SUMMARY
OPTIONS SELECTION
Inside the thermostat, there are three selection switches to set at your
preferences.
Temperature in °C or °F, time in 12 or 24 hours and early start function.
TO SET TIME AND DAY
Press on DAY, HOUR and MIN buttons to adjust time and day.
TO RECORD THE (COMFORT) SETPOINT TEMPERATURE
Select chosen setpoint temperature by using or button. Press on
button (2 to 3 seconds) until icon appears on display.
TO RECORD THE (ECONOMIC) SETPOINT TEMPERATURE
Select chosen setpoint temperature by using or button. Press
on button (2 to 3 seconds) until icon appears on display.
TO RECORD THE (VACATION) SETPOINT TEMPERATURE
Select chosen setpoint temperature by using or button. Press on
button (2 or 3 seconds) until icon appears on display.
OPERATING MODES
To select an operating mode, use MODE button.
AUTO :
Runs the program. or shows temperature set
ting and can override temporarily your programming up
to the next program.
MAN :
Maintains the selected temperature. or changes
the temperature setting.
MODEL TSTAT (240 VAC)
u
u
u
u
u
u
CHARACTERISTICS
• Model :
TSTAT
• Supply :
240 VAC 50/60 Hz
• Load :
16 A max. (resistive only)
• Power :
3840 W (NI) @ 240 VCA
• Approvals :
CEE
• Display range :
0 to 60 °C (32 to 140 °F)
• Setting range :
5 to 40 °C (40 to 104 °F)
• Comfort default setting :
28 °C (82 °F)
• Econo default setting :
18 °C (64 °F)
• Vacation default setting :
10 °C (50 °F)
• Storage :
-20 to 50 °C (-4 to 120 °F)
WARRANTY
WARMUP plc ONE (1) YEAR LIMITED WARRANTY
This product is warranted against material defects and workmanship in normal
use for a period of one year, from the date of the original purchase from author-
ized dealers. During this period, WARMUP plc will repair or replace
the product with a new or of equivalent quality at WARMUP's option, without
charge, any product proven defective in normal use.
Warranty does not cover transportation costs. Nor does it cover a product sub-
jected to misuse or accidental damage. This warranty does not cover the cost of
installation, removal or reinstallation.
This limited warranty is in lieu of all other warranties, obligations or liabilities
expressed or implied by the company. In no event shall WARMUP plc
be liable for consequential or incidental damages resulting from installation of
this product.
The defective product and the original sale receipt must be returned to the origi-
nal dealer or shipped pre-paid, insured and addressed to :
WARMUP plc, Unit 1 Rowley Industrial Park, Roslin Rd., Acton, London, W3 8BH
If you have any questions concerning the installation or programming of this
product, please call our technical helpline on
0845 345 2288
INSTALLATION
This thermostat is designed to control floor electric heating systems. The
resistive load must not exceed 3840 watts (NI) @ 240 VAC (16 A). Electricians or
experienced technicians should install the thermostat.
This thermostat is designed to be used with a self-protected heating system
equipped with a residual current device (RCD or RCCD).
PARTS INCLUDED
- One (1) TSTAT (240 VAC) thermostat
- One (1) temperature sensor with a 4.6 meter extension.
TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER
PANEL TO AVOID ELECTRICAL SHOCK
. Keep air vents of the thermostat
clean and free from obstructions.
1) Connecting wires and mounting thermostat
Connect to L1 and N5 (terminals) the line wires (240 VAC) that come from the
breaker and connect the load wires to L2 and N4 (terminals) . See schematic
diagram. Push the excess wire back into the electrical box to prevent interfer-
ence with the thermostat. Secure the thermostat using two (2)
screws.
Once the thermostat is properly installed, return power to the heating system.
S upply
Load
Live
R E D
or B R OWN
Neutral
B LUE
or B LAC K
Neutral
B LUE
Live
B R OWN
E
le
ct
ri
ca
l B
o
x
Power-up
To power up :
When power is applied for the first time, the
display must show the time 0:00, the floor
temperature and the manual mode icon ( ).
Other information might show up on the dis-
play if installation is defective or does not
comply with the instructions.
The message L0 or HI will appear on the dis-
play if the temperature sensor is defective or
the temperature is below 0 °C (32 °F) or high-
er than 60 °C (140 °F). Also, if the LO message is dis-
played, the heating indicator will be present on display
and the relay will be closed (current going in the load).
2) Connecting temperature sensor wire
Connect the temperature sensor wire to the S1 and S2 terminals situated at the
far right of the connector of the thermostat (no polarity needs to be respected).
The sensing probe should be placed in a representa-
tive heat area for maximum system performance. The
sensing probe should be centered between the wires
in the mat. The temperature sensor wire cannot cross
any heater wires and the sensing probe must not be
directly or adjacent to a heating wire.
ALL ELECTRICAL WORK MUST CONFORM TO THE CURRENT IEE WIRING
REGULATIONS.
E arth
G R E E N
2 x E arth
G R E E N/
Y E LLOW