Waltons 01GRODB0808-V2 Скачать руководство пользователя страница 5

P 5

Please retain product label and instructions for future reference

             

Step 7

30mm
16mm

Opening Window

Fixed Window

30mm 

screw

30mm 

screw

16mm 

screw

30mm 

screw

Place the window strip 11mm above 
the window gap in the window panel 
and fix with 3x30mm screws.

If you would like the windows to be 
opening use the butt hinges to 
attach the opening window strip 
and the opening window together.
Use 30mm screws to fix the butt 
hinge to the Window Strip and 
16mm screws to fix it to the 
Opening Window.

If you want to fix the opening 
windows, instead of fixing butt 
hinges to the opening window, 
use 4x30mm screws to attach 
the opening windows to the 
window panel as shown in the 
diagram.

3x30mm Screws

*SCREW COUNT PER WINDOW

6x30mm Screws
6x16mm Screws

4x30mm Screws

Lay the window panel down on a flat surface 

before fitting the window strip and window.

22

16

16

11

11

Step 8

Place floors on a firm and 

level base, ensure base has 

suitable drainage  free from 

areas where standing water 

can collect.  (see front page 

on base requirements).  

Ensure floors are flush to 

each other and fix using 

8x50mm screws. Alternate 

fixing positions along the 

length of the floors.

*Note
Floors do not connect 
by a T & G joint

8x50mm screws

1

1

50mm 

screw

Pre drill 

hole

Step 9

Fix the corners with 3x 
50mm screw a shown in 
diagram.

Position the panels so there is 
equal spacing between the floor 
and cladding on all 4 sides

3x50mm screws

1

Plain and window panel 

can be positioned on 

either side.

8

50mm 

screw

Pre drill 

hole

Содержание 01GRODB0808-V2

Страница 1: ...r guarantee and ensure longevity of the product it is ESSENTIAL the building is treated with a wood preserver within the first three months of assembly and thereafter in accordance with the manufactur...

Страница 2: ...n Panel Small Roof Qty 2 Large Roof Qty 2 Window Qty 2 12 13 14 15 16 17 18 19 20 Gable Strip 12x121x2300mm Qty 2 Cover Trim 12x25x1810mm Qty 4 Window Strip 12x45x1055mm Qty 2 Door Strip 12x45x1764mm...

Страница 3: ...ensure they are level at the top then fix together using 60mm screws Stagger the screws so they do not collide 60mm screw Pre drill hole 2 4 Line a Gable Strip up to the assembled gable ensuring the b...

Страница 4: ...rews Lay the Plain Back Panel and the remaining Gable Top on a level floor place the gable top on top of the plain back panel ensure they are level at the top then fix together using 60mm screws Stagg...

Страница 5: ...dow panel as shown in the diagram 3x30mm Screws SCREW COUNT PER WINDOW 6x30mm Screws 6x16mm Screws 4x30mm Screws Lay the window panel down on a flat surface before fitting the window strip and window...

Страница 6: ...e gable top rafters Fix panels into position using 4x30mm screws from the top of panel straight into the rafter Pre drill holes before hand Ensure the larger over hang on both panels are facing each o...

Страница 7: ...sing felt tacks at 100mm intervals Step 14 24 Step 15 Use 3x30mm screws to fix each cover trim 12x30mm screws 13 13 13 Step 16 Fit fascia boards to the front and the back of building using 3x40mm scre...

Страница 8: ...h the pre drilled holes before fixing Align Lock keep with lock and fix with screws provided Fig 2 Place door handle bar through the lock as in diagram fix door handle onto bar with the flat headed gr...

Страница 9: ...al the turn button catches the master door 2x30mm black screws These turn buttons help to keep your doors straight during high levels and low levels of moisture content in the air 30mm screw Pre drill...

Отзывы: