9
SPS-TG, SPK-TG, SPM-P-TG, SPM-S-TG
To close the sluice gate, turn the operating device clockwise until a natural resistance
is met. The sluice gate opening is fully closed slightly before reaching the end of the
sluice gates travel. Applying high torque on the handle will not improve sluice gate
performance and can lead to permanent damage.
To open the sluice gate, turn the operating device anti-clockwise until a natural
resistance is met. The water pressure pressing on the sluice gate can give a reasonable
amount of resistance to initial movement, but this is completely normal behavior. The
sluice gate is fully open when a resistance is met.
GENERAL OPERATION
MTV & SPS-TL
To close the gate push gently on the gate handle until a natural resistance is met.
The gate opening is fully closed slightly before reaching the end of the gates travel.
Pressing hard on the handle will not improve gate performance and can lead to
permanent damage.
To open the gate, pull on the gate handle. The water pressure pressing on the gate
can give a reasonable amount of resistance to initial movement, but this is completely
normal behavior. The gate is fully open when a resistance is met.
Never use heavy equipment to move the gate, as excessive force can permanently
damage the gate.
DN/NPS
200/8
DN/NPS
250/10
DN/NPS
300/12
DN/NPS
400/16
DN/NPS
500/20
DN/NPS
600/24
SPS-TG
5
8
12
18
30
32
SPK-TG
8
12
18
24
36
44
SPM-P-TG
-
-
-
-
-
-
SPM-S-TG
-
-
-
-
-
-
MAXIMUM ALLOWABLE TORQUE IN NM, WHEN OPENING/CLOSING THE SLUICE GATE:
DN/NPS
700/28
DN/NPS
800/32
DN/NPS
900/36
DN/NPS
1000/40
DN/NPS
1200/48
DN/NPS
1400/56
SPS-TG
-
-
-
-
-
-
SPK-TG
50
65
-
-
-
-
SPM-P-TG
-
72
72
113
144
227
SPM-S-TG
-
72
72
113
144
227