Walther E-Boxx EV Simulator Скачать руководство пользователя страница 11

Operating instruction and technical description 

EV tester type 1 and type 2 - 2.0 

©

 Walther-Werke Ferdinand Walther GmbH 

 

 

 

 

 

 

 

Seite 11 von 12

 

5    Troubleshooting 

Error, fault 

Cause 

Remedy 

Measuring device  
of EV simulator  
does not react 

Batteries are empty 

 

Exchange  batteries  of  measuring  device  (see 
maintenance). 

Attach the device correctly. 

EV simulator  
does not react  

Voltage supply is missing 

 

 

Plugs are not inserted correctly 

 
Switch positions are wrong 

Check voltage supply of charging infrastructure 

Check pre-fuses 

                           
 
Check plug connection 

                                                                       
Check switch positions 

RCD does not trigger;  
LED is shining 
permanently while 
pushbutton FI/RCD is 
pressed 

Plugs are not inserted correctly 

 
RCD does not work correctly or 
is not available. 

Check plug connection  

Release pushbutton immediately 

Check RCD and switch on again  

Check wiring of the installation 

The oscilloscope 
connected to the BNC 
female jack delivers no 
signal 

BNC plug is not inserted  
correctly  

Switch positions are wrong 

Check switch positions B,C,D  

Check position of switch type 1 – type 2  

Check BNC plug 

Check oscilloscope settings 

Charging device does 
not react to simulation 

  

Plug is not inserted correctly 

Switch type 1 – type 2 in wrong 
position 

Switch PE is Off 

PE is interrupted 

Check connection. Only one connection may be 
occupied.  

Check position of switch type 1 – type 2 
 
Switch on the PE switch 

Check PE 

No line simulation  
possible 
 

Measuring line defective or  
not available 
 

Switch positions during 
simulation of power values are 
wrong 
 

Use measuring line  

Switch on the "simulation power values" switch 
 
More than one switch (13, 20, 32 63 A) is switched 
on 

Wrong measuring 
values with the coding 
resistor 

 

Measuring line inserted 
 
Switch "Simulation power  
values" wrong 

 

Remove measuring line 

Switch off the "simulation power values" switch 
 

Faulty resistor inside the cable 

Содержание E-Boxx EV Simulator

Страница 1: ...nstruction and technical description EV Simulator for charging devices with charging plug charging coupler charging cable type 1 and type 2 as service case Photo EV simulator tester with enclosed measuring line by ...

Страница 2: ...dling 4 2 Features of the EV simulators 4 3 Measuring of built in resistances inside plug type 2 4 4 Ampacity simulation of resistances inside plug type 2 4 5 Measuring of built in resistances inside plug type 1 4 6 Checking the PE connection between PWM and vehicle 4 7 Simulation of a fault by means of a switchable fault current 4 8 Simulation of vehicle status B C D and display of charging volta...

Страница 3: ... these recommendations helps minimizing the risk of health damages injuries property damages and production downtimes Please see that these precautionary measures will be observed it s in your own interest Train and instruct the operating personnel thoroughly The system must only be operated and opened by trained technical staff Store these instructions in a way that they are clearly visible and w...

Страница 4: ... checking the interlock s switching function Ampacity simulation of a charging cable Checking the PE connection between PWM and vehicle Simulation of a leakage current 30 mA from L1 to PE Simulation of vehicle status B C D and indication of charging voltage via LEDs CP test jack for PWM signal The device simulates both faults which can occur during normal use and different operating conditions of ...

Страница 5: ...of up to 6 A can be connected 3 2 2 Hardware configuration Perform the following steps consecutively Remove all parts of the packaging carefully Avoid damaging Check the device thoroughly regarding transport damages and other damages Supplier and forwarder have to be informed immediately about each damage Check whether all parts have been delivered completely If applicable do also consider spare p...

Страница 6: ... even cause a short circuit Toggling between the two charging sockets is made by the changeover switch in the middle of the operator panel The plug should only be withdrawn when the electric vehicle is switched off EV status B C and D Aus OFF The tester has no integrated interlock 4 2 Switching on the EV simulator The EV simulator is switched on by inserting the charging plug into the charging soc...

Страница 7: ...o measured values are indicated the plug has to be checked Attention The integrated measuring device is for resistance measuring only and should therefore only be switched on shortly for measuring the resistances will result in a longer battery durability Under no circumstances leave it switched on during other test procedures with applied voltage 4 4 Simulation of resistors ampacity inside plug t...

Страница 8: ... only one switch at a time may be switched on This simulation is only possible and permissible with type 2 The measuring line may only be used for this purpose Charging an electric vehicle with this measuring line is not permissible not possible Photo Switch for simulating the ampacity of the charging cable 4 5 Measuring of built in resistors inside type 1 plug Acc to SAE J1772 the type 1 plug con...

Страница 9: ...In switch position Ein ON the PE is connected in switch position Aus OFF it is interrupted Thus the connection between PE and CP on the vehicle side is interrupted and the charging process should be switched off by the charging device Now the charging device should no longer react to operating the switches Status EV signal CP B C or D 4 7 Simulation of a fault by means of switchable fault current ...

Страница 10: ...ehicle is connected to the charging device and is ready to be charged PWM signal 9 V By additionally operating switch C i e B and C the electric vehicle requests charging current and it is switched on by the charging device Please note that no thereby no charging power is withdrawn The electric vehicle which is simulated by the EV tester would be charged now PWM signal 6 V By operating switch D in...

Страница 11: ...ck wiring of the installation The oscilloscope connected to the BNC female jack delivers no signal BNC plug is not inserted correctly Switch positions are wrong Check switch positions B C D Check position of switch type 1 type 2 Check BNC plug Check oscilloscope settings Charging device does not react to simulation Plug is not inserted correctly Switch type 1 type 2 in wrong position Switch PE is ...

Страница 12: ... to be separated from the charging device prior to any maintenance work Maintenance work may only be carried out by trained specialised staff To avoid increased contact resistances the contacts on the charging sockets of the EV tester and on the plugs of the charging cable and the measuring line have to be checked 7 General technical specifications Length approx 360 mm Width approx 310 mm Height a...

Отзывы: