background image

25

W&T

RS232 Multi Computer Adapter

Subject to error and alteration

The pinout for the individual ports can be found in the follo-
wing tables.

RS232 input Port A and B with DCE pin functions:

Pin#

Function

Signal

Direction

1

always "on"

DCD

output

2

data out

RxD

output

3

data in

TxD

input

4

handshake in

DTR

input

5

signal GND

GND

GND

6

handshake out

DSR

output

7

not connected

RTS

input

8

handshake out

CTS

output

9

always "off"

RI

output

RS232 output Port C with DTE pin functions:

Pin#

Function

Signal

Direction

1

not connected

DCD

input

2

data in

RxD

input

3

data out

TxD

output

4

handshake out

DTR

output

5

signal GND

GND

GND

6

not connected

DSR

input

7

always "on"

RTS

output

8

handshake in

CTS

input

9

not connected

RI

input

Содержание RS232

Страница 1: ...19 W T RS232 Multi Computer Adapter Subject to error and alteration W T Manual RS232 Multi Computer Adapter Release 1 2 Model 85603...

Страница 2: ...ion Please inform us of any error or misunderstanding you come about so we can identify and eliminate it as soon as possible Carry out your work on or with W T products only to the extent that they ar...

Страница 3: ...red without requiring manual intervention to switch them automatic se lection is on the first come first served principle The interfaces of the Multi Computer Adapter can be configured independently o...

Страница 4: ...4 Display and control elements 26 Configuring the serial ports 27 Serial format 28 Handshake procedure 28 Setting the format DIL switches 29 Modes 30 Manual mode 30 Standard mode 30 Transparent mode 3...

Страница 5: ...panel of the switch indicate which of the two input channels is currently active Supply voltage The supply voltage for the T switch is provided by an integrated switched mode power supply This feature...

Страница 6: ...geous to screw a SUB D plug with body to one port on the T switch and use the attached plug to assist in pulling off the housing cover Wiring assignments The RS232 ports A and B are implemented as SUB...

Страница 7: ...put 3 data in TxD input 4 handshake in DTR input 5 signal GND GND GND 6 handshake out DSR output 7 not connected RTS input 8 handshake out CTS output 9 always off RI output RS232 output Port C with DT...

Страница 8: ...parity or framing errors in running data traffic and can only be cleared explicitly by pressing the Clear key The Clear key resets the T switch and deletes all internal data and error memories Pressi...

Страница 9: ...erface modules to convert the interface type within the device Especially when larger quantities are involved changing over the T switch with other interface modules represents an economical alternati...

Страница 10: ...is output and the hardware handshake output is set to Enable positive level If the T switch receives an XOFF code or detects a block level negative level on the hardware handshake input it stops send...

Страница 11: ...vidual switches can be seen in the following tables handshake S1 data bit S6 hardware handshake off 7 data bit off software handshake ON 8 data bit ON parity S7 S8 no parity X off odd parity off ON ev...

Страница 12: ...rectional connection between Port A and Port C or between Port B and Port C Pressing the key below LED A opens path Port A Port C whereas pressing the key below LED B activates the path Port B Port C...

Страница 13: ...e input from being activated in the middle of a protocol block and thereby a fragmented data record from reaching the receiver In this mode the Multi Computer Adapter supports only the two data lines...

Страница 14: ...up an RS232 port is often accompanied by difficulties since both the pin assignments as well as the transmission parameters need to agree in order to enable errorless data transmission The RS232 Multi...

Страница 15: ...output Hold down the Dump key and then connect the T switch to its power supply After releasing the key the port set on the DIL switches SW4 3 and SW4 4 generates the following output PU 40 6000 SI 0...

Страница 16: ...ion cable PC 2 RS232 COM port PC 1 RS232 COM port Port A 9 pin female connector Port B 9 pin female connector RS232 Multi Computer Adapter 85603 Port C 9 pin male connector Peripheral device with DTE...

Страница 17: ...andshake Optional hardware or XON XOFF handshake Supported signals RxD TxD CTS DTR Operating modes Standard and transparent mode Switchover time Settable switchover time of 5 15 30 120 seconds other v...

Страница 18: ...36 W T RS232 Multi Computer Adapter Declaration of Conformity...

Отзывы: