disabled. Manual mode also
locks out base machine function.
H-16 Controller Power
The H-16 system has separate switched and unswitched
power networks. The primary switched 24 V network
powers the solenoids that control head movement, via
the software. The constant unswitched 24 V control
network (stepped down to 5 V to run the circuits) allows a
soft shut-down when the Waratah switch is turned off. It
cannot supply power to the solenoids.
1-3-7
053122
PN=29