background image

SUMMARY

OPTIONS SELECTION

Inside the thermostat, there are three selection switches to set at your

preferences.
Temperature in °C or °F, time in 12 or 24 hours and early start function.

TO SET TIME AND DAY

Press on DAY, HOUR and MIN buttons to adjust time and day.

TO RECORD THE      (COMFORT) SETPOINT TEMPERATURE

Select chosen setpoint temperature by using       or       button. Press on

button (2 to 3 seconds) until icon appears on display.

TO RECORD THE     (ECONOMIC) SETPOINT TEMPERATURE

Select chosen setpoint temperature by using        or        button. Press

on     button (2 to 3 seconds) until icon appears on display.

TO RECORD THE       (VACATION) SETPOINT TEMPERATURE

Select chosen setpoint temperature by using       or       button. Press on

button (2 or 3 seconds) until icon appears on display.

OPERATING MODES

To select an operating mode, use MODE button.

AUTO :

Runs the program.       or       shows temperature set
ting and can override temporarily your programming up 

to the next program.

MAN :

Maintains the selected temperature.      or       changes 
the temperature setting.

MODEL TSTAT (240 VAC)

u

u

u

u

u

u

CHARACTERISTICS

• Model :

TSTAT

• Supply :

240 VAC 50/60 Hz

• Load :

16 A max. (resistive only)

• Power :

3840 W (NI) @ 240 VCA

• Approvals :

CEE

• Display range :

0 to 60 °C (32 to 140 °F)

• Setting range :

5 to 40 °C (40 to 104 °F)

• Comfort default setting :

28 °C (82 °F)

• Econo default setting :

18 °C (64 °F)

• Vacation default setting :

10 °C (50 °F)

• Storage :

-20 to 50 °C (-4 to 120 °F)

WARRANTY

WARMUP plc  ONE  (1) YEAR LIMITED WARRANTY

This product is warranted against material defects and workmanship in normal

use for a period of one year, from the date of the original purchase from author-

ized dealers. During this period, WARMUP plc will repair or replace

the product with a new or of equivalent quality at WARMUP's option, without

charge, any product proven defective in normal use.

Warranty does not cover transportation costs. Nor does it cover a product sub-

jected to misuse or accidental damage. This warranty does not cover the cost of

installation, removal or reinstallation.

This limited warranty is in lieu of all other warranties, obligations or liabilities

expressed or implied by the company. In no event shall WARMUP plc 

be liable for consequential or incidental damages resulting from installation of

this product. 
The defective product and the original sale receipt must be returned to the origi-

nal dealer or shipped pre-paid, insured and addressed to :

WARMUP plc, Unit 1 Rowley Industrial Park, Roslin Rd., Acton, London, W3 8BH

 

If you have any questions concerning the installation or programming of this

product, please call our technical helpline  on 

0845 345 2288

INSTALLATION

This  thermostat  is  designed  to  control  floor  electric  heating  systems.  The

resistive load must not exceed 3840 watts (NI) @ 240 VAC (16 A). Electricians or

experienced technicians should install the thermostat. 
This thermostat is designed to be used with a self-protected heating system

equipped with  a residual current device (RCD or RCCD).

PARTS INCLUDED
- One (1) TSTAT  (240 VAC) thermostat

- One (1) temperature sensor with a 4.6 meter extension.       

TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER

PANEL TO AVOID ELECTRICAL SHOCK

. Keep air vents of the thermostat

clean and free from obstructions.

1) Connecting wires and mounting thermostat

Connect to L1 and N5 (terminals) the line wires (240 VAC) that come from the

breaker and connect the load wires to L2 and N4 (terminals) . See schematic

diagram. Push the excess wire back into the electrical box to prevent interfer-

ence with the thermostat. Secure the thermostat using two (2) 

screws.

Once the thermostat is properly installed, return power to the heating system.

S upply

Load

Live 
R E D 
or B R OWN

Neutral 
B LUE
or B LAC K

Neutral 
B LUE

Live 
B R OWN

E

le

ct

ri

ca

l B

o

x

Power-up

To power up :

When power is applied for the first time, the

display  must  show  the  time  0:00,  the  floor

temperature and the manual mode icon (       ).

Other information might show up on the dis-

play  if  installation  is  defective  or  does  not

comply with the instructions.

The message L0 or HI will appear on the dis-

play if the temperature sensor is defective or

the temperature is below 0 °C (32 °F) or high-

er than 60 °C (140 °F). Also, if the LO message is dis-

played, the heating indicator will be present on display

and the relay will be closed (current going in the load).

2) Connecting temperature sensor wire

Connect the temperature sensor wire to the S1 and S2 terminals situated at the

far right of the connector of the thermostat (no polarity needs to be respected).

The sensing probe should be placed in a representa-

tive heat area for maximum system performance. The

sensing probe should be centered between the wires

in the mat. The temperature sensor wire cannot cross

any heater wires and the sensing probe must not be

directly or adjacent to a heating wire.

ALL ELECTRICAL WORK MUST CONFORM TO THE CURRENT IEE WIRING

REGULATIONS. 

E arth 
G R E E N

2 x E arth 
G R E E N/
Y E LLOW

Отзывы: