INSTALLATION & SERVICE

INDUSTRIAL PUMPS

Models: D-10, G-10

WANNER ENGINEERING, INC.

1204 Chestnut Avenue, Minneapolis, MN  55403
TEL: (612) 332-5681  FAX: (612) 332-6937
TOLL-FREE FAX [US only]: (800) 332-6812

www.hydra-cell.com
email: [email protected]

Содержание Hydra-Cell D-10

Страница 1: ...ICE INDUSTRIAL PUMPS Models D 10 G 10 WANNER ENGINEERING INC 1204 Chestnut Avenue Minneapolis MN 55403 TEL 612 332 5681 FAX 612 332 6937 TOLL FREE FAX US only 800 332 6812 www hydra cell com email sal...

Страница 2: ...lcon Slurry Duty 140 F 60 C consult factory for temperatures above 120 F 49 C Inlet Port D 10 1 inch NPT G 10 1 inch BSPT Discharge Port D 10 3 4 inch NPT G 10 3 4 inch BSPT Shaft Diameter 7 8 inch 22...

Страница 3: ...34 0 36 0 38 0 28 0 2 0 4 0 6 0 8 0 10 0 12 0 0 D G 10 I D G 10S D G 10 E 1450 D G 10 X 200 PSI 14 bar 500 PSI 35 bar 1000 PSI 70 bar 1450 1750 RPM 0 Lift feet of water 0 1 2 3 4 5 6 7 8 200 400 600...

Страница 4: ...50 8 3 0 76 2 4 4 111 8 1 9 48 3 7 3 185 4 3 4 86 4 Inlet 9 5 241 3 3 1 78 7 2 2 55 9 1 1 27 9 2 4 60 9 5 0 127 2 5 63 5 Outlet D 10 3 4 NPT G 10 3 4 BSPT OUT IN D 10 1 NPT G 10 1 BSPT Drain 1 8 NPT...

Страница 5: ...Chemical compatibility problems Hot ambient temperatures above 110 F 43 C Conditions where pump oil may exceed 200 F 93 C because of a combination of hot ambient temperatures hot fluid temperature and...

Страница 6: ...oncollapsing for the inlet lines Minimize fittings elbows valves tees etc Use a suction stabilizer on the inlet Inlet Piping Suction Feed CAUTION When pumping at temperatures above 160 F 71 C use a pr...

Страница 7: ...pump or regulator Route the bypass line to the supply tank or to the suction line as far as possible from the pump to reduce the chance of turbulence and cavitation If the pump may be run for a long...

Страница 8: ...Fluid may come out of this port when the plug is removed Provide an adequate catch basin for fluid spillage if required Fluid will come out of this port when the pump is started so we recommend that y...

Страница 9: ...ulated sediment will drain out CAUTION Do not turn the drive shaft while the oil reservoir is empty Check the inlet pressure or vacuum periodically with a gauge If vacuum at the pump inlet exceeds 7 i...

Страница 10: ...xcept when repairing the hydraulic end 1 Remove Manifold 6 Valve Plate 16 a Remove all nuts 31 and bolts 4 around the manifold Do not remove the two bolts 29 25 or 44 that are installed through the ba...

Страница 11: ...11 D10 991 2400 5 1 04 D G 10 Service Fluid End...

Страница 12: ...ws 41 that secure the valve plate 16 to the cylinder casting 24 Inspect the valve plate in the same manner as you did the manifold a Lift the diaphragm by one edge and turn the pump shaft until the di...

Страница 13: ...ure less than 2 psi a Install the valve plate 16 but without the outlet valves installed or else remove the outlet valves leave the seats installed onto the cylinder housing Tighten the two socket hea...

Страница 14: ...with the valve assemblies installed as outlined above onto the cylinder casting Recheck that the blind hole is over the protruding bolt at the 10 o clock position Install the socket head cap screws 4...

Страница 15: ...15 D10 991 2400 5 1 04 D G 10 Service Hydraulic End...

Страница 16: ...luid End Service Section reinsert a follower screw 17 into the hole in one of the valve plungers 54 Tap the screw lightly with a hammer the plunger 21 should slip off the valve plunger 54 The hydrauli...

Страница 17: ...ll turns then turn it back in again until it is tight against the adjusting plate 61 d Back out the centerbolt exactly 1 4 of a turn e With a plastic mallet or a regular mallet and wooden board to pre...

Страница 18: ...et valves Loss of oil prime in cells because of low oil level Ruptured diaphragm Cavitation Warped manifold from overpressurized system O rings forced out of their grooves from overpressurization Air...

Страница 19: ...wear from high speed operation Cavitation Abrasives in the fluid Valve incompatible with corrosives in the fluid Pump running too fast Loss of Oil External seepage Rupture of diaphragm Frozen pump Di...

Страница 20: ...harge if such parts are returned with transportation charges prepaid to Wanner Engineering Inc 1204 Chestnut Avenue Minneapolis Minnesota 55403 This warranty does not cover 1 The electric motors if an...