31
1.6 Potential problems and how to tackle them
Kind
of
operating
problem
Possible reasons
Solution
Odour formation
Curing of the applied pre-
ventive lacquer.
Steaming oil remains.
Operate the fire-place on a
low heating level according
to the instructions manual
for a few hours. Then heat
up for maximal perform-
ance for a few hours.
Too little heating per-
formance
•
We chose too little per-
formance
•
Chimney
draught
is
slight
•
Have the heating re-
quirement of the room
examined by an expert
•
Chimney draught shall
be at least 12 Pa, max.
for a short time 18 Pa.
•
Check the tightness of
your chimney and also
that the doors of other
fire-places leading to
the same chimney are
closed
and
sealed
properly. Make sure
that
the
chimney-
cleaning
joints
are
sealed properly.
•
Too long and leaky
smoke tube
•
All the smoke tube
joints must be well
sealed and fireproof-
isolated
•
Leakage at the door
glass
•
Check the sealing,
close the door properly.
May have to have the
tightening
flap
re-
newed.
•
Usage of wet wood.
•
Use well dried wood
only.
Actions to be in chimney fire
Chimney fire may occur upon the improper cleaning of the chimney, the use of in-
appropriate fuels (e.g. excessively wet wood) or the inadequate setting of the burn-
ing air. In such cases, close the burning air at the fire, and call the fire service.
Never try to extinguish the fire with water!
Содержание 108 80 VISION
Страница 10: ...10 Ausmauerung Bild 2 Bild 3 Bild 4 Bild 5 Bild 6 Bild 7 Umlenkplatte...
Страница 16: ...16...
Страница 21: ...21...
Страница 22: ...22...
Страница 66: ...66 Muratura parafiamma fig 2 fig 3 fig 4 fig 5 fig 6 fig 7...
Страница 92: ...92 3 M szaki adatok 3 1 M retek TYP 108 80 Vision Nero S ly brutt nett 225 203 kg...